Pulse Oximetry in the Diagnosis of Acute Heart Failure

被引:5
|
作者
Masip, Josep [1 ]
Gaya, Maria [1 ]
Paez, Joaquim [1 ]
Betbese, Antoni [1 ]
Vecilla, Francisco [1 ]
Manresa, Ruben [1 ]
Ruiz, Pilar [1 ]
机构
[1] Univ Barcelona, Unidad Cuidados Intens, Hosp St Joan Despi Moises Broggi, Consorci Sanitari Integral, Barcelona 08970, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2012年 / 65卷 / 10期
关键词
Pulse oximetry; Oxygen saturation; Acute heart failure; Myocardial infarction; ACUTE MYOCARDIAL-INFARCTION; NATRIURETIC PEPTIDE; OXYGEN-THERAPY; SLEEP-APNEA; HYPOXEMIA; GUIDELINES; PATIENT;
D O I
10.1016/j.rec.2012.02.021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Oxygen saturation by pulse oximetry is commonly used for monitoring critical patients, but its utility as a diagnostic marker of acute heart failure has not been assessed. This study analyzed the diagnostic role of oxygen saturation by pulse oximetry in a series of patients with acute myocardial infarction. Methods: In a prospective observational cohort study of 220 consecutive patients with acute myocardial infarction, data collection included baseline oxygen saturation by pulse oximetry (without oxygen), physiologic measurements, Killip class and data from portable chest radiography, recorded at the same hour on each of the first three days after admission. Patients were followed up for one year. Results: There were 612 assessments. Baseline oxygen saturation by pulse oximetry decreased progressively in relation to the presence and the severity of acute heart failure assessed by Killip classes 1 to 3 (mean: 95, 92 and 85, respectively; P<.001) or by radiology score 0 to 4 (95, 94, 92, 89 and 83, respectively; P<.001), with a correlation coefficient of 0.66 and 0.63, respectively. Receiver operating characteristic curves disclosed the cut-off of oxygen saturation by pulse oximetry <93 to have the greatest area, with a sensitivity of 65%, specificity 90%, and overall test accuracy 83%. Patients grouped according to lowest oxygen saturation by pulse oximetry showed significantly different rates of one-year mortality or rehospitalization for heart failure. Conclusions: Baseline oxygen saturation by pulse oximetry is useful in establishing the diagnosis and severity of heart failure in acute settings such as myocardial infarction and may have prognostic implications. The diagnosis may be suspected when baseline oxygen saturation by pulse oximetry is <93. (C) 2012 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L. All rights reserved.
引用
收藏
页码:879 / 884
页数:6
相关论文
共 50 条
  • [21] Pulse oximetry for the diagnosis of vascular limb trauma
    Kwasnicki, Richard Mark
    Burgin, Joseph
    Paton, Christopher
    Hettiaratchy, Shehan
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2022, 75 (09) : 3182 - 3189
  • [22] The Impact of Thoracentesis On Postprocedure Pulse Oximetry
    Taylor, Trevor M.
    Radchenko, Christopher
    Sanchez, Trinidad M.
    Shepherd, Ray W.
    Kang, Le
    Shojaee, Samira
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2021, 28 (03) : 192 - 200
  • [23] Accuracy and precision of buccal pulse oximetry
    De Jong, Marla J.
    Schmelz, Joseph
    Evers, Karen
    Bradshaw, Patricia
    McKnight, Kathleen
    Bridges, Elizabeth
    HEART & LUNG, 2011, 40 (01): : 31 - 40
  • [24] Clinical approaches to the diagnosis of acute heart failure
    Wong, Graham C.
    Ayas, Najib T.
    CURRENT OPINION IN CARDIOLOGY, 2007, 22 (03) : 207 - 213
  • [25] Acute heart failure: differential diagnosis and treatment
    Marini, Marco
    Manfredi, Roberto
    Battistoni, Ilaria
    Francioni, Matteo
    Matassini, Maria Vittoria
    Pongetti, Giulia
    Angelini, Luca
    Shkoza, Matilda
    Bontempo, Alessandro
    Belfioretti, Leonardo
    Perna, Gian Piero
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2023, 25 : C276 - C282
  • [26] Biomarkers for Diagnosis and Prognosis of Acute Heart Failure
    Rajiv Choudhary
    Salvatore Di Somma
    Alan S. Maisel
    Current Emergency and Hospital Medicine Reports, 2013, 1 (2) : 133 - 140
  • [27] Nonpharmacological Management of Acute Heart Failure
    Placido, Rui
    Mebazaa, Alexandre
    REVISTA ESPANOLA DE CARDIOLOGIA, 2015, 68 (09): : 794 - 802
  • [28] Pulse Oximetry Screening for Detecting Critical Congenital Heart Disease in Neonates
    Jain, Deepshikha
    Jain, Manish
    Lamture, Yashwant
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (12)
  • [29] Pulsus paradoxus indicating heart failure in paroxysmal supraventricular tachycardia: easy detection by pulse oximetry
    B. Frey
    Intensive Care Medicine, 1999, 25 : 333 - 334
  • [30] Pulse oximetry: a new way of determining the heart rate in chicken embryos
    Lewin, R
    Dorner, M
    Tonhardt, H
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1997, 434 (05): : 639 - 641