The impact of atrium shape on natural smoke ventilation

被引:16
|
作者
Doheim, R. M. [1 ]
Yohanis, Y. G. [1 ]
Nadjai, A. [1 ]
Elkadi, H. [2 ]
机构
[1] Univ Ulster, Fac Art Design & Built Environm, Sch Built Environm, Belfast BT37 0QB, Antrim, North Ireland
[2] Deakin Univ, Sch Architecture & Built Environm, Fac Sci Engn & Built Environm, Melbourne, Vic, Australia
关键词
Atrium; Natural smoke ventilation; Smoke filling; FDS; FIRE; CORRIDOR; HEIGHT; TESTS; TIME; MW;
D O I
10.1016/j.firesaf.2013.11.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The performance efficiency of natural smoke ventilation in atria spaces are influenced greatly by several design decisions such as atrium shape, height, size and openings location. This paper investigates the impact of atrium shape (horizontal profile) on smoke ventilation performance in naturally ventilated atria. Three different configurations (square, rectangular and triangular prism) with the same area, height, and hence, volume were tested. The smoke ventilation performance is being assessed in terms of smoke filling time using a computational fire dynamic simulator (FDS). FDS is used to simulate the natural smoke filling resulting from atrium fire in the three configurations. The smoke layer interface height as a function of time and soot mass fraction and temperature as a function of height have been registered during the simulation. The predicted transport lag time for initial formation of the smoke layer beneath the ceiling (ceiling jet) was compared for the three tests. In order to test sensitivity of the shapes, all other parameters were designed to be similar in the three tests, and the same fire scenario was applied including inlet and outlet area, and fire size and location. The results showed that the rectangular configuration contributes better to smoke ventilation, and that the triangular configuration is the most critical in terms of smoke filling time, followed by the square configuration. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [41] Smoke control using natural ventilation shafts in a tunnel during construction under the effect of geothermal condition
    Liu, Maozhen
    Fei, Xiaoxian
    Luan, Dia
    Tong, Yunhe
    Jiao, Ao
    Ha, Jiayi
    Li, Yuhao
    Fan, Chuangang
    FIRE SAFETY JOURNAL, 2025, 152
  • [42] Experimental investigation of buoyancy-driven natural ventilation in a building with an atrium using particle image velocimetry (PIV) method
    Bagheri, Mitra
    Barfeh, Danyal Ghanbari
    Karami, Maryam
    Delfani, Shahram
    Hafezi, Mohamadreza
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (05) : 536 - 553
  • [43] STUDY OF SMOKE STRATIFICATION IN ATRIUM HALLS USING SCALE MODEL
    Fong, N. K.
    Ko, C. H.
    HT2009: PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER, VOL 3, 2009, : 139 - 144
  • [44] Study on Fire Evacuation and Smoke Spread of Atrium Metro Station
    Tian, Yang
    Li, Jun-Mei
    Li, Yan-Feng
    Wang, Hong-Yi
    Zhang, Jin
    JOINT CONFERENCES OF 2017 INTERNATIONAL CONFERENCE ON MATERIALS SCIENCE AND ENGINEERING APPLICATION (ICMSEA 2017) AND 2017 INTERNATIONAL CONFERENCE ON MECHANICS, CIVIL ENGINEERING AND BUILDING MATERIALS (MCEBM 2017), 2017, 124
  • [45] Experimental study on the effect of segmented smoke exhaust on smoke exhaust of ultra-thin and tall atrium
    Zhang, Hao
    Wang, Jiuzhu
    Du, Cuifeng
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 28 (28)
  • [46] Prediction of natural and hybrid ventilation performance used for fire-induced smoke control in a large single space
    Tong, Yan
    Huo, Dekai
    Zhu, Peigen
    Niu, Xiaofeng
    FIRE SAFETY JOURNAL, 2018, 100 : 20 - 31
  • [47] A numerical study on smoke back-layering length in V-shaped tunnels under natural ventilation
    Xie, En
    Zhao, Wangda
    Xu, Zhisheng
    Zhang, Xiaochun
    Xu, Weiku
    Wang, Tianxiong
    He, Lu
    FIRE AND MATERIALS, 2022, 46 (08) : 1208 - 1221
  • [48] Smoke development in full-scale sloped long and large curved tunnel fires under natural ventilation
    Zhong MaoHua
    Shi CongLing
    He Li
    Shi JieHong
    Liu Chang
    Tian XiangLiang
    APPLIED THERMAL ENGINEERING, 2016, 108 : 857 - 865
  • [49] Effect of width and slope of large cross-section tunnel on ceiling smoke temperature under natural ventilation
    Liu, Su
    Ye, Chenghao
    Zhang, Peihong
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 3061 - 3081
  • [50] Numerical simulation on the maximum temperature and smoke back-layering length in a tilted tunnel under natural ventilation
    Zhang, Xiaolei
    Lin, Yujie
    Shi, Congling
    Zhang, Jianping
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2021, 107