Is Electron Beam Intraoperative Radiotherapy (ELIOT) Safe in Pregnant Women with Early Breast Cancer? In Vivo Dosimetry to Assess Fetal Dose

被引:21
作者
Galimberti, Viviana [1 ]
Ciocca, Mario [2 ]
Leonardi, Maria Cristina [3 ]
Zanagnolo, Vanna [4 ]
Paola, Baratella [1 ]
Manuela, Sargenti [1 ]
Sahium, Rafaela Cecilio [1 ]
Lazzari, Roberta [3 ]
Gentilini, Oreste [1 ]
Peccatori, Fedro [5 ]
Veronesi, Umberto [1 ]
Orecchia, Roberto [3 ,6 ]
机构
[1] European Inst Oncol, Unit Mol Senol, Senol Dept, I-20141 Milan, Italy
[2] European Inst Oncol, Dept Med Phys, I-20141 Milan, Italy
[3] European Inst Oncol, Dept Radiotherapy, I-20141 Milan, Italy
[4] European Inst Oncol, Dept Gynecol, I-20141 Milan, Italy
[5] European Inst Oncol, Unit Allogen Transplantat, I-20141 Milan, Italy
[6] Univ Milan, Milan, Italy
关键词
CONSERVING SURGERY; RADIATION-THERAPY; CHILDHOOD-CANCER; GAMMA-RADIATION; RISK; IRRADIATION; EXPOSURE;
D O I
10.1245/s10434-008-0172-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Electron beam intraoperative radiotherapy (ELIOT) is a new technique permitting breast radiotherapy to be completed in a single session. Since ELIOT is associated with much reduced irradiation to nontarget tissues, we carried out a study on nonpregnant breast cancer patients to estimate doses to the uterus during ELIOT to better evaluate the possible use of ELIOT in pregnant breast cancer patients. We performed in vivo dosimetry with thermoluminescence radiation detectors (TLDs) in 15 premenopausal patients receiving ELIOT to the breast (prescribed dose 21 Gy) using two mobile linear accelerators. The TLDs were positioned subdiaphragmatically on the irradiated side, at the medial pubic position, and within the uterus. A shielding apron (2 mm lead equivalent) was placed over the viscera from the subcostal to the subpubic region. TLDs showed mean doses of 3.7 mGy (range 1-8.5 mGy) at subdiaphragm, 0.9 mGy (range 0.3-2 mGy) pubic, and 1.7 mGy (range 0.6-3.2 mGy) in utero, for beam energies in the range 5-9 MeV. These findings indicate that ELIOT with a mobile linear accelerator and shielding apron would be safe for the fetus, as doses of a few mGy are not associated with measurable increased risk of fetal damage, and the threshold dose for deterministic effects is estimated at 100-200 mGy. We conclude that studies on the use of ELIOT in pregnant women treated with conservative breast surgery are justified.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 45 条
[21]   Evaluation of skin dose and skin toxicity in patients undergoing intraoperative radiotherapy for early breast cancer [J].
See, Mee-Hoong ;
Ung, Ngie Min ;
Wong, Jeannie Hsiu Ding ;
Zaili, Zainor ;
Malik, Rozita Abdul ;
Bustam, Anita Zarina ;
Saad, Marniza ;
Jamaris, Suniza ;
Mosiun, Joanne Aisha ;
Taib, Nur Aishah Mohd .
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08) :139-147
[22]   Physicians' Opinion on Intraoperative Radiotherapy as a Therapeutic De-Escalation Option in Older Women with Early Breast Cancer [J].
Tallet, Agnes ;
Rey, Dominique ;
Casanova, Clemence ;
Lecourtois, Delphine ;
Bergeaud, Marie ;
Bendiane, Marc-Karim ;
Mancini, Julien .
CURRENT ONCOLOGY, 2023, 30 (03) :2812-2824
[23]   Comparison of Local Recurrence Among Early Breast Cancer Patients Treated With Electron Intraoperative Radiotherapy vs Hypofractionated Photon Radiotherapy an Observational study [J].
Guenzi, Marina ;
Bonzano, Elisabetta ;
Corvo, Renzo ;
Merolla, Francesca ;
Pastorino, Alice ;
Cavagnetto, Francesca ;
Garelli, Stefania ;
Cutolo, Carlo Alberto ;
Friedman, Daniele ;
Belgioia, Liliana .
