Detection of Glaucoma Progression by Assessment of Segmented Macular Thickness Data Obtained Using Spectral Domain Optical Coherence Tomography

被引:76
|
作者
Na, Jung Hwa [1 ,4 ]
Sung, Kyung Rim [1 ]
Baek, Seunghee [2 ]
Kim, Yoon Jeon [1 ]
Durbin, Mary K. [3 ]
Lee, Hye Jin [1 ]
Kim, Hwang Ki [4 ]
Sohn, Yong Ho [4 ]
机构
[1] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Ophthalmol, Seoul 138736, South Korea
[2] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Clin Epidemiol & Biostat, Seoul 138736, South Korea
[3] Carl Zeiss Meditec Inc, Dublin, CA USA
[4] Konyang Univ, Kims Eye Hosp, Dept Ophthalmol, Myung Gok Eye Res Inst, Seoul, South Korea
关键词
NERVE-FIBER LAYER; GANGLION-CELL LOSS; VISUAL-FIELD PROGRESSION; POLE RETINAL THICKNESS; OPEN-ANGLE GLAUCOMA; POSTERIOR POLE; HUMAN EYES; CIRRUS HD; DISC; ELECTRORETINOGRAM;
D O I
10.1167/iovs.11-9369
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. We evaluated the clinical use of segmented macular layer thickness measurement in terms of glaucoma diagnosis and the ability to detect progression, and to compare such outcomes to those by circumpapillary retinal nerve fiber layer (cRNFLT) and total macular thickness (TMT) measurements. METHODS. The study included 141 glaucomatous and 61 healthy eyes. All glaucomatous eyes were subjected to at least four spectral domain optical coherence tomography (SD-OCT) examinations (mean follow-up, 2.13 years). Segmented macular layers were the macular nerve fiber layer (NFL), ganglion cell and inner plexiform layer (GCA), and outer retinal layer (ORL; from outer plexiform layer to retinal pigment epithelium). Areas under receiver operating characteristic curves (AUCs) discriminating healthy from glaucomatous eyes were determined in baseline measurements. The sensitivity and specificity of these parameters in terms of glaucoma progression detection were determined, with reference to assessment of optic disc/retinal nerve fiber layer (RNFL) photographs/visual field (VF) deterioration as standard(s). RESULTS. GCA afforded the best diagnostic performance among three macular layers. The AUC of the GCA thickness (GCAT) was less than that of cRNFLT (0.869 vs. 0.953, P = 0.018), but superior to that of TMT (0.790, P = 0.05). Of the eyes, 38 showed progression during follow-up by standard methods. The sensitivities of TMT, GCAT, and cRNFLT values in terms of detection of progression were 14%, 8%, and 5%, respectively. CONCLUSIONS. Although baseline cRNFL measurement was optimal in terms of glaucoma diagnosis, the GCAT and TMT showed similar levels of sensitivity in progression detection. (Invest Ophthalmol Vis Sci. 2012;53:3817-3826) DOI:10.1167/iovs.11-9369
引用
收藏
页码:3817 / 3826
页数:10
相关论文
共 50 条
  • [21] Assessment of the effect of age on macular layer thickness in a healthy Chinese cohort using spectral-domain optical coherence tomography
    Xu, Qian
    Li, Ying
    Cheng, Ying
    Qu, Yi
    BMC OPHTHALMOLOGY, 2018, 18
  • [22] Optical coherence tomography angiography compared with optical coherence tomography for detection of glaucoma progression with high myopia
    Chang, Pei-Yao
    Wang, Jiun-Yi
    Wang, Jia-Kang
    SCIENTIFIC REPORTS, 2025, 15 (01):
  • [23] Three-Dimensional Spectral-Domain Optical Coherence Tomography Data Analysis for Glaucoma Detection
    Xu, Juan
    Ishikawa, Hiroshi
    Wollstein, Gadi
    Bilonick, Richard A.
    Folio, Lindsey S.
    Nadler, Zach
    Kagemann, Larry
    Schuman, Joel S.
    PLOS ONE, 2013, 8 (02):
  • [24] Diagnostic Capability of Spectral-Domain Optical Coherence Tomography for Glaucoma
    Wu, Huijuan
    De Boer, Johannes F.
    Chen, Teresa C.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) : 815 - 826
  • [25] Optical Coherence Tomography Angiography Compared With Optical Coherence Tomography Macular Measurements for Detection of Glaucoma
    Wan, Kelvin H.
    Lam, Alexander K. N.
    Leung, Christopher Kai-Shun
    JAMA OPHTHALMOLOGY, 2018, 136 (08) : 866 - 874
  • [26] Reference Standard Test and the Diagnostic Ability of Spectral Domain Optical Coherence Tomography in Glaucoma
    Rao, Harsha L.
    Yadav, Ravi K.
    Addepalli, Uday K.
    Begum, Viquar U.
    Senthil, Sirisha
    Choudhari, Nikhil S.
    Garudadri, Chandra S.
    JOURNAL OF GLAUCOMA, 2015, 24 (06) : E151 - E156
  • [27] Macular thickness in healthy Saudi adults A spectral-domain optical coherence tomography study
    Al-Zamil, Waseem M.
    Al-Zwaidi, Fahad M.
    Yassin, Sanaa A.
    SAUDI MEDICAL JOURNAL, 2017, 38 (01) : 63 - 69
  • [28] Diagnosing Preperimetric Glaucoma with Spectral Domain Optical Coherence Tomography
    Lisboa, Renato
    Leite, Mauro T.
    Zangwill, Linda M.
    Tafreshi, Ali
    Weinreb, Robert N.
    Medeiros, Felipe A.
    OPHTHALMOLOGY, 2012, 119 (11) : 2261 - 2269
  • [29] Detection of Primary Angle Closure Glaucoma Progression by Optical Coherence Tomography
    Kurysheva, Natalia I.
    Lepeshkina, Lyudmila V.
    JOURNAL OF GLAUCOMA, 2021, 30 (05) : 410 - 420
  • [30] Macular thickness measured by spectral-domain optical coherence tomography in healthy Thai eyes
    Choovuthayakorn, Janejit
    Watanachai, Nawat
    Chaikitmongkol, Voraporn
    Patikulsila, Direk
    Kunavisarut, Paradee
    Ittipunkul, Nimitr
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (06) : 569 - 576