Efficient Fat Suppression by Slice-Selection Gradient Reversal in Twice-Refocused Diffusion Encoding

被引:53
作者
Nagy, Zoltan [1 ]
Weiskopf, Nikolaus [1 ]
机构
[1] UCL, Inst Neurol, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
关键词
diffusion imaging; diffusion tensor imaging; fat suppression; chemical shift artifact; slice-selection gradient;
D O I
10.1002/mrm.21746
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Most diffusion imaging sequences rely on single-shot echo-planar imaging (EPI) for spatial encoding since it is the fastest acquisition available. However, it is sensitive to chemical-shift artifacts due to the low bandwidth in the phase-encoding direction, making fat suppression necessary. Often, spectral-selective RF pulses followed by gradient spoiling are used to selectively saturate the fat signal. This lengthens the acquisition time and increases the specific absorption rate (SAR). However, in pulse sequences that contain two slice-selective 180 degrees refocusing pulses, the slice-selection gradient reversal (SSGR) method of fat suppression can be implemented; i.e., using slice-selection gradients of opposing polarity for the two refocusing pulses. We combined this method with the twice-refocused spin-echo sequence for diffusion encoding and tested its performance in both phantoms and in vivo. Unwanted fat signal was entirely suppressed with this method without affecting the water signal intensity or the slice profile. Magn Reson Med 60: 1256-1260, 2008. (C) 2008 Wiley-Liss, Inc.
引用
收藏
页码:1256 / 1260
页数:5
相关论文
共 20 条
[11]   A CHEMICAL-SHIFT SELECTIVE INVERSION RECOVERY SEQUENCE FOR FAT-SUPPRESSED MRI - THEORY AND EXPERIMENTAL VALIDATION [J].
KALDOUDI, E ;
WILLIAMS, SCR ;
BARKER, GJ ;
TOFTS, PS .
MAGNETIC RESONANCE IMAGING, 1993, 11 (03) :341-355
[12]   MR IMAGING OF INTRAVOXEL INCOHERENT MOTIONS - APPLICATION TO DIFFUSION AND PERFUSION IN NEUROLOGIC DISORDERS [J].
LEBIHAN, D ;
BRETON, E ;
LALLEMAND, D ;
GRENIER, P ;
CABANIS, E ;
LAVALJEANTET, M .
RADIOLOGY, 1986, 161 (02) :401-407
[13]  
McRobbie D.W., 2003, MRI PICTURE PROTON
[14]   EARLY DETECTION OF REGIONAL CEREBRAL-ISCHEMIA IN CATS - COMPARISON OF DIFFUSION-WEIGHTED AND T2-WEIGHTED MRI AND SPECTROSCOPY [J].
MOSELEY, ME ;
COHEN, Y ;
MINTOROVITCH, J ;
CHILEUITT, L ;
SHIMIZU, H ;
KUCHARCZYK, J ;
WENDLAND, MF ;
WEINSTEIN, PR .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :330-346
[15]   Normal brain maturation during childhood: Developmental trends characterized with diffusion-tensor imaging [J].
Mukherjee, P ;
Miller, JH ;
Shimony, JS ;
Conturo, TE ;
Lee, BCP ;
Almli, CR ;
McKinstry, RC .
RADIOLOGY, 2001, 221 (02) :349-358
[16]   Evidence for cortical "disconnection" as a mechanism of age-related cognitive decline [J].
O'Sullivan, M ;
Jones, DK ;
Summers, PE ;
Morris, RG ;
Williams, SCR ;
Markus, HS .
NEUROLOGY, 2001, 57 (04) :632-638
[17]   Reduction of eddy-current-induced distortion in diffusion MRI using a twice-refocused spin echo [J].
Reese, TG ;
Heid, O ;
Weisskoff, RM ;
Wedeen, VJ .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :177-182
[18]   SPIN DIFFUSION MEASUREMENTS: SPIN ECHOES IN THE PRESENCE OF A TIME-DEPENDENT FIELD GRADIENT [J].
STEJSKAL, EO ;
TANNER, JE .
JOURNAL OF CHEMICAL PHYSICS, 1965, 42 (01) :288-+
[19]  
THESEN S, 2002, P 11 ANN M ISMRM TOR
[20]   ECHO-PLANAR IMAGING OF INTRAVOXEL INCOHERENT MOTION [J].
TURNER, R ;
LEBIHAN, D ;
MAIER, J ;
VAVREK, R ;
HEDGES, LK ;
PEKAR, J .
RADIOLOGY, 1990, 177 (02) :407-414