An evaluation of the GlideScope®, a new video laryngoscope for difficult airways:: A manikin study

被引:53
作者
Benjamin, F. J.
Boon, D.
French, R. A.
机构
[1] Princess Wales Hosp, Bridgend CF3 1RQ, Wales
[2] Christchurch Hosp, Dept Anaesthesia, Christchurch, New Zealand
关键词
AIRWAY OBSTRUCTION; ANAESTHESIA GENERAL; PATIENT SIMULATION; LARYNGOSCOPE; FIBREOPTIC; INTUBATION INTRATRACHEAL;
D O I
10.1017/S0265021506000147
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background and objectives: The GlideScope (R) is a new video laryngoscope. The aim of our study was to assess its use compared to a Macintosh blade in airway scenarios on the Airman (TM) airway simulator. The scenarios were: 'normal' or resting state of the manikin, pharyngeal obstruction, cervical rigidity and tongue oedema. Methods: Thirty anaesthetists from the Christchurch Anaesthetic Department attempted to pass a bougie or stylet through the vocal cords of the manikin with a size 3 Macintosh blade, then the GlideScope. View at laryngoscopy, ease of 'intubation' and whether they thought the GlideScope would be useful in clinical practice were recorded. Results: Forty three percent (P = 0.02) found an improved view with the GlideScope in the pharyngeal obstruction scenario. In the other scenarios there was no significant difference in view. Reportage of ease of intubation showed no statistical difference in any scenarios. However, 93% of anaesthetists considered having the GlideScope would be useful if faced clinically with one or more of the studied scenarios. Conclusions: The GlideScope improved the view in one of three difficult airway situations when used by anaesthetists with no formal training in its use. No single airway device offers a solution to all scenarios, however, we consider that the GlideScope is a useful addition to the range of difficult airway devices available.
引用
收藏
页码:517 / 521
页数:5
相关论文
共 10 条
[1]   Tracheal intubation using a Macintosh laryngoscope or a GlideScope® in 15 patients with cervical-spine immobilization [J].
Agrò, F ;
Barzoi, G ;
Montecchia, F .
BRITISH JOURNAL OF ANAESTHESIA, 2003, 90 (05) :705-706
[2]  
Cooper RM, 2003, CAN J ANAESTH, V50, P611, DOI 10.1007/BF03018651
[3]  
Doyle DJ, 2004, CAN J ANAESTH, V51, P95
[4]   Awake intubation using the GlideScope® video laryngoscope:: initial experience in four cases [J].
Doyle, J .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2004, 51 (05) :520-521
[5]   The rigid nasendoscope as a tool for difficult tracheal intubation: A manikin study [J].
Goodwin, N ;
Latto, IP ;
Hodzovic, I ;
Williams, G ;
Hall, JE .
ANAESTHESIA, 2003, 58 (07) :675-679
[6]   Difficult Airway Society guidelines for management of the unanticipated difficult intubation [J].
Henderson, JJ ;
Popat, MT ;
Latto, IP ;
Pearce, AC .
ANAESTHESIA, 2004, 59 (07) :675-694
[7]  
Kaplan MB, 2004, CAN J ANAESTH, V51, P94, DOI 10.1007/BF03018566
[8]   Evaluation of ease of intubation with the GlideScope® or Macintosh laryngoscope by anaesthetists in simulated easy and difficult laryngoscopy [J].
Lim, TJ ;
Lim, Y ;
Liu, EHC .
ANAESTHESIA, 2005, 60 (02) :180-183
[9]   Ease of intubation with the GlideScope or Macintosh laryngoscope by inexperienced operators in simulated difficult airways [J].
Lim, Y ;
Lim, TJ ;
Liu, EHC .
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2004, 51 (06) :641-642
[10]   The Glidescope® system:: a clinical assessment of performance [J].
Rai, MR ;
Dering, A ;
Verghese, C .
ANAESTHESIA, 2005, 60 (01) :60-64