Effect of Computed Tomography Scanning Parameters on Gold Nanoparticle and Iodine Contrast

被引:86
|
作者
Galper, Merav Weill [1 ]
Saung, May Tun [1 ]
Fuster, Valentin [2 ,3 ]
Roessl, Ewald [4 ]
Thran, Axel [4 ]
Proksa, Roland [4 ]
Fayad, Zahi Adel [1 ]
Cormode, David Peter [1 ]
机构
[1] Mt Sinai Sch Med, Translat & Mol Imaging Inst, New York, NY 10029 USA
[2] Mt Sinai Sch Med, Zena & Michael A Wiener Cardiovasc Inst, New York, NY 10029 USA
[3] CNIC, Madrid, Spain
[4] Philips Res Europe, Hamburg, Germany
基金
美国国家卫生研究院;
关键词
computed tomography; gold nanoparticles; contrast agents; iodine; BLOOD-POOL; AGENT; CT; MICE; DELIVERY;
D O I
10.1097/RLI.0b013e3182562ab9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Gold nanoparticles (gold-NPs) have lately been proposed as alternative contrast agents to iodine-based contrast agents (iodine-CA) for computed tomography (CT) angiography. The aims of this study were to confirm an appropriate environment in which to evaluate such novel contrast agents, to investigate the comparative contrast of iodine-CA versus gold-NP, and to determine optimal scanning parameters for gold-NP. Materials and Methods: Three different clinical scanners were used to acquire CT images. A range of concentrations (10 mM to 1.5 M) of gold-NP and iodine-CA were scanned with varying x-ray tube voltages and currents, reconstruction kernels, protocols, and scanner models. The different environments investigated were air, water, and water with a bone simulant (Ca-3(PO4)(2)). Regression coefficients were derived from the attenuation values plotted against concentration and compared for statistical significance using t values. Results: As expected, contrast was linearly related to concentrations up to 500 to 1000 mM, depending on the conditions used, whereupon a plateau of 3000 Hounsfield units was reached. Attenuation was significantly different depending on the environment used (air, water, or water and bone simulant). Contrast is dependent on the x-ray tube voltage used, with the contrast produced from iodine-CA sharply declining with increasing voltage, whereas the contrast of gold-NP varied less with tube voltage but was maximal at 120 kV in water with bone simulant. Current, reconstruction kernels, protocols, and scanner model had less effect on contrast. Conclusion: Water with a bone simulant is a preferable environment for evaluating novel cardiac CT contrast agents. Relative iodine-CA versus gold-NP contrast is dependent on the scanning conditions used. Optimal scanning conditions for gold-NP will likely use an x-ray tube voltage of 120 kV.
引用
收藏
页码:475 / 481
页数:7
相关论文
共 50 条
  • [1] Effect of Gold Nanoparticle Size on Their Properties as Contrast Agents for Computed Tomography
    Dong, Yuxi C.
    Hajfathalian, Maryam
    Maidment, Portia S. N.
    Hsu, Jessica C.
    Naha, Pratap C.
    Si-Mohamed, Salim
    Breuilly, Marine
    Kim, Johoon
    Chhour, Peter
    Douek, Philippe
    Litt, Harold I.
    Cormode, David P.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [2] Gold nanoparticles as contrast agents in x-ray imaging and computed tomography
    Cole, Lisa E.
    Ross, Ryan D.
    Tilley, Jennifer M. R.
    Vargo-Gogola, Tracy
    Roeder, Ryan K.
    NANOMEDICINE, 2015, 10 (02) : 321 - 341
  • [3] Composite Iodine-gold Nanoparticles as a Contrast Agent in Computed Tomography
    Haghighi, Rezvan Ravanfar
    Zarei, Fariba
    Moshiri, Samira
    Jafari, Anahita
    Chatterjee, Sabyasachi
    Akondi, Vyas
    Chatterjee, Vani Vardhan
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 448 - 455
  • [4] Nanoparticle contrast-enhanced computed tomography of sporadic aortic aneurysm and dissection: Effect of nanoparticle size and contrast agent dose
    Devkota, Laxman
    Zhang, Chen
    Vela, Deborah
    Sarkar, Poonam
    Bhandari, Prajwal
    Starosolsk, Zbigniew
    Menon, Renuka
    Milewicz, Dianna M.
    Shen, Ying H.
    Lemaire, Scott A.
    Ghaghada, Ketan B.
    THERANOSTICS, 2025, 15 (08): : 3462 - 3473
  • [5] Flash nanoprecipitation of hafnia nanoparticle computed tomography contrast agent
    Liu, Sitong
    Po, Matthew
    Heshmat, Anahita
    Anguish, Evan
    Andrew, Jennifer
    Rinaldi-Ramos, Carlos M.
    JOURNAL OF NANOPARTICLE RESEARCH, 2023, 25 (06)
  • [6] Flash nanoprecipitation of hafnia nanoparticle computed tomography contrast agent
    Sitong Liu
    Matthew Po
    Anahita Heshmat
    Evan Anguish
    Jennifer Andrew
    Carlos M Rinaldi-Ramos
    Journal of Nanoparticle Research, 2023, 25
  • [7] Gold-coated plant virus as computed tomography imaging contrast agent
    Aljabali, Alaa A. A.
    Al Zoubi, Mazhar S.
    Al-Batanyeh, Khalid M.
    Al-Radaideh, Ali
    Obeid, Mohammad A.
    Al Sharabi, Abeer
    Alshaer, Walhan
    AbuFares, Bayan
    Al-Zanatil, Tasnim
    Tambuwala, Murtaza M.
    Akbar, Naveed
    Evans, David J.
    BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2019, 10 : 1983 - 1993
  • [8] Design of functionalized gold nanoparticle probes for computed tomography imaging
    Silvestri, Alessandro
    Zambelli, Vanessa
    Ferretti, Anna M.
    Salerno, Domenico
    Bellani, Giacomo
    Polito, Laura
    CONTRAST MEDIA & MOLECULAR IMAGING, 2016, 11 (05) : 405 - 414
  • [9] Computed tomography with iodine-free contrast media
    Zwicker, C
    Hering, M
    Langer, R
    EUROPEAN RADIOLOGY, 1997, 7 (07) : 1123 - 1126
  • [10] Synthesis and characterization of ethosomal contrast agents containing iodine for computed tomography (CT) imaging applications
    Shin, Hanjin
    Cho, Young-Min
    Lee, Kangtaek
    Lee, Chang-Ha
    Choi, Byoung Wook
    Kim, Bumsang
    JOURNAL OF LIPOSOME RESEARCH, 2014, 24 (02) : 124 - 129