A Novel Adaptive Spectrum Noise Cancellation Approach for Enhancing Heartbeat Rate Monitoring in a Wearable Device

被引:25
作者
Yang, Dong [1 ]
Cheng, Yongqiang [2 ]
Zhu, Jin [1 ]
Xue, Dongfei [2 ]
Abt, Grant [3 ]
Ye, Hangyang [1 ]
Peng, Yonghong [4 ]
机构
[1] Tongji Univ, Dept Control Sci & Engn, Shanghai 201804, Peoples R China
[2] Univ Hull, Sch Engn & Comp Sci, Kingston Upon Hull HU6 7RX, N Humberside, England
[3] Univ Hull, Sch Life Sci, Kingston Upon Hull HU6 7RX, N Humberside, England
[4] Univ Sunderland, Fac Comp Sci, Sunderland SR6 0DD, England
关键词
Adaptive spectrum noise cancellation; heartbeat rate measurement; wearable device; PPG; motion artifacts; EMPIRICAL MODE DECOMPOSITION; ARTIFACT REDUCTION; PHOTOPLETHYSMOGRAPHY; ALGORITHM; SIGNALS; BLOOD;
D O I
10.1109/ACCESS.2018.2805223
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This paper presents a novel approach, adaptive spectrum noise cancellation (ASNC), for motion artifacts removal in photoplethysmography (PPG) signals measured by an optical biosensor to obtain clean PPG waveforms for heartbeat rate calculation. One challenge faced by this optical sensing method is the inevitable noise induced by movement when the user is in motion, especially when the motion frequency is very close to the target heartbeat rate. The proposed ASNC utilizes the onboard accelerometer and gyroscope sensors to detect and remove the artifacts adaptively, thus obtaining accurate heartbeat rate measurement while in motion. The ASNC algorithm makes use of a commonly accepted spectrum analysis approaches in medical digital signal processing, discrete cosine transform, to carry out frequency domain analysis. Results obtained by the proposed ASNC have been compared with the classic algorithms, the adaptive threshold peak detection and adaptive noise cancellation. The mean (standard deviation) absolute error and mean relative error of heartbeat rate calculated by ASNC is 0.33 (0.57) beats.min(-1) and 0.65%, by adaptive threshold peak detection algorithm is 2.29 (2.21) beats.min(-1) and 8.38%, by adaptive noise cancellation algorithm is 1.70 (1.50) beats.min(-1) and 2.02%. While all algorithms performed well with both simulated PPG data and clean PPG data collected from our verity device in situations free of motion artifacts, ASNC provided better accuracy when motion artifacts increase, especially when motion frequency is very close to the heartbeat rate.
引用
收藏
页码:8364 / 8375
页数:12
相关论文
共 41 条
[1]   DISCRETE COSINE TRANSFORM [J].
AHMED, N ;
NATARAJAN, T ;
RAO, KR .
IEEE TRANSACTIONS ON COMPUTERS, 1974, C 23 (01) :90-93
[2]   Photoplethysmography and its application in clinical physiological measurement [J].
Allen, John .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :R1-R39
[3]  
[Anonymous], 2001, NY TIMES
[4]  
Asada HH, 2004, P ANN INT C IEEE ENG, V26, P2157
[5]   SUPPRESSION OF ACOUSTIC NOISE IN SPEECH USING SPECTRAL SUBTRACTION [J].
BOLL, SF .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1979, 27 (02) :113-120
[6]   THE FOURIER-TRANSFORM [J].
BRACEWELL, RN .
SCIENTIFIC AMERICAN, 1989, 260 (06) :86-&
[7]  
CHEN WH, 1977, IEEE T COMMUN, V25, P1004, DOI 10.1109/TCOM.1977.1093941
[8]  
Cheng YQ, 2014, 2014 IEEE SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE IN BIG DATA (CIBD), P26
[9]   INVIVO REFLECTANCE OF BLOOD AND TISSUE AS A FUNCTION OF LIGHT WAVELENGTH [J].
CUI, W ;
OSTRANDER, LE ;
LEE, BY .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (06) :632-639
[10]  
Dong Yang, 2015, 2015 IET International Conference on Biomedical Image and Signal Processing (ICBISP 2015), DOI 10.1109/ICSENS.2015.7370326