Identification of specific pre-analytical quality control markers in plasma and serum samples

被引:9
|
作者
Ruiz-Godoy, Luz [1 ]
Enriquez-Carcamo, Virginia [1 ]
Suarez-Roa, Lourdes [1 ]
Lourdes Lopez-Castro, Maria [1 ]
Santamaria, Abel [2 ]
Orozco-Morales, Mario [3 ,4 ]
Laura Colin-Gonzalez, Ana [1 ]
机构
[1] Inst Nacl Cancerol, Banco Tumores, SSA San Fernando 22 Col,Secc 16, Mexico City 14080, DF, Mexico
[2] Inst Nacl Neurol & Neurocirug, Lab Aminoacidos Excitadores, Insurgentes Sur 3877, Mexico City 14269, DF, Mexico
[3] Inst Nacl Cancerol, Unidad Funct Oncol Torac, Mexico City 14080, DF, Mexico
[4] Inst Nacl Cancerol, Lab Med Personalizada, Mexico City 14080, DF, Mexico
关键词
FREEZE-THAW CYCLES; WHOLE-BLOOD; LACTATE-DEHYDROGENASE; STORAGE TEMPERATURES; DELAYED SEPARATION; STABILITY; BIOBANK; TIME; ANALYTES; IMPACT;
D O I
10.1039/c9ay00131j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Blood is a liquid connective tissue with a complex composition that supplies oxygen and nutrients to cells. It is minimally invasive to obtain and can be used in "omics" technologies. Current research regarding blood-based biomarkers has gained considerable attention as a useful tool for diagnostic, therapeutic, and drug development; however, several research groups have reported controversial results despite using the same analytical platform. Such discrepancy can be caused by errors made during the pre-analytical phase. Therefore, quality control of pre-analytical variables is an important factor that could affect the reproducibility and credibility of results. This review discusses the challenge to identify blood quality control markers and describes several molecules that could be potential candidates.
引用
收藏
页码:2259 / 2271
页数:13
相关论文
共 46 条
  • [31] Stability of the Human Plasma Proteome to Pre-analytical Variability as Assessed by an Aptamer-Based Approach
    Daniels, Jaclyn R.
    Cao, Zhijun
    Maisha, Mackean
    Schnackenberg, Laura K.
    Sun, Jinchun
    Pence, Lisa
    Schmitt, Thomas C.
    Kamlage, Beate
    Rogstad, Sarah
    Beger, Richard D.
    Yu, Li-Rong
    JOURNAL OF PROTEOME RESEARCH, 2019, 18 (10) : 3661 - 3670
  • [32] Microparticle content of plasma for transfusion is influenced by the whole blood hold conditions: Pre-analytical considerations for proteomic investigations
    Sparrow, Rosemary L.
    Chan, Kasey Sze-Kei
    JOURNAL OF PROTEOMICS, 2012, 76 : 211 - 219
  • [33] Diurnal variation and short-term pre-analytical stability of serum soluble -klotho in healthy volunteers: a pilot study
    Tan, Sven-Jean
    Smith, Edward R.
    Hewitson, Tim D.
    Holt, Stephen G.
    Toussaint, Nigel D.
    ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (04) : 506 - 509
  • [34] The effect of pre-analytical variables on light transmittance aggregometry in citrated platelet-rich plasma from healthy subjects
    Stegnar, Mojca
    Knezevic, Anja
    Bozic-Mijovski, Mojca
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2010, 48 (10) : 1463 - 1465
  • [35] Can we rely on out-of-hospital blood samples? A prospective interventional study on the pre-analytical stability of blood samples under prehospital emergency medicine conditions
    Prottengeier, Johannes
    Jess, Nicola
    Harig, Frank
    Gall, Christine
    Schmidt, Joachim
    Birkholz, Torsten
    SCANDINAVIAN JOURNAL OF TRAUMA RESUSCITATION & EMERGENCY MEDICINE, 2017, 25
  • [36] Determination of methionine-enkephalin and leucine-enkephalin by LC-MS It in human plasma: Study of pre-analytical stability
    Ozalp, Aliye
    Barroso, Begona
    Meijer, John
    van den Beld, Cas
    ANALYTICAL BIOCHEMISTRY, 2018, 559 : 24 - 29
  • [37] Effects of pre-analytical storage time, temperature, and freeze-thaw times on coagulation factors activities in citrate-anticoagulated plasma
    Zhao, Ying
    Feng, Guofang
    Feng, Limin
    ANNALS OF TRANSLATIONAL MEDICINE, 2018, 6 (23)
  • [38] Pre-analytical stability of haematinics, lactate dehydrogenase and phosphate in whole blood at room temperature up to 24 h, and refrigerated serum stability of lactate dehydrogenase, folate and vitamin B12 up to 72 h using the CRESS checklist
    Williams, Robert
    Jankute, Monika
    Ifrahim, Rizwan
    Cordle, Jane
    Hepburn, Sophie
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, : 734 - 746
  • [39] MS-Based Monitoring of Proteolytic Decay of Synthetic Reporter Peptides for Quality Control of Plasma and Serum Specimens
    Findeisen, Peter
    Thumfart, Joerg Oliver
    Costina, Victor
    Hofheinz, Ralf
    Neumaier, Michael
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2013, 140 (03) : 314 - 323
  • [40] Determination of endocannabinoids and endocannabinoid-like substances in human K3EDTA plasma - LC-MS/MS method validation and pre-analytical characteristics
    Gurke, R.
    Thomas, D.
    Schreiber, Y.
    Schaefer, S. M. G.
    Fleck, S. C.
    Geisslinger, G.
    Ferreiros, N.
    TALANTA, 2019, 204 : 386 - 394