Operating Room Traffic Increases Aerosolized Particles and Compromises the Air Quality: A Simulated Study

被引:37
作者
Rezapoor, Maryam [1 ]
Alvand, Abtin [1 ]
Jacek, Elzbieta [1 ]
Paziuk, Taylor [1 ]
Maltenfort, Mitchell G. [1 ]
Parvizi, Javad [1 ]
机构
[1] Thomas Jefferson Univ, Rothman Inst, Philadelphia, PA 19107 USA
关键词
periprosthetic joint infection; operating room; air quality; laminar air flow; door opening; OR traffic; PERIPROSTHETIC JOINT INFECTION; SURGICAL SITE INFECTION; POSTOPERATIVE INFECTION; RISK-FACTORS; TOTAL HIP; KNEE ARTHROPLASTY; ULTRACLEAN AIR; UNITED-STATES; REPLACEMENT; CONTAMINATION;
D O I
10.1016/j.arth.2017.10.012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Strategies to prevent bacterial fallout and reduce particle count in the operating room (OR) are key components of preventing periprosthetic joint infection. Although OR traffic control is an important factor, a quantitative study has not been performed to investigate the influence of personnel and door opening on OR air quality. This simulated study aimed to examine the influence of these 2 factors on particle density in OR with and without the laminar air flow (LAF). Methods: Both experiments took place within an empty OR of an arthroplasty unit equipped with an LAF system. First, the number of particles in the air was counted using a particle counting apparatus while 9 persons entered the room, one every 15 minutes. Second, the door was opened and closed starting with zero door openings per minute and increasing to 4 in 15-minute increments. Both experiments were performed once with the LAF turned on and once without. Results: The number of personnel in the OR and the number of door openings per minute correlate with the density of particles. Both relationships were significantly reduced by turning the LAF on (correlation coefficients <0.4). With the LAF being turned on, the particle density per person decreased from 211.19 to 18.19 particles/ft(3) (P < .001) and the particle density per rate of door openings declined from 117.80 to 1.90 particles/ft(3) (P = .017). Conclusion: This study confirms that personnel and door opening are a major source of particles in the OR air. Controlling traffic is critical for reduction of particles and is likely to be a key preventative strategy in reducing periprosthetic joint infection. LAF is protective against the negative influence of number of people and door openings. (C) 2017 Published by Elsevier Inc.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 40 条
  • [31] Bacteria-carrying particles diffusion in the operating room due to the interaction between human thermal plume and ventilation systems: An experimental-numerical simulation study
    Liu, Zhijian
    Di Yin
    Hu, Lina
    He, Junzhou
    Cao, Guoqing
    ENERGY AND BUILDINGS, 2022, 270
  • [32] Operating room air delivery design to protect patient and surgical site results in particles released at surgical table having greater concentration along walls of the room than at the instrument tray
    Wagner, Jennifer A.
    Dexter, Franklin
    Greeley, Damon G.
    Schreiber, Kevin
    AMERICAN JOURNAL OF INFECTION CONTROL, 2021, 49 (05) : 593 - 596
  • [33] Developing and optimizing air curtains for reducing bacteria-carrying particles in operating rooms: A numerical simulation study
    Liu, Jiangbo
    Zhang, Yubin
    Zheng, Xiaohong
    Qian, Hua
    JOURNAL OF BUILDING ENGINEERING, 2025, 104
  • [34] Air quality and the risk of acute atrial fibrillation (EP-PARTICLES study): a nationwide study in Poland
    Kurasz, Anna
    Lip, Gregory Y. H.
    Swieczkowski, Michal
    Tomaszuk-Kazberuk, Anna
    Dobrzycki, Slawomir
    Kuzma, Lukasz
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2025,
  • [35] EXPERIMENTAL STUDY OF MULTI-FIN HEAT PIPE HEAT EXCHANGER FOR ENERGY EFFICIENCY IN OPERATING ROOM AIR SYSTEMS
    Muhammaddiyah, Syahrul
    Winarta, Adi
    Putra, Nandy
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2018, 9 (02) : 422 - 429
  • [36] A Study of Traffic Emissions Based on Floating Car Data for Urban Scale Air Quality Applications
    Russo, Felicita
    Villani, Maria Gabriella
    D'Elia, Ilaria
    D'Isidoro, Massimo
    Liberto, Carlo
    Piersanti, Antonio
    Tinarelli, Gianni
    Valenti, Gaetano
    Ciancarella, Luisella
    ATMOSPHERE, 2021, 12 (08)
  • [37] Observational study on hospital building heritage and microbiological air quality in the orthopedic operating theater: the IM.PA.C.T. Project
    D'Amico, A.
    Montagna, M. T.
    Caggiano, G.
    De Giglio, O.
    Rutigliano, S.
    Lopuzzo, M.
    Mascipinto, S.
    Napoli, C.
    Curra, E.
    D'Alessandro, D.
    ANNALI DI IGIENE MEDICINA PREVENTIVA E DI COMUNITA, 2019, 31 (05): : 482 - 495
  • [38] Tree bark as bioindicator of metal accumulation from road traffic and air quality map: A case study of Chiang Mai, Thailand
    Janta, Rungruang
    Chantara, Somporn
    ATMOSPHERIC POLLUTION RESEARCH, 2017, 8 (05) : 956 - 967
  • [39] Evaluation of laminar airflow heating, ventilation, and air conditioning system for particle dispersion control in operating room including staffs: A non-Boussinesq Lagrangian study
    Amiraslanpour, Mojtaba
    Ghazanfarian, Jafar
    Nabaei, Hamidreza
    Taleghani, Mohammad Hassan
    JOURNAL OF BUILDING PHYSICS, 2021, 45 (02) : 236 - 264
  • [40] Influence of long-range transport dust particles on local air quality: A case study on Asian dust episodes in Taipei during the spring of 2002
    Chou, CCK
    Lin, CY
    Chen, TK
    Hsu, SC
    Lung, SC
    Liu, SC
    Young, CY
    TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2004, 15 (05): : 881 - 899