The Dual-Current Control Strategy of Grid-Connected Inverter With LCL Filter

被引:64
作者
Guan, Yuanpeng [1 ]
Wang, Yu [2 ]
Xie, Yunxiang [1 ]
Liang, Yi [1 ]
Lin, Anna [1 ]
Wang, Xuemei [1 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510641, Guangdong, Peoples R China
[2] Guangdong Univ Technol, Sch Automat, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Anti-interference capability; dual-current control strategy; grid-connected inverter with LCL filter (GCI-LCL); resonance suppression; stability margin; DESIGN; ROBUSTNESS; DELAY;
D O I
10.1109/TPEL.2018.2869625
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the renewable energy generation systems, the grid-connected inverter with LCL filter (GCI-LCL) is an important device to realize dc-ac power conversion and connect the distributed power generation system and power grid. However, the resonance problems of the LCL filter may bring instability to GCI-LCL. Besides, the grid impedance and the time delay in digital controllers also have a harmful influence on the stability of GCI-LCL. To solve these problems, a dual-current active damping control strategy based on the inverter-side current and grid-connected current feedback for GCI-LCL is proposed in this paper, and the systematic parameters design process is investigated. Compared with the conventional damping strategies, a resonance suppression for the LCL filter, a larger stability margin, and a better anti-interference capability in a weak grid can be achieved under the proposed strategy. In addition, by analyzing the active damping effect of the proposed strategy, a simplified model in a low-frequency band for GCI-LCL is proposed to enhance the anti-interference capability in the weak grid and simplify the parameters design process. Finally, a GCI-LCL prototype is constructed and the experiment results verify the correctness and feasibility of the analysis and proposed strategy.
引用
收藏
页码:5940 / 5952
页数:13
相关论文
共 32 条
[1]   Analysis and design of split-capacitor resistive-inductive passive damping for LCL filters in grid-connected inverters [J].
Balasubramanian, Arun Karuppaswamy ;
John, Vinod .
IET POWER ELECTRONICS, 2013, 6 (09) :1822-1832
[2]   Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping [J].
Bao, Chenlei ;
Ruan, Xinbo ;
Wang, Xuehua ;
Li, Weiwei ;
Pan, Donghua ;
Weng, Kailei .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (03) :1239-1253
[3]   Robust Active Damping Methods for LCL Filter-Based Grid-Connected Converters [J].
Ben Said-Romdhane, Marwa ;
Naouar, Mohamed Wissem ;
Slama-Belkhodja, Ilhem ;
Monmasson, Eric .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (09) :6739-6750
[4]   A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Liserre, Marco ;
Blaabjerg, Frede ;
Bak, Claus Leth .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) :54-69
[5]   Optimal Design of High-Order Passive-Damped Filters for Grid-Connected Applications [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Blaabjerg, Frede ;
Liserre, Marco ;
Bak, Claus Leth .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (03) :2083-2098
[6]   Full-State Feedback Equivalent Controller for Active Damping in LCL-Filtered Grid-Connected Inverters Using a Reduced Number of Sensors [J].
Busada, Claudio A. ;
Gomez Jorge, Sebastian ;
Solsona, Jorge A. .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (10) :5993-6002
[7]   A Time Delay Compensation Method Based on Area Equivalence For Active Damping of an LCL-Type Converter [J].
Chen, Chen ;
Xiong, Jian ;
Wan, Zhiqiang ;
Lei, Ji ;
Zhang, Kai .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (01) :762-772
[8]   Value of Distribution Network Reconfiguration in Presence of Renewable Energy Resources [J].
Dorostkar-Ghamsari, Mohammad Reza ;
Fotuhi-Firuzabad, Mahmud ;
Lehtonen, Matti ;
Safdarian, Amir .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (03) :1879-1888
[9]  
Escobar G, 2012, IEEE IND ELEC, P3406, DOI 10.1109/IECON.2012.6389352
[10]   Weighted Average Current Control in a Three-Phase Grid Inverter With an LCL Filter [J].
He, Ning ;
Xu, Dehong ;
Zhu, Ye ;
Zhang, Jun ;
Shen, Guoqiao ;
Zhang, Yangfan ;
Ma, Jie ;
Liu, Changjin .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2785-2797