Nonlinear damping based semi-active building isolation system

被引:21
作者
Ho, Carmen [1 ]
Zhu, Yunpeng [1 ]
Lang, Zi-Qiang [1 ]
Billings, Stephen A. [1 ]
Kohiyama, Masayuki [2 ]
Wakayama, Shizuka [2 ]
机构
[1] Univ Sheffield, Dept Automat Control & Syst Engn, Sheffield S1 3JD, S Yorkshire, England
[2] Keio Univ, Dept Syst Design Engn, Hiyoshi, Japan
基金
欧洲研究理事会; 英国工程与自然科学研究理事会;
关键词
Isolation system; Earthquake; Nonlinear damping; Acceleration transmissibilities; Experimental studies; FREQUENCY-RESPONSE FUNCTION; VIBRATION CONTROL; DESIGN; STIFFNESS; DRIFT;
D O I
10.1016/j.jsv.2018.03.023
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Many buildings in Japan currently have a base-isolation system with a low stiffness that is designed to shift the natural frequency of the building below the frequencies of the ground motion due to earthquakes. However, the ground motion observed during the 2011 Tohoku earthquake contained strong long-period waves that lasted for a record length of 3 min. To provide a novel and better solution against the long-period waves while maintaining the performance of the standard isolation range, the exploitation of the characteristics of nonlinear damping is proposed in this paper. This is motivated by previous studies of the authors, which have demonstrated that nonlinear damping can achieve desired performance over both low and high frequency regions and the optimal nonlinear damping force can be realized by closed loop controlled semi-active dampers. Simulation results have shown strong vibration isolation performance on a building model with identified parameters and have indicated that nonlinear damping can achieve low acceleration trans-missibilities round the structural natural frequency as well as the higher ground motion frequencies that have been frequently observed during most earthquakes in Japan. In addition, physical building model based laboratory experiments are also conducted, The results demonstrate the advantages of the proposed nonlinear damping technologies over both traditional linear damping and more advanced Linear-Quadratic Gaussian (LQG) feedback control which have been used in practice to address building isolation system design and implementation problems. In comparison with the tuned-mass damper and other active control methods, the proposed solution offers a more pragmatic, low-cost, robust and effective alternative that can be readily installed into the base-isolation system of most buildings. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:302 / 317
页数:16
相关论文
共 28 条
  • [1] Semi-active control of isolated and damaged structures using online damage detection
    Amini, Fereidoun
    Mohajeri, Seyed Ahmad
    Javanbakht, Majd
    [J]. SMART MATERIALS AND STRUCTURES, 2015, 24 (10)
  • [2] Billings SA, 2013, NONLINEAR SYSTEM IDENTIFICATION: NARMAX METHODS IN THE TIME, FREQUENCY, AND SPATIO-TEMPORAL DOMAINS, P1, DOI 10.1002/9781118535561
  • [3] Switching Gains for Semiactive Damping via Nonconvex Lyapunov Functions
    Blanchini, Franco
    Colaneri, Patrizio
    Casagrande, Daniele
    Gardonio, Paolo
    Miani, Stefano
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2014, 22 (02) : 721 - 728
  • [4] Coupled building control using acceleration feedback
    Christenson, RE
    Spencer, BF
    Hori, N
    Seto, K
    [J]. COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2003, 18 (01) : 4 - 18
  • [5] Dan M., 2014, SYSTEM IDENTIFICATIO, P3841
  • [6] Dan M., 2016, EACS 2016
  • [7] Seismic performance evaluation of an MR elastomer-based smart base isolation system using real-time hybrid simulation
    Eem, S. H.
    Jung, H. J.
    Koo, J. H.
    [J]. SMART MATERIALS AND STRUCTURES, 2013, 22 (05)
  • [8] Sliding mode fault detection and fault-tolerant control of smart dampers in semi-active control of building structures
    Fallah, Arash Yeganeh
    Taghikhany, Touraj
    [J]. SMART MATERIALS AND STRUCTURES, 2015, 24 (12)
  • [9] Fujita K., 2016, FRONT BUILT ENV, V2, P1
  • [10] Guo P. F., 2012, DAMPING SYSTEM DESIG