FRONTIERS IN ONCOLOGY, 2018, 8
[24]   Intraoperative electron radiotherapy in early invasive ductal breast cancer: 6-year median follow-up results of a prospective monocentric registry [J].
Philippson, Catherine ;
Larsen, Samuel ;
Simon, Stephane ;
Vandekerkhove, Christophe ;
De Caluwe, Alex ;
Van Gestel, Dirk ;
Chintinne, Marie ;
Veys, Isabelle ;
De Neubourg, Filip ;
Noterman, Daniele ;
Roman, Mirela ;
Nogaret, Jean-Marie ;
Desmet, Antoine .
BREAST CANCER RESEARCH, 2022, 24 (01)
[25]   Estimating the skin dose near to the applicator and acute toxicity in breast cancer patients: An intraoperative electron radiotherapy technique [J].
Mirkazemi, Maryam Sadat ;
Mahdavi, Seyed Rabi ;
Nafissi, Nahid ;
Monfared, Ali Shabestani ;
Ghoreishi, Seyedeh Masoumeh ;
Gorji, Kourosh Ebrahimnejad .
JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) :650-656
[26]   Long term survival and local control outcomes from single dose targeted intraoperative radiotherapy during lumpectomy (TARGIT-IORT) for early breast cancer: TARGIT-A randomised clinical trial [J].
Vaidya, Jayant S. ;
Bulsara, Max ;
Baum, Michael ;
Wenz, Frederik ;
Massarut, Samuele ;
Pigorsch, Steffi ;
Alvarado, Michael ;
Douek, Michael ;
Saunders, Christobel ;
Flyger, Henrik L. ;
Eiermann, Wolfgang ;
Brew-Graves, Chris ;
Williams, Norman R. ;
Potyka, Ingrid ;
Roberts, Nicholas ;
Bernstein, Marcelle ;
Brown, Douglas ;
Sperk, Elena ;
Laws, Siobhan ;
Suetterlin, Marc ;
Corica, Tammy ;
Lundgren, Steinar ;
Holmes, Dennis ;
Vinante, Lorenzo ;
Bozza, Fernando ;
Pazos, Montserrat ;
Blanc-Onfroy, Magali Le ;
Gruber, Guenther ;
Polkowski, Wojciech ;
Dedes, Konstantin J. ;
Niewald, Marcus ;
Blohmer, Jens ;
McCready, David ;
Hoefer, Richard ;
Kelemen, Pond ;
Petralia, Gloria ;
Falzon, Mary ;
Joseph, David J. ;
Tobias, Jeffrey S. .
BMJ-BRITISH MEDICAL JOURNAL, 2020, 370
[27]   Cosmetic outcome in patients with early stage breast cancer after accelerated partial breast irradiation using intraoperative or external beam radiotherapy [J].
Gunster, Jetske L. B. ;
Jacobs, Daphne H. M. ;
Mast, Mirjam E. ;
Kanter, Antoinette Verbeek-de ;
Fisscher, Ursula J. ;
Petoukhova, Anna L. ;
Speijer, Gabrielle ;
Straver, Marieke ;
Merkus, Jos ;
Marijnen, Corrie A. M. ;
Scholten, Astrid N. .
CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2024, 49
[28]   Validation of in vivo dose using EPID combined with fan-beam CT guidance in post-breast-conserving radiotherapy for early-stage breast cancer [J].
Zhu, Wanli ;
Fang, Jia ;
Zhang, Yi ;
Chen, Meiqin ;
Zhang, Hongzhi ;
Ding, Shubo .
BMC CANCER, 2025, 25 (01)
[29]   Dosimetric Comparison of Different Radiotherapy Techniques to Determine the Absorbed Fetal Dose in Pregnant Patients with Left-Sided Breast Cancer [J].
Gul, Osman Vefa ;
Ivan, Gokcen ;
Basaran, Hamit .
ARAB JOURNAL OF NUCLEAR SCIENCES AND APPLICATIONS, 2021, 54 (04) :96-103
[30]   Comparing the Outcome of Boost Dose of Intraoperative Radiotherapy with Electron (IOERT) and Low-kV X-Ray (IOXRT) and External Beam Radiotherapy (EBRT) in Breast Cancer After Neoadjuvant Chemotherapy [J].
Moini, Nazi ;
Nafissi, Nahid ;
Babaee, Ebrahim ;
Mirzaei, Hamidreza ;
Akbari, Mohammad Esmaeil .
INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2019, 12 (08)