Colorimetric determination of lead(II) or mercury(II) based on target induced switching of the enzyme-like activity of metallothionein-stabilized copper nanoclusters

被引:46
作者
Liu, Ran [1 ]
Zuo, Li [1 ]
Huang, Xiaorong [1 ]
Liu, Shimeng [1 ]
Yang, Guiying [1 ]
Li, Shiya [1 ]
Lv, Changyin [1 ]
机构
[1] Univ South China, Coll Publ Hlth, Hengyang 421001, Peoples R China
基金
中国国家自然科学基金;
关键词
Nanozymes; Catalase-like activity; Peroxidase-like activity; Pb-Cu; Hg-Cu alloy; Heavy metal; Environmental samples; PEROXIDASE-LIKE ACTIVITY; GOLD NANOCLUSTERS; SENSITIVE DETECTION; MIMICKING ACTIVITY; IONS; NANOPARTICLES; FLUORESCENCE; MIMETICS; H2O2;
D O I
10.1007/s00604-019-3360-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is shown that metallothionein-stabilized copper nanoclusters (MT-CuNCs) display catalase-like activity. In the presence of either lead(II) or mercury(II), the catalase-like activity is converted to a peroxidase-like activity. On addition of Pb(II) or Hg(II), the inhibitory effect of MT-CuNCs on the chromogenic reaction of 3,3,5,5-tetramethylbenzidine (TMB) with H2O2 is weakened. On the other hand, the catalytic effect of the nanoclusters on the chromogenic reaction is increased. The system MT-CuNCs-Pb(II)/Hg(II) exhibits high affinity for the substrates TMB and H2O2. Their catalytic behavior follows Michaelis-Menten kinetics. Based on these findings, a method was developed for visual detection (via the blue coloration formed) and spectrophotometric determination (at 450nm) of Pb(II) and Hg(II). The linear range for Pb(II) extends from 0.7 to96M, and the linear ranges for Hg(II) from 97nMto2.3M and from3.1Mto15.6M. The detection limits are 142nM for Pb(II) and 43.8nM for Hg(II).
引用
收藏
页数:8
相关论文
共 34 条
  • [31] Enhanced peroxidase activity and tumour tissue visualization by cobalt-doped magnetoferritin nanoparticles
    Zhang, Tongwei
    Cao, Changqian
    Tang, Xu
    Cai, Yao
    Yang, Caiyun
    Pan, Yongxin
    [J]. NANOTECHNOLOGY, 2017, 28 (04)
  • [32] DNA-Capped Mesoporous Silica Nanoparticles as an Ion-Responsive Release System to Determine the Presence of Mercury in Aqueous Solutions
    Zhang, Yunfei
    Yuan, Quan
    Chen, Tao
    Zhang, Xiaobing
    Chen, Yan
    Tan, Weihong
    [J]. ANALYTICAL CHEMISTRY, 2012, 84 (04) : 1956 - 1962
  • [33] Colorimetric determination of Hg(II) based on a visually detectable signal amplification induced by a Cu@Au-Hg trimetallic amalgam with peroxidase-like activity
    Zhao, Yan
    Qiang, Hong
    Chen, Zhengbo
    [J]. MICROCHIMICA ACTA, 2017, 184 (01) : 107 - 115
  • [34] Detection of Hg2+ based on the selective inhibition of peroxidase mimetic activity of BSA-Au clusters
    Zhu, Rui
    Zhou, Yan
    Wang, Xi-Liang
    Liang, Li-Ping
    Long, Yi-Juan
    Wang, Qin-Long
    Zhang, Hai-Jie
    Huang, Xiao-Xiao
    Zheng, Hu-Zhi
    [J]. TALANTA, 2013, 117 : 127 - 132