Is Electron Beam Intraoperative Radiotherapy (ELIOT) Safe in Pregnant Women with Early Breast Cancer? In Vivo Dosimetry to Assess Fetal Dose

被引:21
作者
Galimberti, Viviana [1 ]
Ciocca, Mario [2 ]
Leonardi, Maria Cristina [3 ]
Zanagnolo, Vanna [4 ]
Paola, Baratella [1 ]
Manuela, Sargenti [1 ]
Sahium, Rafaela Cecilio [1 ]
Lazzari, Roberta [3 ]
Gentilini, Oreste [1 ]
Peccatori, Fedro [5 ]
Veronesi, Umberto [1 ]
Orecchia, Roberto [3 ,6 ]
机构
[1] European Inst Oncol, Unit Mol Senol, Senol Dept, I-20141 Milan, Italy
[2] European Inst Oncol, Dept Med Phys, I-20141 Milan, Italy
[3] European Inst Oncol, Dept Radiotherapy, I-20141 Milan, Italy
[4] European Inst Oncol, Dept Gynecol, I-20141 Milan, Italy
[5] European Inst Oncol, Unit Allogen Transplantat, I-20141 Milan, Italy
[6] Univ Milan, Milan, Italy
关键词
CONSERVING SURGERY; RADIATION-THERAPY; CHILDHOOD-CANCER; GAMMA-RADIATION; RISK; IRRADIATION; EXPOSURE;
D O I
10.1245/s10434-008-0172-z
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Electron beam intraoperative radiotherapy (ELIOT) is a new technique permitting breast radiotherapy to be completed in a single session. Since ELIOT is associated with much reduced irradiation to nontarget tissues, we carried out a study on nonpregnant breast cancer patients to estimate doses to the uterus during ELIOT to better evaluate the possible use of ELIOT in pregnant breast cancer patients. We performed in vivo dosimetry with thermoluminescence radiation detectors (TLDs) in 15 premenopausal patients receiving ELIOT to the breast (prescribed dose 21 Gy) using two mobile linear accelerators. The TLDs were positioned subdiaphragmatically on the irradiated side, at the medial pubic position, and within the uterus. A shielding apron (2 mm lead equivalent) was placed over the viscera from the subcostal to the subpubic region. TLDs showed mean doses of 3.7 mGy (range 1-8.5 mGy) at subdiaphragm, 0.9 mGy (range 0.3-2 mGy) pubic, and 1.7 mGy (range 0.6-3.2 mGy) in utero, for beam energies in the range 5-9 MeV. These findings indicate that ELIOT with a mobile linear accelerator and shielding apron would be safe for the fetus, as doses of a few mGy are not associated with measurable increased risk of fetal damage, and the threshold dose for deterministic effects is estimated at 100-200 mGy. We conclude that studies on the use of ELIOT in pregnant women treated with conservative breast surgery are justified.
引用
收藏
页码:100 / 105
页数:6
相关论文
共 45 条
[11]   Outcomes of Radical and Boost Dose of Intraoperative Radiotherapy with Electron and Low KV X-Ray Based on Islamic Republic Intraoperative Radiotherapy (IRIORT) Consensus and the External Beam Radiotherapy in Pure Ductal Carcinoma in Situ (DCIS) in Breast Cancer Patients [J].
Hashemi, Solmaz ;
Javadi, Seyedmohammadreza ;
Akbari, Mohammad Esmaeil ;
Mirzaei, Hamid Reza ;
Mahdavi, Seied Rabi .
INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2020, 13 (08) :1-6
[12]   Out-of-field dose assessment for pencil beam scanning proton radiotherapy versus photon radiotherapy for breast cancer in pregnant women [J].
Weessies, Menke ;
Bellezzo, Murillo ;
Hupkens, Britt J. P. ;
Verhaegen, Frank ;
Vilches-Freixas, Gloria .
PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2025, 33
[13]   Full-Dose Intraoperative Electron Radiotherapy for Early Breast Cancer: Evidence from a Single Center's Experience [J].
