Detrimental kinematics of a flat on flat total condylar knee arthroplasty

被引:89
作者
Stiehl, JB
Komistek, RD
Dennis, DA
机构
[1] St Lukes Med Ctr, Midw Orthopaed Biomech Lab, Milwaukee, WI USA
[2] Rose Med Ctr, Rose Musculoskeletal Res Lab, Denver, CO 80220 USA
关键词
D O I
10.1097/00003086-199908000-00019
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Fourteen subjects having a flat on flat condylar posterior cruciate retaining total knee arthroplasty were evaluated under different in vivo weightbearing conditions, with six performing a deep knee bend and eight walking at normal gait. An interactive model fitting algorithm was used to convert two-dimensional fluoroscopic images into three-dimensional computer aided design solid model images. The femorotibial contact positions for the medial and lateral condyle started posterior at full extension. With a deep knee bend the lateral condyle acted as a pivot, and the medial condyle slid in the anterior direction. Five of six had lateral condyle liftoff (maximum 1.6 mm) and abnormal positive screw home motion was seen from 0 degrees to 90 degrees flexion, During gait, all femorotibial contact positions were posterior in extension and throughout the cycle. Six of eight patients experienced lateral condyle liftoff (maximum 3.5 mm), but minimal screw home motion was seen. Abnormal medial condyle posteroanterior sliding, lateral condyle liftoff, and erratic screw home motion may be related to abnormal wear characteristics of this flat on flat condylar design.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 37 条
  • [1] Andriacchi T P, 1986, J Arthroplasty, V1, P211, DOI 10.1016/S0883-5403(86)80033-X
  • [2] ANDRIACCHI TP, 1988, J ARTHROPLASTY S, V3, P13
  • [3] THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT
    BARTEL, DL
    BICKNELL, VL
    WRIGHT, TM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) : 1041 - 1051
  • [4] Wear in retrieved condylar knee arthroplasties - A comparison of wear in different designs of 280 retrieved condylar knee prostheses
    Blunn, GW
    Joshi, AB
    Minns, RJ
    Lidgren, L
    Lilley, P
    Ryd, L
    Engelbrecht, E
    Walker, PS
    [J]. JOURNAL OF ARTHROPLASTY, 1997, 12 (03) : 281 - 290
  • [5] BLUNN GW, 1991, CLIN ORTHOP RELAT R, P253
  • [6] BROWN T D, 1984, Journal of Orthopaedic Research, V2, P190, DOI 10.1002/jor.1100020210
  • [7] COLLIER JP, 1990, CLIN ORTHOP RELAT R, V261, P107
  • [8] DENNIS DA, 1996, CLIN ORTHOP RELAT R, V331, P107
  • [9] DENNIS DA, 1997, P 43 ANN ORTH RES SO
  • [10] ELNAHASS E, 1990, P 36 ORTH RES SOC AN