Depth profiling cross-linked poly(methyl methacrylate) films: a time-of-flight secondary ion mass spectrometry approach

被引:7
|
作者
Naderi-Gohar, Soheila [1 ,2 ,5 ]
Huang, Kevin M. H. [1 ,6 ]
Wu, Yiliang [3 ,7 ]
Lau, Woon Ming [4 ]
Nie, Heng-Yong [1 ,2 ]
机构
[1] Univ Western Ontario, Surface Sci Western, 999 Collip Circle, London, ON N6G 0J3, Canada
[2] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
[3] Xerox Res Ctr Canada Ltd, Adv Mat Lab, Mississauga, ON L5K 2L1, Canada
[4] Chengdu Green Energy & Green Mfg Technol R&D Ctr, Chengdu 610207, Sichuan, Peoples R China
[5] Adv Mineral Technol Lab, 100 Collip Circle, London, ON N6G 4X8, Canada
[6] Amec Foster Wheeler, 700 Univ Ave, Toronto, ON M5G 1X6, Canada
[7] TE Connect, 306 Constitut Dr, Menlo Pk, CA 94025 USA
基金
加拿大自然科学与工程研究理事会;
关键词
COATED POLYMER-FILMS; TOF-SIMS; ORGANIC ELECTRONICS; LINKING; SURFACES; BUCKMINSTERFULLERENE; TRANSISTORS; C-60(+); BEAMS; MODEL;
D O I
10.1002/rcm.7801
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: In order to determine the degree of cross-linking on the surface and its variations in a nanometer-scale depth of organic materials, we developed an approach based on time-of-flight secondary ion mass spectrometry (TOF-SIMS), which provides rich chemical information in the form of fragment ions. TOF-SIMS is extremely surface-sensitive and capable of depth profiling with the use of a sputter ion beam to remove controllable amounts of substance. METHODS: Poly(methyl methacrylate) (PMMA) films spin-coated on a Si substrate were cross-linked using a recently developed, surface sensitive, hyperthermal hydrogen projectile bombardment technique. The ion intensity ratio between two ubiquitous hydrocarbon ions, C6H- and C4H-, detected in TOF-SIMS, denoted as., was used to assess the degree of cross-linking of the PMMA films. The cross-linking depth of the PMMA films was revealed by depth profiling. into the polymer films using a C-60(+) sputter beam. RESULTS: The control PMMA film spin-coated on a Si substrate was characterized by rho = 32% on its surface when using a 25 keV Bi-3(+) primary ion beam. This parameter on the PMMA films subjected to HHIC treatment for 10, 100 and 500 s increased to 45%, 56% and 65%, respectively. The depth profiles of rho obtained using a 10 keV C-60(+) ion beam resembled an exponential decay, from which the cross-linking depth was estimated to be 3, 15 and 39 nm, respectively, for the three cross-linked PMMA films. CONCLUSIONS: We demonstrated that the ion intensity ratio of C6H- to C4H- detected in TOF-SIMS provides a unique and simple means to assess the degree of cross-linking of the surface of PMMA films cross-linked by the surface sensitive hyperthermal hydrogen projectile bombardment technique. With a C-60(+) sputter beam, we were able to depth profile the PMMA films and determine cross-linking depths of the cross-linked polymer films at nanometer resolutions. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [31] Analysis of liposome model systems by time-of-flight secondary ion mass spectrometry
    Lovric, Jelena
    Keighron, Jacqueline D.
    Angerer, Tina B.
    Li, Xianchan
    Malmberg, Per
    Fletcher, John S.
    Ewing, Andrew G.
    SURFACE AND INTERFACE ANALYSIS, 2014, 46 : 74 - 78
  • [32] Time-of-flight secondary ion mass spectrometry analysis of chitosan-treated viscose fibres
    Finsgar, Matjaz
    Ristic, Tijana
    Fardim, Pedro
    Zemljic, Lidija Fras
    ANALYTICAL BIOCHEMISTRY, 2018, 557 : 131 - 141
  • [33] Surface studies of heterogeneous catalysts by time-of-flight secondary ion mass spectrometry
    Grams, Jacek
    EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2010, 16 (03) : 453 - 461
  • [34] Photodegradation of poly(ether sulphone) Part 1. A time-of-flight secondary ion mass spectrometry study
    Norrman, K
    Kingshott, P
    Kaeselev, B
    Ghanbari-Siahkali, A
    SURFACE AND INTERFACE ANALYSIS, 2004, 36 (12) : 1533 - 1541
  • [35] A study of chemical structure in "barkinite" using time-of-flight secondary ion mass spectrometry
    Sun, XG
    INTERNATIONAL JOURNAL OF COAL GEOLOGY, 2001, 47 (01) : 1 - 8
  • [36] Sample Preparation of Biological Tissues and Cells for the Time-of-Flight Secondary Ion Mass Spectrometry
    Gulin, A. A.
    Nadtochenko, V. A.
    Pogorelova, V. N.
    Melnikov, M. Ya
    Pogorelov, A. G.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (06) : 701 - 710
  • [37] The surface chemistry of starch granules studied by time-of-flight secondary ion mass spectrometry
    Baldwin, PM
    Melia, CD
    Davies, MC
    JOURNAL OF CEREAL SCIENCE, 1997, 26 (03) : 329 - 346
  • [38] Sensitive and multiplexed analysis of aflatoxins using time-of-flight secondary ion mass spectrometry
    Ahn, Jang-Hyuk
    Jeong, Young-Su
    Lee, Tae Geol
    Kim, Young-Pil
    Kim, Hak-Sung
    BIOCHIP JOURNAL, 2012, 6 (01) : 34 - 40
  • [39] Detecting changes in arabidopsis cell wall composition using time-of-flight secondary ion mass spectrometry
    Tsai, Alex Yi-Lin
    Goacher, Robyn E.
    Master, Emma R.
    SURFACE AND INTERFACE ANALYSIS, 2015, 47 (05) : 626 - 631
  • [40] Towards practical time-of-flight secondary ion mass spectrometry lignocellulolytic enzyme assays
    Goacher, Robyn E.
    Tsai, Alex Yi-Lin
    Master, Emma R.
    BIOTECHNOLOGY FOR BIOFUELS, 2013, 6