Ultrasound Cyclo-Plasty in Patients with Glaucoma: 1-Year Results from a Multicentre Prospective Study

被引:35
作者
Giannaccare, Giuseppe [1 ]
Vagge, Aldo [2 ]
Sebastiani, Stefano [1 ]
Urbini, Lara E. [3 ]
Corazza, Paolo [2 ]
Pellegrini, Marco [1 ]
Carmassi, Luciana [3 ]
Bergamini, Fulvio [3 ]
Traverso, Carlo E. [2 ]
Campos, Emilio C. [1 ]
机构
[1] Univ Bologna, S Orsola Malpighi Univ Hosp, DIMES, Ophthalmol Unit, Bologna, Italy
[2] Univ Genoa, Eye Clin, DiNOGMI, Genoa, Italy
[3] Ist Auxol Italiano, IRCCS Fdn, Sci Inst Capitanio Hosp, Dept Ophthalmol, Milan, Italy
关键词
Glaucoma; Ultrasound cyclo-plasty; High-intensity focused ultrasound; Intraocular pressure; Ciliary body; INTENSITY FOCUSED ULTRASOUND; REFRACTORY GLAUCOMA; CILIARY BODY; DEVICE; LASER; CYCLOPHOTOCOAGULATION; CYCLOCOAGULATION;
D O I
10.1159/000487953
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to evaluate the safety and efficacy of ultrasound cyclo-plasty (UCP) for reducing intraocular pressure (IOP) in patients with glaucoma. Methods: This is a multicentre prospective study conducted in 3 Italian glaucoma centres. UCP was performed by EyeOP1, which delivers ultrasound beams using 6 piezoelectric transducers activated for 4/6 s (first generation) or 8 s (second generation). Primary outcomes were the mean IOP reduction and the rates of success after 1 year. Secondary outcomes were the mean IOP reduction at each follow-up, and the reduction of the number of hypotensive medications. Results: In total, 49 eyes from 47 patients were treated. One year postoperatively, the mean IOP had decreased from 27.7 +/- 9.2 to 19.8 +/- 6.9 mm Hg (p < 0.001), and the mean number of hypotensive drops and tablets had decreased from 3.2 and 0.5 to 2.3 and 0.2, respectively (p < 0.05). Postoperative IOP reduction was significantly related to preoperative IOP (r(2) = 0.5034; p < 0.0001). Second-generation probes determined a significantly higher IOP reduction (p < 0.05). Qualified success was achieved in 25 eyes (51.1%) and complete success in 21 (42.9%), while failure was recorded in 12 (24.5%). Conclusions: UCP is safe and effective for reducing IOP. The procedure determines a greater IOP reduction in patients with higher preoperative IOP. Second-generation probes improve outcomes without detrimental effects on safety. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:137 / 142
页数:6
相关论文
共 23 条
[1]  
Aptel F, 2016, ACTA OPHTHALMOL, V94, pe268, DOI [10.1111/aos.12913, 10.1111/j.1755-3768.2016.0447]
[2]   Treatment of glaucoma with high intensity focused ultrasound [J].
Aptel, Florent ;
Lafon, Cyril .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2015, 31 (03) :292-301
[3]   SHORT- AND LONG-TERM EFFECTS ON THE CILIARY BODY AND THE AQUEOUS OUTFLOW PATHWAYS OF HIGH-INTENSITY FOCUSED ULTRASOUND CYCLOCOAGULATION [J].
Aptel, Florent ;
Begle, Aurelie ;
Razavi, Arash ;
Romano, Fabrice ;
Charrel, Thomas ;
Chapelon, Jean-Yves ;
Denis, Philippe ;
Lafon, Cyril .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (09) :2096-2106
[4]   Treatment of refractory open-angle glaucoma using ultrasonic circular cyclocoagulation: a prospective case series [J].
Aptel, Florent ;
Dupuy, Caroline ;
Rouland, Jean-Francois .
CURRENT MEDICAL RESEARCH AND OPINION, 2014, 30 (08) :1599-1605
[5]   Miniaturized High-Intensity Focused Ultrasound Device in Patients with Glaucoma: A Clinical Pilot Study [J].
Aptel, Florent ;
Charrel, Thomas ;
Lafon, Cyril ;
Romano, Fabrice ;
Chapelon, Jean-Yves ;
Blumen-Ohana, Esther ;
Nordmann, Jean-Philippe ;
Denis, Philippe .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) :8747-8753
[6]   Histologic Effects of a New Device for High-Intensity Focused Ultrasound Cyclocoagulation [J].
Aptel, Florent ;
Charrel, Thomas ;
Palazzi, Xavier ;
Chapelon, Jean-Yves ;
Denis, Philippe ;
Lafon, Cyril .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (10) :5092-5098
[7]   Micropulse versus continuous wave transscleral diode cyclophotocoagulation in refractory glaucoma: a randomized exploratory study [J].
Aquino, Maria Cecilia D. ;
Barton, Keith ;
Tan, Anna Marie W. T. ;
Sng, Chelvin ;
Li, Xiang ;
Loon, Seng Chee ;
Chew, Paul T. K. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 (01) :40-46
[8]   DEVELOPMENT OF A MINIATURIZED HIFU DEVICE FOR GLAUCOMA TREATMENT WITH CONFORMAL COAGULATION OF THE CILIARY BODIES [J].
Charrel, Thomas ;
Aptel, Florent ;
Birer, Alain ;
Chavrier, Francoise ;
Romano, Fabrice ;
Chapelon, Jean-Yves ;
Denis, Philippe ;
Lafon, Cyril .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (05) :742-754
[9]   Endoscopic photocoagulation of the ciliary body for treatment of refractory glaucomas [J].
Chen, J ;
Cohn, RA ;
Lin, SC ;
Cortes, AE ;
Alvarado, JA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) :787-796
[10]  
De Roetth A Jr, 1965, Trans Am Ophthalmol Soc, V63, P189