Stefanelli, Antonio ;
Farina, Eleonora ;
Mastella, Edoardo ;
Fabbri, Sara ;
Turra, Alessandro ;
Bonazza, Simona ;
De Troia, Alessandro ;
Radica, Margherita K. ;
Carcoforo, Paolo .
CANCERS, 2023, 15 (12)
[14]   Local Control Following Single-Dose Intraoperative Radiotherapy Prior to Surgical Excision of Early-Stage Breast Cancer [J].
Kimple, Randall J. ;
Klauber-DeMore, Nancy ;
Kuzmiak, Cherie M. ;
Pavic, Dag ;
Lian, Jun ;
Livasy, Chad A. ;
Chiu, WingKeung M. ;
Moore, Dominic T. ;
Sartor, Carolyn I. ;
Ollila, David W. .
ANNALS OF SURGICAL ONCOLOGY, 2011, 18 (04) :939-945
[15]   Breast-Conserving Surgery and Intraoperative Electron Radiotherapy in Early Breast Cancer: Experience at the Rambam Health Care Campus [J].
Hershko, Dan ;
Abdah-Bortnyak, Roxolyana ;
Nevelsky, Alexander ;
Gez, Eliahu ;
Fried, Georgeta ;
Kuten, Abraham .
ISRAEL MEDICAL ASSOCIATION JOURNAL, 2012, 14 (09) :550-554
[16]   Intraoperative radiotherapy versus whole-breast external beam radiotherapy, and other factors associated with the prognosis of early breast cancer treated with breast-conserving surgery and radiotherapy: a retrospective study from SEER database [J].
Sun, Ming-Shuai ;
Liu, Hong-Jin ;
Liu, Yin-Hua ;
Xu, Ling ;
Ye, Jing-Ming .
TRANSLATIONAL CANCER RESEARCH, 2020, 9 (11) :7125-7139
[17]   Outcomes of Breast Cancer (Invasive Lobular and Ductal Carcinoma) Treated with Boost Intraoperative Electron Radiotherapy Versus Conventional External Beam Radiotherapy [J].
Moayeri, Hassan ;
Esmaeil-Akbari, Mohammad ;
Nafissi, Nahid ;
Mahdavi, Seied Rabi ;
Mirzaei, Hamid Reza ;
Salati, Azam ;
Khayamzade, Maryam ;
Shormeij, Zeinab ;
Shakeri, Jafar ;
Nabatzadeh, Mojgan ;
Shahani, Minoo ;
Kiaee, Marzieh ;
Noorian, Sajad Noorian .
INTERNATIONAL JOURNAL OF CANCER MANAGEMENT, 2019, 12 (01)
[18]   Intraoperative radiotherapy (IORT) versus whole-breast external beam radiotherapy (EBRT) in early stage breast cancer: results from SEER database [J].
Lei, Juan ;
Wang, Yi ;
Bi, Zhuofei ;
Xue, Shengneng ;
Ou, Bing ;
Liu, Kan .
JAPANESE JOURNAL OF RADIOLOGY, 2020, 38 (01) :85-92
[19]   Full-dose intraoperative radiotherapy in older patients with early breast cancer: Analysis of eligible criteria and outcomes [J].
Takanen, Silvia ;
Kalli, Maurizio ;
Vukcaj, Suela ;
Andreoli, Stefano ;
Fortunato, Marco ;
Mauri, Emanuela Maria Pia ;
Paludetti, Antonio ;
Candiago, Elisabetta ;
Cattaneo, Laura ;
Gianatti, Andrea ;
Fenaroli, Privato ;
Cazzaniga, Luigi Franco .
JOURNAL OF GERIATRIC ONCOLOGY, 2019, 10 (02) :359-361
[20]   Fetal Dose Estimation for Pregnant Breast Cancer Patients during Radiotherapy Using an In-house Phantom [J].
Shirkhani, Mostafa ;
Heydarheydari, Sahel ;
Farshchian, Negin ;
Eivazi, Mohammad Taghi ;
Haghparast, Abbas .
MIDDLE EAST JOURNAL OF CANCER, 2020, 11 (01) :99-104