Determination of carbamazepine and carbamazepine 10, 11-epoxide in human plasma by tandem liquid chromatography-mass spectrometry with electrospray ionisation

被引:45
作者
van Rooyen, GF [1 ]
Badenhorst, D [1 ]
Swart, KJ [1 ]
Hundt, HKL [1 ]
Scanes, T [1 ]
Hundt, AF [1 ]
机构
[1] FARMOVS, PAREXEL, Clin Res Org, ZA-9324 Brandhof, South Africa
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2002年 / 769卷 / 01期
关键词
carbamazepine; carbamazepine 10,11-epoxide;
D O I
10.1016/S1570-0232(01)00590-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive method for the determination of carbamazepine and carbamazepine 10, 11-epoxide in plasma is described, using high-performance liquid chromatographic separation with tandem mass spectrometry. Samples were purified using liquid-liquid extraction and separated on a Phenomenex(R) Luna C-18 5 mum, 150 x 2 mm column with a mobile phase consisting of acetonitrile, methanol and formic acid (0.1%) (10:70:20, v/v). Detection was performed by a Micromass Quattro Ultima(TM) mass spectrometer in the MRM mode (LC-MS-MS) using electro spray ionisation (ESI+), monitoring the transition of the protonated molecular ion for carbamazepine at m/z 237.05 and carbamazepine 10,11-epoxide at m/z 253.09 to the predominant ions of m/z 194.09 and 180.04, respectively. The mean recovery was 95% for carbamazepine and 101% for carbamazepine 10,11-epoxide, with a lower limit of quantification of 0.722 ng/ml for carbamazepine and 5.15 ng/ml for carbamazepine 10, 11-epoxide, when using 0.5 ml plasma. This high-throughput method was used to quantify 230 samples per day, and is sufficiently sensitive to be employed in pharmacokinetic studies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 7
页数:7
相关论文
共 7 条
[1]   SIMULTANEOUS HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF CARBAMAZEPINE AND ITS PRINCIPAL METABOLITES IN HUMAN-PLASMA AND URINE [J].
CHELBERG, RD ;
GUNAWAN, S ;
TREIMAN, DM .
THERAPEUTIC DRUG MONITORING, 1988, 10 (02) :188-193
[2]   SIMULTANEOUS HPLC DETERMINATION OF OXCARBAZEPINE, CARBAMAZEPINE AND THEIR METABOLITES IN SERUM [J].
KUMPS, A .
JOURNAL OF LIQUID CHROMATOGRAPHY, 1984, 7 (06) :1235-1241
[3]   SIMULTANEOUS DETERMINATION OF CARBAMAZEPINE, PHENYTOIN, PHENOBARBITAL, PRIMIDONE AND THEIR PRINCIPAL METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PHOTODIODE-ARRAY DETECTION [J].
LIU, H ;
DELGADO, M ;
FORMAN, LJ ;
EGGERS, CM ;
MONTOYA, JL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 616 (01) :105-115
[4]   VALIDATION OF THE ANALYSIS OF CARBAMAZEPINE AND ITS 10,11-EPOXIDE METABOLITE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FROM PLASMA - COMPARISON WITH GAS-CHROMATOGRAPHY AND THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE [J].
MARTENS, J ;
BANDITT, P .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (01) :169-173
[5]   Matrix effect in quantitative LC/MS/MS analyses of biological fluids: A method for determination of finasteride in human plasma at picogram per milliliter concentrations [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 1998, 70 (05) :882-889
[6]   SIMULTANEOUS DETERMINATION OF FELBAMATE, PRIMIDONE, PHENOBARBITAL, CARBAMAZEPINE, 2 CARBAMAZEPINE METABOLITES, PHENYTOIN, AND ONE PHENYTOIN METABOLITE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
ROMANYSHYN, LA ;
WICHMANN, JK ;
KUCHARCZYK, N ;
SHUMAKER, RC ;
WARD, D ;
SOFIA, RD .
THERAPEUTIC DRUG MONITORING, 1994, 16 (01) :90-99
[7]  
YUKIMITSU K, 1993, J CHROMATOGR, V622, P47