Improved velocity-selective labeling pulses for myocardial ASL

被引:24
作者
Landes, Vanessa [1 ]
Javed, Ahsan [2 ]
Jao, Terrence [3 ]
Qin, Qin [4 ,5 ]
Nayak, Krishna [1 ,2 ]
机构
[1] Univ Southern Calif, Viterbi Sch Engn, Dept Biomed Engn, 3740 McClintock Ave,EEB 400, Los Angeles, CA 90089 USA
[2] Univ Southern Calif, Viterbi Sch Engn, Ming Hsieh Dept Elect & Comp Engn, Los Angeles, CA 90089 USA
[3] Univ Southern Calif, Keck Sch Med, Los Angeles, CA 90089 USA
[4] Johns Hopkins Univ, Russell H Morgan Dept Radiol & Radiol Sci, Div MR Res, Sch Med, Baltimore, MD USA
[5] Kennedy Krieger Inst, FM Kirby Res Ctr Funct Imaging, Baltimore, MD USA
基金
美国国家卫生研究院;
关键词
arterial spin labeling; myocardial perfusion; RF pulse design; velocity selective ASL; velocity-selective labeling; FLOW VELOCITY; BLOOD-FLOW; MR-ANGIOGRAPHY; DESIGN;
D O I
10.1002/mrm.28253
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To develop and evaluate an improved velocity-selective (VS) labeling pulse for myocardial arterial spin labeling (ASL) perfusion imaging that addresses two limitations of current pulses: (1) spurious labeling of moving myocardium and (2) low labeling efficiency. Methods The proposed myocardial VSASL labeling pulse is designed using a Fourier Transform based Velocity-Selective labeling pulse train. The pulse utilizes bipolar velocity-encoding gradients, a 9-tap velocity-encoding envelope, and double-refocusing pulses with Malcolm Levitt phase cycling. Amplitudes of the velocity-encoding envelope were optimized to minimize the labeling of myocardial velocities during stable diastole (+/- 2-3 cm/s) and maximize the labeling of coronary velocities (10-130 cm/s during rest/stress or 10-70 cm/s during rest). Myocardial ASL experiments were performed in seven healthy subjects using the previously developed VS-ASL protocol by Jao et al with the two proposed VS pulses and original VS pulse. Myocardial ASL experiments were also performed using FAIR ASL. Myocardial perfusion and physiological noise (PN) were evaluated and compared. Results Bloch simulations of the first and second proposed pulses show <2% labeling over +/- 3 cm/s and +/- 2 cm/s, respectively. Bloch simulations also show the mean labeling efficiency of arterial blood is 1.23 over the relevant coronary arterial ranges. In-vivo VSASL experiments show the proposed pulses provided comparable measurements to FAIR ASL and reduced TSNR in 5 of 7 subjects compared to the original VS pulse. Conclusion We demonstrate an improved VS labeling pulse specifically for myocardial ASL perfusion imaging to reduce spurious labeling of moving myocardium and PN.
引用
收藏
页码:1909 / 1918
页数:10
相关论文
共 30 条
[1]   Coronary artery flow velocity is related to lumen area and regional left ventricular mass [J].
Anderson, HV ;
Stokes, MJ ;
Leon, M ;
Abu-Halawa, SA ;
Stuart, Y ;
Kirkeeide, RL .
CIRCULATION, 2000, 102 (01) :48-54
[2]   Myocardial Perfusion Assessment in Humans Using Steady-Pulsed Arterial Spin Labeling [J].
Capron, Thibaut ;
Troalen, Thomas ;
Robert, Benjamin ;
Jacquier, Alexis ;
Bernard, Monique ;
Kober, Frank .
MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (04) :990-998
[3]  
Cerqueira MD., 2003, Child. A Glob. J. Child Res, P1448, DOI DOI 10.1161/01.CIR.0000060923.07573.F2
[4]   Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans [J].
Chareonthaitawee, P ;
Kaufmann, PA ;
Rimoldi, O ;
Camici, PG .
CARDIOVASCULAR RESEARCH, 2001, 50 (01) :151-161
[5]   Velocity-selective RF pulses in MRI [J].
de Rochefort, L ;
Maître, X ;
Bittoun, J ;
Durand, E .
MAGNETIC RESONANCE IN MEDICINE, 2006, 55 (01) :171-176
[6]   3D Noncontrast MR Angiography of the Distal Lower Extremities Using Flow-Sensitive Dephasing (FSD)-Prepared Balanced SSFP [J].
Fan, Zhaoyang ;
Sheehan, John ;
Bi, Xiaoming ;
Liu, Xin ;
Carr, James ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (06) :1523-1532
[7]   Color-coded measures of myocardial velocity throughout the cardiac cycle by tissue Doppler imaging to quantify regional left ventricular function [J].
Gorcsan, J ;
Gulati, VK ;
Mandarino, WA ;
Katz, WE .
AMERICAN HEART JOURNAL, 1996, 131 (06) :1203-1213
[8]   An Optimized Design to Reduce Eddy Current Sensitivity in Velocity-Selective Arterial Spin Labeling Using Symmetric BIR-8 Pulses [J].
Guo, Jia ;
Meakin, James A. ;
Jezzard, Peter ;
Wong, Eric C. .
MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (03) :1085-1094
[9]  
Hargreaves B, BLOCH SIMULATION EQU
[10]   Demonstration of velocity selective myocardial arterial spin labeling perfusion imaging in humans [J].
Jao, Terrence R. ;
Nayak, Krishna S. .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (01) :272-278