Measured Visual Field Extent Varies With Peripheral Stimulus Flicker Rate in Very Young Children

被引:4
作者
Delaney, Suzanne M. [1 ]
Dobson, Velma [1 ,2 ]
Mohan, Kathleen M. [2 ]
机构
[1] Univ Arizona, Dept Psychol, Tucson, AZ 85711 USA
[2] Univ Arizona, Dept Ophthalmol & Vis Sci, Tucson, AZ 85711 USA
基金
美国国家卫生研究院;
关键词
perimetry; binocular visual fields; flicker; children; infants;
D O I
10.1097/01.opx.0000178059.39998.bd
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this article is to describe measured visual field extent in very young children in response to variation in peripheral stimulus flicker rate. Methods. Binocular visual field extent was measured using a black, double-arc perimeter and an LED static perimetry procedure in 120 11-month-old, 120 17-month-old, and 120 30-month-old children and 40 adults. Each subject was tested with one of four flicker rates: 1 Hz, 10 Hz, 20 Hz, or 40 Hz. An interpolated estimate of the eccentricity at which 50% of subjects detected the peripheral stimulus and the mean of the farthest eccentricity at which subjects detected the peripheral stimulus were calculated for each flicker rate for each age group. Results. In 11-, 17-, and 30-month-old children, but not in adults, measured visual field extent (eccentricity at which the stimulus was detected) varied significantly with rate of stimulus flicker. The largest measured visual field extent was produced by a 10-Hz stimulus and the smallest was produced by 1-Hz and 40-Hz stimuli. Measured visual field extent in children was similar to that of adults for 10-Hz flicker, but smaller than that of adults for 1-Hz, 20-Hz, and 40-Hz flicker. Conclusions. These results underscore the importance of standardizing stimulus parameters when developing tests for clinical assessment of visual fields in children. Furthermore, for longitudinal assessment of young patients, use of a 10-Hz flicker rate, in combination with the other parameters used in the present study, would help to avoid difficulties in interpretation that could arise from an interaction between age-related and disease-related changes that might occur if other stimulus flicker rates were used.
引用
收藏
页码:800 / 806
页数:7
相关论文
共 14 条
[1]   SACCADIC LOCALIZATION OF VISUAL TARGETS BY VERY YOUNG HUMAN INFANT [J].
ASLIN, RN ;
SALAPATEK, P .
PERCEPTION & PSYCHOPHYSICS, 1975, 17 (03) :293-302
[2]  
CASSON EJ, 1993, INVEST OPHTH VIS SCI, V34, P3096
[3]  
Delaney SM, 2004, OPTOMETRY VISION SCI, V81, P922
[4]   The effect of flicker rate on measured visual field extent in very young children [J].
Delaney, SM ;
Dobson, V ;
Mohan, KM ;
Harvey, EM .
OPTOMETRY AND VISION SCIENCE, 2001, 78 (11) :846-852
[5]   Visual field extent in children 3.5-30 months of age tested with a double-arc LED perimeter [J].
Dobson, V ;
Brown, AM ;
Harvey, EM ;
Narter, DB .
VISION RESEARCH, 1998, 38 (18) :2743-2760
[6]  
FAUBERT J, 1991, PERIMETRY UPDATE 1990/1991, P381
[7]   GROWTH OF EFFECTIVE VISUAL-FIELD FROM BIRTH TO 7 WEEKS [J].
HARRIS, P ;
MACFARLANE, A .
JOURNAL OF EXPERIMENTAL CHILD PSYCHOLOGY, 1974, 18 (02) :340-348
[8]   The influence of a central stimulus on visual field measurements in children from 3.5 to 30 months of age [J].
Harvey, EM ;
Dobson, V ;
Narter, DB .
OPTOMETRY AND VISION SCIENCE, 1997, 74 (09) :768-774
[9]  
Lewis T. L., 1997, Investigative Ophthalmology and Visual Science, V38, pS64
[10]  
Lewis TL, 1996, INVEST OPHTH VIS SCI, V37, pS1067