Quantifying the Effect of 3T Magnetic Resonance Imaging Residual System Distortions and Patient-Induced Susceptibility Distortions on Radiation Therapy Treatment Planning for Prostate Cancer

被引:30
作者
Adjeiwaah, Mary [1 ]
Bylund, Mikael [1 ]
Lundman, Josef A. [1 ]
Karlsson, Camilla Thellenberg [1 ]
Jonsson, Joakim H. [1 ]
Nyholm, Tufve [1 ,2 ]
机构
[1] Umea Univ, Dept Radiat Sci, SE-90187 Umea, Sweden
[2] Uppsala Univ, Dept Immunol Genet & Pathol, Med Radiat Phys, Uppsala, Sweden
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2018年 / 100卷 / 02期
关键词
DIGITALLY RECONSTRUCTED RADIOGRAPHS; GEOMETRIC DISTORTION; MRI-SIMULATION; RADIOTHERAPY; IMAGES; IMRT;
D O I
10.1016/j.ijrobp.2017.10.021
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the effect of magnetic resonance system-and patient-induced susceptibility distortions from a 3T scanner on dose distributions for prostate cancers. Methods and Materials: Combined displacement fields from the residual system and patient-induced susceptibility distortions were used to distort 17 prostate patient CT images. VMAT dose plans were initially optimized on distorted CT images and the plan parameters transferred to the original patient CT images to calculate a new dose distribution. Results: Maximum residual mean distortions of 3.19 mm at a radial distance of 25 cm and maximum mean patient-induced susceptibility shifts of 5.8 mm were found using the lowest bandwidth of 122 Hz per pixel. There was a dose difference of <0.5% between distorted and undistorted treatment plans. The 90% confidence intervals of the mean difference between the dCT and CT treatment plans were all within an equivalence interval of (-0.5, 0.5) for all investigated plan quality measures. Conclusions: Patient-induced susceptibility distortions at high field strengths in closed bore magnetic resonance scanners are larger than residual system distortions after using vendor-supplied 3-dimensional correction for the delineated regions studied. However, errors in dose due to disturbed patient outline and shifts caused by patient-induced susceptibility effects are below 0.5%. (C) 2017 The Authors. Published by Elsevier Inc.
引用
收藏
页码:317 / 324
页数:8
相关论文
共 31 条
[1]   ANALYSIS OF MACHINE-DEPENDENT AND OBJECT-INDUCED GEOMETRIC DISTORTION IN 2DFT MR IMAGING [J].
BAKKER, CJG ;
MOERLAND, MA ;
BHAGWANDIEN, R ;
BEERSMA, R .
MAGNETIC RESONANCE IMAGING, 1992, 10 (04) :597-608
[2]   A TECHNIQUE FOR ACCURATE MAGNETIC-RESONANCE-IMAGING IN THE PRESENCE OF FIELD INHOMOGENEITIES [J].
CHANG, H ;
FITZPATRICK, JM .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (03) :319-329
[3]   Dosimetric evaluation of MRI-based treatment planning for prostate cancer [J].
Chen, L ;
Price, RA ;
Nguyen, TB ;
Wang, L ;
Li, JS ;
Qin, L ;
Ding, M ;
Palacio, E ;
Ma, CM ;
Pollack, A .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (22) :5157-5170
[4]   Magnetic resonance-based treatment planning for prostate intensity-modulated radiotherapy:: Creation of digitally reconstructed radiographs [J].
Chen, Lili ;
Nguyen, Thai-Binh ;
Jones, Elan ;
Chen, Zuoqun ;
Luo, Wei ;
Wang, Lu ;
Price, Robert A., Jr. ;
Pollack, Alan ;
Ma, C.-M. Charlie .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :903-911
[5]   MRI-based treatment planning for radiotherapy: Dosimetric verification for prostate IMRT [J].
Chen, LL ;
Price, RA ;
Wang, L ;
Li, JS ;
Qin, LH ;
McNeeley, S ;
Ma, CMC ;
Freedman, GM ;
Pollack, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 60 (02) :636-647
[6]   An evaluation of the use of magnetic field maps to undistort echo-planar images [J].
Cusack, R ;
Brett, M ;
Osswald, K .
NEUROIMAGE, 2003, 18 (01) :127-142
[7]   The contribution of magnetic resonance imaging to the three-dimensional treatment planning of localized prostate cancer [J].
Debois, M ;
Oyen, R ;
Maes, F ;
Verswijvel, G ;
Gatti, G ;
Bosmans, H ;
Feron, M ;
Bellon, E ;
Kutcher, G ;
Van Poppel, H ;
Vanuytsel, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04) :857-865
[8]   Assessment of dosimetric impact of system specific geometric distortion in an MRI only based radiotherapy workflow for prostate [J].
Gustafsson, C. ;
Nordstrom, F. ;
Persson, E. ;
Brynolfsson, J. ;
Olsson, L. E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (08) :2976-2989
[9]   CORRECTION FOR GEOMETRIC DISTORTION IN ECHO-PLANAR IMAGES FROM B-0 FIELD VARIATIONS [J].
JEZZARD, P ;
BALABAN, RS .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (01) :65-73
[10]   INTERNAL FIDUCIAL MARKERS AND SUSCEPTIBILITY EFFECTS IN MRI-SIMULATION AND MEASUREMENT OF SPATIAL ACCURACY [J].
Jonsson, Joakim H. ;
Garpebring, Anders ;
Karlsson, Magnus G. ;
Nyholm, Tufve .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05) :1612-1618