Morphometric Analysis of Lister's Tubercle and Its Consequences on Volar Plate Fixation of Distal Radius Fractures

被引:35
作者
Clement, Hans
Pichler, Wolfgang [1 ]
Nelson, David
Hausleirner, Lisa
Tesch, Norbert Peter
Grechenig, Wolfgang
机构
[1] Med Univ Graz, Dept Traumatol, A-8036 Graz, Austria
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2008年 / 33A卷 / 10期
关键词
Extensor pollicis ruptures; Lister's tubercle; radius fracture; volar plating;
D O I
10.1016/j.jhsa.2008.08.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose The objective of this study was to measure the size and shape of Lister's tubercle and the depth of the extensor pollicis longus (EPL) groove to assess the risk of injury to the EPL tendon when performing volar plating of distal radius fractures. Methods The length and height of Lister's tubercle and the depth of the EPL groove were 47, measured in 100 cadavers. Results The size of Lister's tubercle varied from 2 to 6 mm (average, 3.6 mm) in height radial 41, to the tubercle and from 6 to 26 mm (average, 18.3 mm) in length. The depth of the EPL groove varied from I to 5 mm (average, 2.8 mm), with 63% being greater than 2 mm in depth. The height between the depth of the groove and the tip of the tubercle varied between 4 and 10 mm (average, 7.1 mm). No correlation was found with gender or right-side or left-side specimens. Conclusions The individual and combined height of Lister's tubercle and the depth of the EPL groove are considerable. This fact needs to be considered when performing volar plating of distal radius fractures because of the possibility that it might be difficult to determine precisely the presence and amount of past-pointing of the distal screws. (J Hand Surg 2008; 33A: 1716-1719. Copyright (c) 2008 by the American Society for Surgery (of the Hand. All rights reserved.)
引用
收藏
页码:1716 / 1719
页数:4
相关论文
共 18 条
[1]   Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures [J].
Al-Rashid, M. ;
Theivendran, K. ;
Craigen, M. A. C. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (12) :1610-1612
[2]   Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate [J].
Arora, Rohit ;
Lutz, Martin ;
Hennerbichler, Alfred ;
Krappinger, Dietinar ;
Espen, David ;
Gabl, Markus .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2007, 21 (05) :316-322
[3]   Two potential causes of EPL rupture after distal radius volar plate fixation [J].
Benson, Eric C. ;
DeCarvalho, Alex ;
Mikola, Elizabeth A. ;
Veitch, John M. ;
Moneim, Moheb S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (451) :218-222
[4]   Volar fixed-angle plating of distal radius extension fractures: influence of plate position on secondary loss of reduction - A biomechanic study in a cadaveric model [J].
Drobetz, H ;
Bryant, AL ;
Pokorny, T ;
Spitaler, R ;
Leixnering, M ;
Jupiter, JB .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (04) :615-622
[5]   EXTENSOR POLLICIS LONGUS RUPTURE AT THE TIP OF A PROMINENT FIXATION SCREW - REPORT OF 3 CASES [J].
FAILLA, JM ;
KONIUCH, MP ;
MOED, BR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1993, 18A (04) :648-651
[6]  
Heidemann J, 2002, Handchir Mikrochir Plast Chir, V34, P324, DOI 10.1055/s-2002-36303
[7]   RUPTURE OF THE EXTENSOR POLLICIS LONGUS TENDON IN UNDISPLACED COLLES TYPE OF FRACTURE [J].
HELAL, B ;
CHEN, SC ;
IWEGBU, G .
HAND, 1982, 14 (01) :41-47
[8]  
HOLLINSHEAD WH, 1964, ANATOMY SURG, V3, P392
[9]   DELAYED RUPTURE OF THE THUMB EXTENSOR TENDON - A 5-YEAR STUDY OF 18 CONSECUTIVE CASES [J].
HOVE, LM .
ACTA ORTHOPAEDICA SCANDINAVICA, 1994, 65 (02) :199-203
[10]   LATE RUPTURE OF THE EXTENSOR POLLICIS LONGUS TENDON - THE CASE AGAINST ATTRITION [J].
JENKINS, NH ;
MACKIE, IG .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1988, 13B (04) :448-449