A "Step-Ramp-Step" Protocol to Identify the Maximal Metabolic Steady State

被引:59
|
作者
Iannetta, Danilo [1 ]
Inglis, Erin Calaine [1 ]
Pogliaghi, Silvia [2 ]
Murias, Juan M. [1 ]
Keir, Daniel A. [3 ]
机构
[1] Univ Calgary, Fac Kinesiol, KNB 434,2500 Univ Dr NW, Calgary, AB T2N 1N4, Canada
[2] Univ Verona, Dept Neurosci Biomed & Movement, Verona, Italy
[3] Univ Hlth Network, Dept Med, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
RESPIRATORY COMPENSATION POINT; EXERCISE PRESCRIPTION; AEROBIC; CARDIOPULMONARY EXERCISE TEST; CRITICAL POWER; O-2 UPTAKE KINETICS; CRITICAL POWER; RESPIRATORY COMPENSATION; EXERCISE; HETEROGENEITY; THRESHOLD; RESPONSES; FATIGUE;
D O I
10.1249/MSS.0000000000002343
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The oxygen uptake ((V)over dotO(2)) at the respiratory compensation point (RCP) closely identifies with the maximal metabolic steady state. However, the power output (PO) at RCP cannot be determined from contemporary ramp-incremental exercise protocols. Purpose: This study aimed to test the efficacy of a "step-ramp-step" (SRS) cycling protocol for estimating the PO at RCP and the validity of RCP as a maximal metabolic steady-state surrogate. Methods: Ten heathy volunteers (5 women; age: 30 +/- 7 yr; (V)over dotO(2max): 54 +/- 6 mL.kg(-1).min(-1)) performed in the following series: a moderate step transition to 100 W (MOD), ramp (30 W.min(-1)), and after 30 min of recovery, step transition to similar to 50% POpeak (HVY). Ventilatory and gas exchange data from the ramp were used to identify the (V)over dotO(2) at lactate threshold (LT) and RCP. The PO at LT was determined by the linear regression of the (V)over dotO(2) versus PO relationship after adjusting ramp data by the difference between the ramp PO at the steady-state (V)over dotO(2) from MOD and 100W. Linear regression between the (V)over dotO(2)-PO values associated with LT and HVY provided, by extrapolation, the PO at RCP. Participants then performed 30-min constant-power tests at the SRS-estimated RCP and 5% above this PO. Results: All participants completed 30min of constant-power exercise at the SRS-estimated RCP achieving steady-state (V)over dotO(2) of 3176 +/- 595 mL.min(-1) that was not different (P = 0.80) from the ramp-identified RCP (3095 +/- 570 mL.min(-1)) and highly consistent within participants (bias = -26 mL.min(-1), r = 0.97, coefficient of variation = 2.3% +/- 2.8%). At 5% above the SRS-estimated RCP, four participants could not complete 30 min and all, but two exhibited non-steady-state responses in blood lactate and (V)over dotO(2). Conclusions: In healthy individuals cycling at their preferred cadence, the SRS protocol and the RCP are capable of accurately predicting the PO associated with maximal metabolic steady state.
引用
收藏
页码:2011 / 2019
页数:9
相关论文
共 31 条
  • [1] A "Step-Ramp-Step" Protocol to Identify Running Speed and Power Associated with the Maximal Metabolic Steady State
    Van Rassel, Cody R.
    Ajayi, Oluwatimilehin O.
    Sales, Kate M.
    Azevedo, Rafael A.
    Murias, Juan M.
    Macinnis, Martin J.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (03) : 534 - 547
  • [2] Evaluation of the "Step-Ramp-Step" Protocol: Accurate Aerobic Exercise Prescription with Different Steps and Ramp Slopes
    Mackie, Mary Z.
    Iannetta, Danilo
    Keir, Daniel A.
    Murias, Juan M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (05) : 990 - 998
  • [3] A modified step-ramp-step protocol to prescribe constant-speed exercise in treadmill running
    Faricier, Robin
    Micheli, Lorenzo
    Guluzade, Nasimi A.
    Murias, Juan M.
    Keir, Daniel A.
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2024, 124 (11) : 3445 - 3455
  • [4] Ramp vs. step tests: valid alternatives to determine the maximal lactate steady-state intensity?
    Kevin Caen
    Silvia Pogliaghi
    Maarten Lievens
    Kobe Vermeire
    Jan G. Bourgois
    Jan Boone
    European Journal of Applied Physiology, 2021, 121 : 1899 - 1907
  • [5] Ramp vs. step tests: valid alternatives to determine the maximal lactate steady-state intensity?
    Caen, Kevin
    Pogliaghi, Silvia
    Lievens, Maarten
    Vermeire, Kobe
    Bourgois, Jan G.
    Boone, Jan
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (07) : 1899 - 1907
  • [6] Identification of maximal steady-state metabolic rate by the change in muscle oxygen saturation
    Matthews, Ian R.
    Heenan, Logan J.
    Fisher, Kathleen G.
    Flood, Emma F.
    Wehrman, Logan W.
    Kirby, Brett S.
    Wilkins, Brad W.
    JOURNAL OF APPLIED PHYSIOLOGY, 2023, 134 (06) : 1349 - 1358
  • [7] Methodological Reconciliation of CP and MLSS and Their Agreement with the Maximal Metabolic Steady State
    Iannetta, Danilo
    Ingram, Christina P.
    Keir, Daniel A.
    Murias, Juan M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2022, 54 (04) : 622 - 632
  • [8] Effects of step duration in incremental ramp protocols on peak power and maximal oxygen consumption
    Adami, Alessandra
    Sivieri, Andrea
    Moia, Christian
    Perini, Renza
    Ferretti, Guido
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2013, 113 (10) : 2647 - 2653
  • [9] Neuromuscular and metabolic comparisons between ramp and step incremental cycle ergometer tests
    Zuniga, Jorge M.
    Housh, Terry J.
    Camic, Clayton L.
    Bergstrom, Haley C.
    Traylor, Daniel A.
    Schmidt, Richard J.
    Johnson, Glen O.
    MUSCLE & NERVE, 2013, 47 (04) : 555 - 560
  • [10] Sex differences in the maximal metabolic steady state of fitness-matched women and men
    Wilkins, Brad W.
    Fisher, Kathleen G.
    Flood, Emma F.
    Heenan, Logan J.
    Matthews, Ian R.
    JOURNAL OF APPLIED PHYSIOLOGY, 2025, 138 (02) : 612 - 622