Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty

被引:71
|
作者
Niki, Yasuo [1 ]
Nagura, Takeo [2 ]
Nagai, Katsuya [1 ]
Kobayashi, Shu [1 ]
Harato, Kengo [1 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Clin Biomech, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
关键词
Kinematically aligned total knee arthroplasty; Knee adduction moment; Gait analysis; Joint line obliquity; Constitutional varus; TOE-IN GAIT; OSTEOARTHRITIS; ALIGNMENT; JOINT; VARUS; WALKING; FLEXION; STRESS; LOAD;
D O I
10.1007/s00167-017-4788-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee adduction moment (KAM) has been recognized as a good clinical surrogate for medial tibiofemoral joint loading and is associated with implant durability after total knee arthroplasty (TKA). This study aimed to examine the effects of joint line obliquity in kinematically aligned TKA (KA-TKA) on KAM during gait. The study enrolled 21 knees from 18 patients who underwent cylindrical axis reference KA-TKA and a matched group of 21 knees from 18 patients who underwent mechanically aligned (MA)-TKA as controls. Gait analyses were performed the day before TKA and at an overall mean of 2.6 years postoperatively. First peak KAM and variables associated with frontal knee kinetics were determined and compared between groups. In KA-TKA, the proximal tibia was resected with 3.4A degrees +/- 1.5A degrees of varus in relation to the mechanical axis, and the final femorotibial shaft axis was 176.7A degrees +/- 3.8A degrees with KA-TKA and 174.4A degrees +/- 3.0A degrees with MA-TKA. KAM was significantly smaller with KA-TKA than with MA-TKA (p < 0.032). Regarding variables affecting KAM, significant differences were evident between the two TKAs for knee adduction angle (p = 0.0021), lever arm (p = 0.028), and Delta lever arm (p = 0.0001). In KA-TKA, joint line obliquity reduced peak KAM during gait, despite slight varus limb alignment, and this reduced KAM in KA-TKA can tolerate constitutional varus alignment. In clinical settings, KA-TKA thus represents a promising technical option for patients with large coronal bowing of the shaft carrying a risk of increased KAM after TKA. III.
引用
收藏
页码:1629 / 1635
页数:7
相关论文
共 50 条
  • [31] Clinical outcomes of unicompartmental knee arthroplasty and total knee arthroplasty in the same patient
    Hao, Yu
    Li, Jia
    Feng, Yamei
    Huang, Haiyang
    Dong, Wei
    Liu, Guobin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (11) : 4791 - 4800
  • [32] The Knee Adduction Moment During Gait is Associated With the Adduction Angle Measured During Computer-Assisted Total Knee Arthroplasty
    Roda, Richard D.
    Wilson, Janie L. Astephen
    Wilson, David A. J.
    Richardson, Glen
    Dunbar, Michael J.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (06) : 1244 - 1250
  • [33] Who Will Benefit From Kinematically Aligned Total Knee Arthroplasty? Perspectives on Patient-Reported Outcome Measures
    Niki, Yasuo
    Nagura, Takeo
    Kobayashi, Shu
    Udagawa, Kazuhiko
    Harato, Kengo
    JOURNAL OF ARTHROPLASTY, 2020, 35 (02) : 438 - +
  • [34] What clinical characteristics and radiographic parameters are associated with patellofemoral instability after kinematically aligned total knee arthroplasty?
    Nedopil, Alexander J.
    Howell, Stephen M.
    Hull, Maury L.
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (02) : 283 - 291
  • [35] What mechanisms are associated with tibial component failure after kinematically-aligned total knee arthroplasty?
    Nedopil, Alexander J.
    Howell, Stephen M.
    Hull, Maury L.
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (08) : 1561 - 1569
  • [36] Decrease of tibial tuberosity trochlear groove distance following mechanically aligned total knee arthroplasty
    Zimmermann, Stefan M.
    Scherrer, Yves
    Zaleski, Martin
    Jentzsch, Thorsten
    Fucentese, Sandro F.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (03) : 1162 - 1167
  • [37] Calipered Kinematically Aligned Total Knee Arthroplasty: An Accurate Technique That Improves Patient Outcomes and Implant Survival
    Howell, Stephen M.
    ORTHOPEDICS, 2019, 42 (03) : 126 - +
  • [38] Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances
    Blakeney, William
    Beaulieu, Yann
    Puliero, Benjamin
    Kiss, Marc-Olivier
    Vendittoli, Pascal-Andre
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (05) : 1532 - 1541
  • [39] Bone resection for mechanically aligned total knee arthroplasty creates frequent gap modifications and imbalances
    William Blakeney
    Yann Beaulieu
    Benjamin Puliero
    Marc-Olivier Kiss
    Pascal-André Vendittoli
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 1532 - 1541
  • [40] Restoration of the native tibial joint line obliquity in total knee arthroplasty with inverse kinematic alignment does not increase knee adduction moments
    de Grave, Philip Winnock
    Van Criekinge, Tamaya
    Luyckx, Thomas
    Moreels, Robin
    Gunst, Paul
    Claeys, Kurt
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (11) : 4692 - 4704