A Comparison Between Separated Electrodes and Concentric Electrodes for Electrotactile Stimulation

被引:6
作者
Stephens-Fripp, Benjamin [1 ,2 ,3 ]
Mutlu, Rahim [1 ,2 ]
Alici, Gursel [1 ,2 ]
机构
[1] Univ Wollongong, Appl Mechatron & Biomed Res Grp, Sch Mech Mat Mechatron & Biomed Engn, Wollongong, NSW 2522, Australia
[2] Univ Wollongong, ARC Ctr Excellence Electromat Sci, Wollongong, NSW 2522, Australia
[3] Facebook Real Labs Res, Redmond, WA 98052 USA
来源
IEEE TRANSACTIONS ON MEDICAL ROBOTICS AND BIONICS | 2021年 / 3卷 / 01期
关键词
Electrotactile feedback; prosthetics; sensory feedback; electrode comparison; electrical stimulation; SENSORY FEEDBACK; RUBBER HAND; PROSTHESIS; AMPUTEES; VIBROTACTILE;
D O I
10.1109/TMRB.2020.3045502
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Equipping prosthetic devices with sensory feedback capability is a continuing research challenge to increase their control and embodiment, and to decrease their rejection by their users. Electrotactile stimulation is one of the non-invasive sensory feedback techniques with a low power, light-weight and relatively easy to control stimulation mechanism to provide the feedback. Currently, there are two electrode setups used in the literature, concentric electrodes and separated electrodes, to apply the electrotactile stimulation to deliver tactile feedback. There is minimal data available in the literature to compare the two electrode setups. This study compares the impact of the electrode arrangements on the dynamic range, just noticeable difference (JND), comfort level, degree of localisation, intensity and type of sensation induced, and the resulting EMG interference from the electrotactile stimulation. The experimental results presented suggest that the concentric electrodes induce a more comfortable and realistic sensation with a reduction in the probability of inducing undesired feeling of pain, pinch or pinprick sensations. Further, the concentric electrodes result in an increased localisation of the induced sensation whilst maintaining a similar dynamic range and JND. EMG interference was shown to be lower for the concentric electrodes.
引用
收藏
页码:241 / 252
页数:12
相关论文
共 69 条
[11]  
Chai GH, 2013, I IEEE EMBS C NEUR E, P271, DOI 10.1109/NER.2013.6695924
[12]   Characterization of evoked tactile sensation in forearm amputees with transcutaneous electrical nerve stimulation [J].
Chai, Guohong ;
Sui, Xiaohong ;
Li, Si ;
He, Longwen ;
Lan, Ning .
JOURNAL OF NEURAL ENGINEERING, 2015, 12 (06)
[13]  
Chatterjee A., 2008, JPO Journal of Prosthetics and Orthotics, V20, P27, DOI DOI 10.1097/01.JP0.0000311041.61628.BE
[14]  
Choi K, 2016, 2016 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2016), P1133, DOI 10.1109/IROS.2016.7759191
[15]   Literature Review on Needs of Upper Limb Prosthesis Users [J].
Cordella, Francesca ;
Ciancio, Anna Lisa ;
Sacchetti, Rinaldo ;
Davalli, Angelo ;
Cutti, Andrea Giovanni ;
Guglielmelli, Eugenio ;
Zollo, Loredana .
FRONTIERS IN NEUROSCIENCE, 2016, 10
[16]   STAIRCASE-METHOD IN PSYCHOPHYSICS [J].
CORNSWEET, TN .
AMERICAN JOURNAL OF PSYCHOLOGY, 1962, 75 (03) :485-&
[17]   Vibrotactile Stimulation Promotes Embodiment of an Alien Hand in Amputees With Phantom Sensations [J].
D'Alonzo, Marco ;
Clemente, Francesco ;
Cipriani, Christian .
IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2015, 23 (03) :450-457
[18]  
Davidson Judith, 2002, J Hand Ther, V15, P62, DOI 10.1053/hanthe.2002.v15.01562
[19]   Restoring motor control and sensory feedback in people with upper extremity amputations using arrays of 96 microelectrodes implanted in the median and ulnar nerves [J].
Davis, T. S. ;
Wark, H. A. C. ;
Hutchinson, D. T. ;
Warren, D. J. ;
O'Neill, K. ;
Scheinblum, T. ;
Clark, G. A. ;
Normann, R. A. ;
Greger, B. .
JOURNAL OF NEURAL ENGINEERING, 2016, 13 (03)
[20]   Time-division multiplexing for myoelectric closed-loop control using electrotactile feedback [J].
Dosen, Strahinja ;
Schaeffer, Marie-Caroline ;
Farina, Dario .
JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2014, 11