Design and evaluation of an external filter technique for exposure equalization in mammography

被引:8
|
作者
Keshavmurthy, SP [1 ]
Goodsitt, MM [1 ]
Chan, HP [1 ]
Helvie, MA [1 ]
Christodoulou, E [1 ]
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
关键词
mammography; equalization; external filtration; simulation;
D O I
10.1118/1.598659
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We are developing an external filter method for equalizing x-ray exposure in the peripheral region of:the breast. This method requires the use of only a limited number of custom-built filters for different breast shapes in a given view. This paper describes,the design methodology for these external filters. The filter effectiveness was evaluated through a simulation study on 171 mediolateral and 196 craniocaudal view digitized mammograms:and :through imaging of a breast phantom. The degree of match between the simulated filter and:the: individual 3-D exposure profiles at the breast periphery was quantified. An analysis was performed;to investigate the effect of filter misalignment. The simulation study indicates that the filter is effective in equalizing exposures for more than 80% of the breast images in our database. The tolerance in filter misalignment was estimated to be about +/-2 mm for the CC view and ii mm for, the MLO view at the image plane. Some misalignment artifacts were demonstrated with simulated filtered mammograms. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)01108-6].
引用
收藏
页码:1655 / 1669
页数:15
相关论文
共 50 条
  • [1] Evaluation of an anatomical filter-based exposure equalization technique in mammography
    Panayiotakis, G
    Skiadopoulos, S
    Solomou, E
    Pierrakeas, C
    Costaridou, L
    Kalogeropoulou, CP
    Dimopoulos, J
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (850): : 1049 - 1057
  • [2] EXPOSURE EQUALIZATION TECHNIQUE IN MAMMOGRAPHY
    LAM, KL
    CHAN, HP
    INVESTIGATIVE RADIOLOGY, 1989, 24 (02) : 154 - 157
  • [3] AN ANATOMICAL FILTER FOR EXPOSURE EQUALIZATION IN MAMMOGRAPHY
    PANAYIOTAKIS, G
    LIKAKI, H
    KOLITSI, Z
    DIMOPOULOS, J
    EUROPEAN JOURNAL OF RADIOLOGY, 1992, 15 (01) : 15 - 17
  • [4] A phantom-based evaluation of an exposure equalization technique in mammography
    Skiadopoulos, S
    Pierrakeas, C
    Costaridou, L
    Kalogeropoulou, CP
    Panayiotakis, G
    BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (862): : 977 - 985
  • [5] Wavelet-based quantitative evaluation of a digital density equalization technique in mammography
    Stefanoyiannis, A. P.
    Gerogiannis, I.
    Efstathopoulos, E.
    Christofides, S.
    Kaplanis, P. A.
    Gouliamos, A.
    11TH MEDITERRANEAN CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING AND COMPUTING 2007, VOLS 1 AND 2, 2007, 16 (1-2): : 899 - +
  • [6] SCANNING EQUALIZATION MAMMOGRAPHY - PRELIMINARY EVALUATION
    OESTMANN, JW
    STOEL, B
    SCHRIJVERHOF, M
    VROOMAN, H
    SCHULTZEKOOL, L
    RADIOGRAPHICS, 1994, 14 (01) : 123 - 128
  • [7] EFFICIENT FILTER DESIGN FOR LOUDSPEAKER EQUALIZATION
    GREENFIELD, R
    HAWKSFORD, MO
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1991, 39 (10): : 739 - 751
  • [8] A digital density equalization technique to improve visualization of breast periphery in mammography
    Stefanoyiannis, AP
    Costaridou, L
    Sakellaropoulos, P
    Panayiotakis, G
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (868): : 410 - 420
  • [9] Development of Integration HTSC Linear Phase Filter With External Equalization
    Zhang, Tianliang
    Yang, Kai
    Luo, Zhengxiang
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2013, 23 (04)
  • [10] EFFICIENT FILTER DESIGN FOR LOUDSPEAKER EQUALIZATION - REPLY
    GREENFIELD, R
    HAWKSFORD, MO
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1993, 41 (05): : 365 - 366