A Novel Adaptive Spectrum Noise Cancellation Approach for Enhancing Heartbeat Rate Monitoring in a Wearable Device

被引:25
作者
Yang, Dong [1 ]
Cheng, Yongqiang [2 ]
Zhu, Jin [1 ]
Xue, Dongfei [2 ]
Abt, Grant [3 ]
Ye, Hangyang [1 ]
Peng, Yonghong [4 ]
机构
[1] Tongji Univ, Dept Control Sci & Engn, Shanghai 201804, Peoples R China
[2] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Hull, Sch Life Sci, Kingston Upon Hull HU6 7RX, N Humberside, England
[4] Univ Sunderland, Fac Comp Sci, Sunderland SR6 0DD, England
关键词
Adaptive spectrum noise cancellation; heartbeat rate measurement; wearable device; PPG; motion artifacts; EMPIRICAL MODE DECOMPOSITION; ARTIFACT REDUCTION; PHOTOPLETHYSMOGRAPHY; ALGORITHM; SIGNALS; BLOOD;
D O I
10.1109/ACCESS.2018.2805223
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a novel approach, adaptive spectrum noise cancellation (ASNC), for motion artifacts removal in photoplethysmography (PPG) signals measured by an optical biosensor to obtain clean PPG waveforms for heartbeat rate calculation. One challenge faced by this optical sensing method is the inevitable noise induced by movement when the user is in motion, especially when the motion frequency is very close to the target heartbeat rate. The proposed ASNC utilizes the onboard accelerometer and gyroscope sensors to detect and remove the artifacts adaptively, thus obtaining accurate heartbeat rate measurement while in motion. The ASNC algorithm makes use of a commonly accepted spectrum analysis approaches in medical digital signal processing, discrete cosine transform, to carry out frequency domain analysis. Results obtained by the proposed ASNC have been compared with the classic algorithms, the adaptive threshold peak detection and adaptive noise cancellation. The mean (standard deviation) absolute error and mean relative error of heartbeat rate calculated by ASNC is 0.33 (0.57) beats.min(-1) and 0.65%, by adaptive threshold peak detection algorithm is 2.29 (2.21) beats.min(-1) and 8.38%, by adaptive noise cancellation algorithm is 1.70 (1.50) beats.min(-1) and 2.02%. While all algorithms performed well with both simulated PPG data and clean PPG data collected from our verity device in situations free of motion artifacts, ASNC provided better accuracy when motion artifacts increase, especially when motion frequency is very close to the heartbeat rate.
引用
收藏
页码:8364 / 8375
页数:12
相关论文
共 41 条
[21]   Motion artifact reduction in photoplethysmography using independent component analysis [J].
Kim, BS ;
Yoo, SK .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2006, 53 (03) :566-568
[22]   The use of phase in complex spectrum subtraction for robust speech recognition [J].
Kleinschmidt, Tristan ;
Sridharan, Sridha ;
Mason, Michael .
COMPUTER SPEECH AND LANGUAGE, 2011, 25 (03) :585-600
[23]   Efficient nonlinear algorithm for envelope detection in white light interferometry [J].
Larkin, KG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1996, 13 (04) :832-843
[24]  
Lee BG, 2015, IEEE ENG MED BIO, P6126, DOI 10.1109/EMBC.2015.7319790
[25]   PHOTOPLETHYSMOGRAPHY .1. COMPARISON WITH LASER DOPPLER FLOWMETRY [J].
LINDBERG, LG ;
TAMURA, T ;
OBERG, PA .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1991, 29 (01) :40-47
[26]  
Mozaffarian D, 2015, CIRCULATION, V131, pE29, DOI 10.1161/CIR.0000000000000152
[27]   Wearable Sensors for Human Activity Monitoring: A Review [J].
Mukhopadhyay, Subhas Chandra .
IEEE SENSORS JOURNAL, 2015, 15 (03) :1321-1330
[28]  
Narayanan K.A., 2011, Inactivation of Salmonella Enteritidis PT 30 on Almonds with a Fluidized Bed Atmospheric Pressure Plasma, P1, DOI [10.1109/EIT.2011.5978571, DOI 10.1109/EIT.2011.5978571]
[29]   Adaptive noise removal from biomedical signals using warped polynomials [J].
Philips, W .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (05) :480-492
[30]  
Santos SA, 2012, ACTA POLYTECH, V52, P80