Correlation of serum and dried blood spot results for quantitation of Schistosoma circulating anodic antigen: A proof of principle

被引:12
作者
Downs, Jennifer A. [1 ,2 ]
Corstjens, Paul L. A. M. [3 ]
Mngara, Julius [4 ]
Lutonja, Peter [4 ]
Isingo, Raphael [4 ]
Urassa, Mark [4 ]
Kornelis, Dieuwke [5 ]
van Dam, Govert J. [5 ]
机构
[1] Weill Cornell Med Coll, Ctr Global Hlth, New York, NY 10065 USA
[2] Bugando Med Ctr, Dept Med, Mwanza, Tanzania
[3] Leiden Univ, Med Ctr, Dept Mol Cell Biol, NL-2300 RC Leiden, Netherlands
[4] Mwanza Res Ctr, Natl Inst Med Res, Mwanza, Tanzania
[5] Leiden Univ, Med Ctr, Dept Parasitol, Leiden, Netherlands
基金
美国国家卫生研究院;
关键词
Schistosomiasis; Dried blood spot; Circulating anodic antigen; Serum; Diagnostics; LATERAL FLOW ASSAY; FILTER PAPERS; FIBER-WEB; MANSONI; DIAGNOSIS; PRAZIQUANTEL; INFECTIONS; COLLECTION; ANTIBODIES; URINE;
D O I
10.1016/j.actatropica.2015.06.026
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
Circulating anodic antigen (CAA) testing is a powerful, increasingly-used tool for diagnosis of active schistosome infection. We sought to determine the feasibility and reliability of measuring CAA in blood spots collected on Whatman 903 protein saver cards, which are the predominant filter papers used worldwide for dried blood spot (DBS) research and clinical care. CAA was eluted from blood spots collected from 19 individuals onto Whatman 903 cards in Mwanza, Tanzania, and the assay was optimized to achieve CAA ratios comparable to those obtained from the spots' corresponding serum samples. The optimized assay was then used to determine the correlation of serum samples (n= 16) with DBS from cards that had been stored for 8 years at ambient temperature. Using a DBS volume equivalent to approximately four times the quantity of serum, CAA testing in DBS had a sensitivity of 76% and a specificity of 79% compared to CAA testing in serum. CAA testing was reliable in samples eluted from Whatman 903 cards that had been stored for 8 years at ambient temperature. The overall kappa coefficient was 0.53 (standard error 0.17, p <0.001). We conclude that CAA can be reliably and accurately measured in DBS collected onto the filter paper that is most commonly used for clinical care and research, and that can be stored from prolonged periods of time. This finding opens new avenues for future work among more than 700 million individuals living in areas worldwide in which schistosomes are endemic. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:59 / 63
页数:5
相关论文
共 25 条
[1]  
Bergwerff A.A., 1994, J BIOL CHEM, V269, P510
[2]   Dried blood spots as a source of anti-malarial antibodies for epidemiological studies [J].
Corran, Patrick H. ;
Cook, Jackie ;
Lynch, Caroline ;
Leendertse, Heleen ;
Manjurano, Alphaxard ;
Griffin, Jamie ;
Cox, Jonathan ;
Abeku, Tarekegn ;
Bousema, Teun ;
Ghani, Azra C. ;
Drakeley, Chris ;
Riley, Eleanor .
MALARIA JOURNAL, 2008, 7 (1)
[3]   Up-converting phosphor technology-based lateral flow assay for detection of Schistosoma circulating anodic antigen in serum [J].
Corstjens, Paul L. A. M. ;
van Lieshout, Lisette ;
Zuiderwijk, Michel ;
Kornelis, Dieuwke ;
Tanke, Hans J. ;
Deelder, Andre M. ;
van Dam, Govert J. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (01) :171-176
[4]   Tools for diagnosis, monitoring and screening of Schistosoma infections utilizing lateral-flow based assays and upconverting phosphor labels [J].
Corstjens, Paul L. A. M. ;
De Dood, Claudia J. ;
Kornelis, Dieuwke ;
Fat, Elisa M. Tjon Kon ;
Wilson, R. Alan ;
Kariuki, Thomas M. ;
Nyakundi, Ruth K. ;
Loverde, Philip T. ;
Abrams, William R. ;
Tanke, Hans J. ;
Van Lieshout, Lisette ;
Deelder, Andre M. ;
Van Dam, Govert J. .
PARASITOLOGY, 2014, 141 (14) :1841-1855
[5]   CIRCULATING ANODIC ANTIGEN LEVELS IN SERUM BEFORE AND AFTER CHEMOTHERAPY WITH PRAZIQUANTEL IN SCHISTOSOMIASIS MANSONI [J].
DEJONGE, N ;
DECALUWE, P ;
HILBERATH, GW ;
KRIJGER, FW ;
POLDERMAN, AM ;
DEELDER, AM .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1989, 83 (03) :368-372
[6]   ULTRASTRUCTURAL-LOCALIZATION OF THE CIRCULATING ANODIC ANTIGEN IN THE DIGESTIVE-TRACT OF SCHISTOSOMA-MANSONI USING MONOCLONAL-ANTIBODIES IN AN IMMUNOGOLD LABELING PROCEDURE [J].
DEWATER, R ;
FRANSEN, JAM ;
DEELDER, AM .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 1986, 35 (03) :549-558
[7]   Association of Schistosomiasis and HIV Infection in Tanzania [J].
Downs, Jennifer A. ;
van Dam, Govert J. ;
Changalucha, John M. ;
Corstjens, Paul L. A. M. ;
Peck, Robert N. ;
de Dood, Claudia J. ;
Bang, Heejung ;
Andreasen, Aura ;
Kalluvya, Samuel E. ;
van Lieshout, Lisette ;
Johnson, Warren D., Jr. ;
Fitzgerald, Daniel W. .
AMERICAN JOURNAL OF TROPICAL MEDICINE AND HYGIENE, 2012, 87 (05) :868-873
[8]   Polypropylene fibre web, a new matrix for sampling blood for immunodiagnosis of schistosomiasis [J].
Jamaly, S ;
Chihani, T ;
Deelder, AM ;
Gabone, R ;
Nilsson, LA ;
Ouchterlony, O .
TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 1997, 91 (04) :412-415
[9]   Filter paper collection of Plasmodium falciparum mRNA for detecting low-density gametocytes [J].
Jones, Sophie ;
Sutherland, Colin J. ;
Hermsen, Cornelus ;
Arens, Theo ;
Teelen, Karina ;
Hallett, Rachel ;
Corran, Patrick ;
van der Vegte-Bolmer, Marga ;
Sauerwein, Robert ;
Drakeley, Chris J. ;
Bousema, Teun .
MALARIA JOURNAL, 2012, 11
[10]   CIRCULATING ANODIC AND CATHODIC ANTIGEN IN SERUM AND URINE FROM SCHISTOSOMA-HAEMATOBIUM - INFECTED CAMEROONIAN CHILDREN RECEIVING PRAZIQUANTEL - A LONGITUDINAL-STUDY [J].
KREMSNER, PG ;
ENYONG, P ;
KRIJGER, FW ;
DEJONGE, N ;
ZOTTER, GM ;
THALHAMMER, F ;
MUHLSCHLEGEL, F ;
BIENZLE, U ;
FELDMEIER, H ;
DEELDER, AM .
CLINICAL INFECTIOUS DISEASES, 1994, 18 (03) :408-413