Application of resistive bolometer, to measurement of X-ray radiation from laser Plasmas

被引:0
作者
Ryc, L [1 ]
Machác, P [1 ]
Bartnik, A [1 ]
Juha, L [1 ]
Kaczmarczyk, J [1 ]
Krása, J [1 ]
Mikolajczyk, J [1 ]
Bittner, M [1 ]
Pfeifer, M [1 ]
Ullschmied, J [1 ]
机构
[1] Inst Plasma Phys & Laser Microfus, Hery 23, PL-00908 Warsaw, Poland
来源
PLASMA 2005 | 2006年 / 812卷
关键词
bolometer; laser plasma; x-rays;
D O I
暂无
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
A metal resistor thin-film bolometer was fabricated using the micro lithographic method and then applied to measurement of x-ray emission from gas-puff targets in the experiments at l-kJ PALS laser in Prague. The detection head with the bolometer is equipped with a precise system for its calibration. The bolometer is of 4-mu m Au capturing layer and 100 % efficiency up to 5 keV. The lowest measurable flux is 5 x 10(-9) J/cm(2).
引用
收藏
页码:275 / +
页数:2
相关论文
共 3 条
[1]  
KISHIMOTO T, 1985, 108 MPQ
[2]  
MACHAC P, 5 INT SPIE C PHON DE
[3]   Large-area YBa2Cu3O7-x bolometers on Si substrates [J].
Vale, LR ;
Ono, RH ;
McDonald, DG ;
Phelan, RJ .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1999, 12 (11) :856-858