Accuracy of the Omron RX-M, an automated blood pressure measuring device, measuring blood pressure at the wrist, according to a modified British Hypertension Society protocol

被引:9
作者
Braam, RL [1 ]
Aslan, B [1 ]
Thien, T [1 ]
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Internal Med, NL-6500 HB Nijmegen, Netherlands
关键词
blood pressure measurement; oscillometric method; sphygmomanometer; hypertension; arterial blood pressure;
D O I
10.1097/00126097-200402000-00006
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To determine the accuracy of the Omron RX-M, a device measuring blood pressure oscillometrically at the wrist. Methods: In 89 subjects (mean age 55 14 years) blood pressure measurements at the wrist with the Omron RX-M were compared to sequential blood pressure measurements with a mercury sphygmomanometer at the (same) upper-arm and to simultaneous measurements with the Omron HEM-705 CP at the opposite arm. Measurements with analyzed according to the British Hypertension Society (BHS) - protocol 1993, to the protocol of the Association for the Advancement of Medical Instrumentation (AAMI) and (retrospectively) to the new 'International Protocol'. Results: Mean differences (+/-SD) between the measurements with the mercury sphygmomanometer and the Omron RX-M were -7.5 +/- 8.4 mmHg for diastolic blood pressure (DBP) and -2.5 +/- 12.2 mmHg for systolic blood pressure (SBP), thus not fulfilling the AAMI-criteria (less than or equal to 5 +/- 8). According to the BHS-criteria a grade D was achieved for both DBP and SBP. Compared to the Omron HEM 705 CP results were -6.3 +/- 7.1 for DBP (grade D) and -4.1 +/- 12.7 for SBP (grade D). The Omron RX-M also failed to pass the new 'International Protocol' in phase 1. Conclusion: Although easy to use, based on this study the Omron RX-M can not be recommended to determine blood pressure accurately. (C) 2004 Lippincott Williams Wilkins.
引用
收藏
页码:25 / 30
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 1987, AM NAT STAND EL AUT
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Accuracy of the Welch Allyn Vital Signs Monitor 52000 automatic blood pressure measuring device according to a modified British Hypertension Society protocol [J].
Braam, RL ;
de Maat, C ;
Thien, T .
BLOOD PRESSURE MONITORING, 2002, 7 (03) :185-189
[4]   The influence of the method of data analysis on the reported accuracy of automated blood pressure measuring devices [J].
Braam, RL ;
Thien, T .
JOURNAL OF HYPERTENSION, 2001, 19 (10) :1765-1767
[5]  
DEGAUDEMARIS R, 1994, J HYPERTENS, V12, P831
[6]   Inter-arm differences in blood pressure: when are they clinically significant? [J].
Lane, D ;
Beevers, M ;
Barnes, N ;
Bourne, J ;
John, A ;
Malins, S ;
Beevers, DG .
JOURNAL OF HYPERTENSION, 2002, 20 (06) :1089-1095
[7]  
O'Brien, 1996, Blood Press Monit, V1, P55
[8]   Proposals for simplifying the validation protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation [J].
O'Brien, E .
BLOOD PRESSURE MONITORING, 2000, 5 (01) :43-45
[9]   Working Group on Blood Pressure Monitoring of the European Society of Hypertension International Protocol for validation of blood pressure measuring devices in adults [J].
O'Brien, E ;
Pickering, T ;
Asmar, R ;
Myers, M ;
Parati, G ;
Staessen, J ;
Mengden, T ;
Imai, Y ;
Waeber, B ;
Palatini, P ;
Atkins, N ;
Gerin, W .
BLOOD PRESSURE MONITORING, 2002, 7 (01) :3-17
[10]   State of the market for devices for blood pressure measurement [J].
O'Brien, E .
BLOOD PRESSURE MONITORING, 2001, 6 (06) :281-286