Experimental investigation of a regenerated air cycle heat pump heating system with a turbocharger

被引:9
作者
Li, Shuangshuang [1 ]
Wang, Shugang [1 ]
Jiang, Shuang [2 ]
Ma, Zhenjun [3 ]
Zhang, Chunlu [4 ]
机构
[1] Dalian Univ Technol, Fac Infrastruct Engn, Dalian 116024, Peoples R China
[2] Dalian Minzu Univ, Coll Civil Engn, Dalian 116000, Peoples R China
[3] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW 2522, Australia
[4] Tongji Univ, Sch Mech Engn, Shanghai 201804, Peoples R China
来源
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID | 2019年 / 100卷
关键词
Air cycle heat pump; Turbocharger; Test bench; Heating performance; REFRIGERATION SYSTEM; LOAD DENSITY; OPTIMIZATION;
D O I
10.1016/j.ijrefrig.2018.12.029
中图分类号
O414.1 [热力学];
学科分类号
摘要
An air cycle heat pump test bench with a turbocharger and two blowers was designed and presented in this paper. The heating performance of this air cycle heat pump was then experimentally investigated under different operating parameters. The results showed that the pressure ratios of the compressor and turbine could be maintained within the reasonable ranges under the test conditions covered, which means that the two blowers were more suitable for this air cycle heat pump with a turbocharger than one blower. The heating capacity of this heat pump increased as the ambient temperature decreased, while the heating COP was less affected by the hot water supply temperature and the ambient temperature. This indicated that the regenerated air cycle heat pump with the turbocharger could offer more stable operation in applications with a large ambient temperature difference. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:48 / 54
页数:7
相关论文
共 22 条
[1]  
ASHRAE, 2000, COG SYST ENG TURB DR
[2]   Heating load, heating load density and COP optimisations for an endoreversible variable temperature heat reservoir air heat pump [J].
Bi, Y. H. ;
Chen, L. G. ;
Sun, F. R. .
JOURNAL OF THE ENERGY INSTITUTE, 2009, 82 (01) :43-47
[3]   Heating load density optimization of an irreversible simple Brayton cycle heat pump coupled to counter-flow heat exchangers [J].
Bi, Yuehong ;
Xie, Guozhen ;
Chen, Lingen ;
Sun, Fengrui .
APPLIED MATHEMATICAL MODELLING, 2012, 36 (05) :1854-1863
[4]   Exergetic efficiency optimization for an irreversible heat pump working on reversed Brayton cycle [J].
Bi, Yuehong ;
Chen, Lingen ;
Sun, Fengrui .
PRAMANA-JOURNAL OF PHYSICS, 2010, 74 (03) :351-363
[5]  
Bi YH, 2009, REV MEX FIS, V55, P112
[6]  
Catalano L.A., 2010, C THERM ENV ISS EN S, P16
[7]  
De Bellis F, 2011, PROCEEDINGS OF THE ASME TURBO EXPO 2011, VOL 1, P777
[8]  
Dieckmann J., 1979, RES DEV AIR CYCLE HE, P1
[9]  
Edwards T.C., 1972, ROVACS NEW ROTARY VA
[10]  
Edwards T.C., 1975, ROVAC AUTOMOTIVE AIR