Effect of Computed Tomography Scanning Parameters on Gold Nanoparticle and Iodine Contrast

被引:86
作者
Galper, Merav Weill [1 ]
Saung, May Tun [1 ]
Fuster, Valentin [2 ,3 ]
Roessl, Ewald [4 ]
Thran, Axel [4 ]
Proksa, Roland [4 ]
Fayad, Zahi Adel [1 ]
Cormode, David Peter [1 ]
机构
[1] Mt Sinai Sch Med, Translat & Mol Imaging Inst, New York, NY 10029 USA
[2] Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, New York, NY 10029 USA
[3] CNIC, Madrid, Spain
[4] Philips Res Europe, Hamburg, Germany
基金
美国国家卫生研究院;
关键词
computed tomography; gold nanoparticles; contrast agents; iodine; BLOOD-POOL; AGENT; CT; MICE; DELIVERY;
D O I
10.1097/RLI.0b013e3182562ab9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Gold nanoparticles (gold-NPs) have lately been proposed as alternative contrast agents to iodine-based contrast agents (iodine-CA) for computed tomography (CT) angiography. The aims of this study were to confirm an appropriate environment in which to evaluate such novel contrast agents, to investigate the comparative contrast of iodine-CA versus gold-NP, and to determine optimal scanning parameters for gold-NP. Materials and Methods: Three different clinical scanners were used to acquire CT images. A range of concentrations (10 mM to 1.5 M) of gold-NP and iodine-CA were scanned with varying x-ray tube voltages and currents, reconstruction kernels, protocols, and scanner models. The different environments investigated were air, water, and water with a bone simulant (Ca-3(PO4)(2)). Regression coefficients were derived from the attenuation values plotted against concentration and compared for statistical significance using t values. Results: As expected, contrast was linearly related to concentrations up to 500 to 1000 mM, depending on the conditions used, whereupon a plateau of 3000 Hounsfield units was reached. Attenuation was significantly different depending on the environment used (air, water, or water and bone simulant). Contrast is dependent on the x-ray tube voltage used, with the contrast produced from iodine-CA sharply declining with increasing voltage, whereas the contrast of gold-NP varied less with tube voltage but was maximal at 120 kV in water with bone simulant. Current, reconstruction kernels, protocols, and scanner model had less effect on contrast. Conclusion: Water with a bone simulant is a preferable environment for evaluating novel cardiac CT contrast agents. Relative iodine-CA versus gold-NP contrast is dependent on the scanning conditions used. Optimal scanning conditions for gold-NP will likely use an x-ray tube voltage of 120 kV.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [21] Gold Nanoparticle Parameters Play an Essential Role as CT Imaging Contrast Agents
    Asadinezhad, Mohsen
    Azimian, Hosein
    Ghadiri, Hossein
    Khademi, Sara
    JOURNAL OF NANOSTRUCTURES, 2021, 11 (04) : 668 - 677
  • [22] Comparison of Gold Nanoparticles and Iodinated Contrast Media in Radiation Dose Reduction and Contrast Enhancement in Computed Tomography
    Taghavi, Hamid
    Bakhshandeh, Mohsen
    Montazerabadi, Alireza
    Moghadam, Hossein Nazari
    Shahri, Seyyed Behnam Mazloom
    Keshtkar, Mohammad
    IRANIAN JOURNAL OF RADIOLOGY, 2020, 17 (01)
  • [23] Computed tomography lung iodine contrast mapping by image registration and subtraction
    Goatman, Keith
    Plakas, Costas
    Schuijf, Joanne
    Beveridge, Erin
    Prokop, Mathias
    MEDICAL IMAGING 2014: IMAGE PROCESSING, 2014, 9034
  • [24] Evaluation of size, morphology, concentration, and surface effect of gold nanoparticles on X-ray attenuation in computed tomography
    Khademi, Sara
    Sarkar, Saeed
    Kharrazi, Sharmin
    Amini, Seyed Mohammad
    Shakeri-Zadeh, Ali
    Ay, Mohammad Reza
    Ghadiri, Hossein
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 127 - 133
  • [25] Effect of Different Iodine Concentrations on Patient-Reported Discomfort in Contrast-Enhanced Computed Tomography: A Prospective Comparative Trial
    Vahldiek, Janis Lucas
    Schaafs, Lars-Arne
    Niehues, Birgit K.
    Hamm, Bernd
    Niehues, Stefan Markus
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2020, 192 (10): : 945 - 951
  • [26] Glutathione-Responsive Gold Nanoparticles as Computed Tomography Contrast Agents for Hepatic Diseases
    Yoo, Dohyun
    Jung, Wonsik
    Son, Youngju
    Jon, Sangyong
    ACS APPLIED BIO MATERIALS, 2021, 4 (05) : 4486 - 4494
  • [27] Evaluation of Tumor Microenvironment in an Animal Model using a Nanoparticle Contrast Agent in Computed Tomography Imaging
    Ghaghada, Ketan B.
    Badea, Cristian T.
    Karumbaiah, Lohitash
    Fettig, Nicole
    Bellamkonda, Ravi V.
    Johnson, G. A.
    Annapragada, Ananth
    ACADEMIC RADIOLOGY, 2011, 18 (01) : 20 - 30
  • [28] Mass-transfer based modeling to investigate iodine staining effects for enhanced contrast X-ray computed tomography
    Li, Zhi-Heng
    Yan, Fei
    Ketcham, Richard A.
    Colbert, Matthew W.
    Clarke, Julia A.
    PALAEOWORLD, 2019, 28 (04) : 562 - 571
  • [29] A comparison of the use of contrast media with different iodine concentrations for enhanced computed tomography
    Du, Yu
    Wang, Ya-Ning
    Wang, Qi
    Qi, Xiao-Hui
    Shi, Gao-Feng
    Jia, Li-Tao
    Wang, Xiang-Ming
    Shi, Jia-Bao
    Liu, Feng-Yun
    Wang, Li-Jia
    Liu, Xiang
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [30] Characterization and comparison of imaging contrast enhancement with PEG-functionalized gold nanoparticles in kV cone beam computed tomography and computed tomography imaging
    Gray, Tara
    Bassiri, Nema
    David, Shaquan
    Patel, Devanshi Yogeshkumar
    Abdul-Moqueet, Mohammad
    Kirby, Neil
    Mayer, Kathryn M.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04)