Depth profiling cross-linked poly(methyl methacrylate) films: a time-of-flight secondary ion mass spectrometry approach

被引:7
|
作者
Naderi-Gohar, Soheila [1 ,2 ,5 ]
Huang, Kevin M. H. [1 ,6 ]
Wu, Yiliang [3 ,7 ]
Lau, Woon Ming [4 ]
Nie, Heng-Yong [1 ,2 ]
机构
[1] Univ Western Ontario, Surface Sci Western, 999 Collip Circle, London, ON N6G 0J3, Canada
[2] Univ Western Ontario, Dept Phys & Astron, London, ON N6A 3K7, Canada
[3] Xerox Res Ctr Canada Ltd, Adv Mat Lab, Mississauga, ON L5K 2L1, Canada
[4] Chengdu Green Energy & Green Mfg Technol R&D Ctr, Chengdu 610207, Sichuan, Peoples R China
[5] Adv Mineral Technol Lab, 100 Collip Circle, London, ON N6G 4X8, Canada
[6] Amec Foster Wheeler, 700 Univ Ave, Toronto, ON M5G 1X6, Canada
[7] TE Connect, 306 Constitut Dr, Menlo Pk, CA 94025 USA
基金
加拿大自然科学与工程研究理事会;
关键词
COATED POLYMER-FILMS; TOF-SIMS; ORGANIC ELECTRONICS; LINKING; SURFACES; BUCKMINSTERFULLERENE; TRANSISTORS; C-60(+); BEAMS; MODEL;
D O I
10.1002/rcm.7801
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
RATIONALE: In order to determine the degree of cross-linking on the surface and its variations in a nanometer-scale depth of organic materials, we developed an approach based on time-of-flight secondary ion mass spectrometry (TOF-SIMS), which provides rich chemical information in the form of fragment ions. TOF-SIMS is extremely surface-sensitive and capable of depth profiling with the use of a sputter ion beam to remove controllable amounts of substance. METHODS: Poly(methyl methacrylate) (PMMA) films spin-coated on a Si substrate were cross-linked using a recently developed, surface sensitive, hyperthermal hydrogen projectile bombardment technique. The ion intensity ratio between two ubiquitous hydrocarbon ions, C6H- and C4H-, detected in TOF-SIMS, denoted as., was used to assess the degree of cross-linking of the PMMA films. The cross-linking depth of the PMMA films was revealed by depth profiling. into the polymer films using a C-60(+) sputter beam. RESULTS: The control PMMA film spin-coated on a Si substrate was characterized by rho = 32% on its surface when using a 25 keV Bi-3(+) primary ion beam. This parameter on the PMMA films subjected to HHIC treatment for 10, 100 and 500 s increased to 45%, 56% and 65%, respectively. The depth profiles of rho obtained using a 10 keV C-60(+) ion beam resembled an exponential decay, from which the cross-linking depth was estimated to be 3, 15 and 39 nm, respectively, for the three cross-linked PMMA films. CONCLUSIONS: We demonstrated that the ion intensity ratio of C6H- to C4H- detected in TOF-SIMS provides a unique and simple means to assess the degree of cross-linking of the surface of PMMA films cross-linked by the surface sensitive hyperthermal hydrogen projectile bombardment technique. With a C-60(+) sputter beam, we were able to depth profile the PMMA films and determine cross-linking depths of the cross-linked polymer films at nanometer resolutions. Copyright (C) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:381 / 388
页数:8
相关论文
共 50 条
  • [1] Characterization and ion-induced degradation of cross-linked poly(methyl methacrylate) studied using time of flight secondary ion mass spectrometry
    Wagner, M. S.
    Lenghaus, K.
    Gillen, G.
    Tarlov, M. J.
    APPLIED SURFACE SCIENCE, 2006, 253 (05) : 2603 - 2610
  • [2] Transition temperature of poly(methyl methacrylate) determined by time-of-flight secondary ion mass spectrometry and contact angle measurements
    Fu, Yi
    Lau, Yiu-Ting R.
    Weng, Lu-Tao
    Ng, Kai-Mo
    Chan, Chi-Ming
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 504 : 758 - 764
  • [3] Quantitative depth profiling of Si1-xGex structures by time-of-flight secondary ion mass spectrometry and secondary neutral mass spectrometry
    Drozdov, M. N.
    Drozdov, Y. N.
    Csik, A.
    Novikov, A. V.
    Vad, K.
    Yunin, P. A.
    Yurasov, D. V.
    Belykh, S. F.
    Gololobov, G. P.
    Suvorov, D. V.
    Tolstogouzov, A.
    THIN SOLID FILMS, 2016, 607 : 25 - 31
  • [4] Impact energy dependence of SF5+ ion beam damage of poly(methyl methacrylate) studied by time-of-flight secondary ion mass spectrometry
    Wagner, MS
    Gillen, G
    APPLIED SURFACE SCIENCE, 2004, 231 : 169 - 173
  • [5] Are cluster ion analysis beams good choices for hydrogen depth profiling using time-of-flight secondary ion mass spectrometry?
    Zhu, Zihua
    Shutthanandan, Vaithiyalingam
    SURFACE AND INTERFACE ANALYSIS, 2012, 44 (01) : 89 - 93
  • [6] Time-of-Flight Secondary Ion Mass Spectrometry Profiling for Arsenic in Silicon Dioxide Matrix
    Teo, Han Wei
    Wang, Yun
    Mo, Zhi Qiang
    Zhao, Si Ping
    Proceedings of the 2016 IEEE 23rd International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA), 2016, : 109 - 111
  • [7] Pore confined time-of-flight secondary ion electrochemical mass spectrometry
    Wang, Jun-Gang
    Yu, Ru-Jia
    Hua, Xin
    Long, Yi-Tao
    CHEMICAL SOCIETY REVIEWS, 2023, 52 (08) : 2596 - 2616
  • [8] Time-of-flight secondary ion mass spectrometry analyses of vancomycin
    Du, Lin
    Yang, Xiaohui
    Li, Wenqiang
    Li, Haoying
    Feng, Shanbao
    Zeng, Rong
    Yu, Bin
    Xiao, Liangxing
    Liu, Yu
    Tu, Mei
    Nie, Heng-Yong
    BIOINTERPHASES, 2018, 13 (03)
  • [9] Secondary ion mass spectrometry and time-of-flight secondary ion mass spectrometry study of impurity measurements in HgCdTe
    Price, Steve
    Wang, Larry
    Wang, Alice
    Ginwalla, Arwa
    Mowat, Ian
    JOURNAL OF ELECTRONIC MATERIALS, 2007, 36 (08) : 1106 - 1109
  • [10] Secondary Ion Mass Spectrometry and Time-of-Flight Secondary Ion Mass Spectrometry Study of Impurity Measurements in HgCdTe
    Steve Price
    Larry Wang
    Alice Wang
    Arwa Ginwalla
    Ian Mowat
    Journal of Electronic Materials, 2007, 36 : 1106 - 1109