Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty

被引:71
|
作者
Niki, Yasuo [1 ]
Nagura, Takeo [2 ]
Nagai, Katsuya [1 ]
Kobayashi, Shu [1 ]
Harato, Kengo [1 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Tokyo, Japan
[2] Keio Univ, Sch Med, Dept Clin Biomech, Shinjuku Ku, 35 Shinanomachi, Tokyo 1608582, Japan
关键词
Kinematically aligned total knee arthroplasty; Knee adduction moment; Gait analysis; Joint line obliquity; Constitutional varus; TOE-IN GAIT; OSTEOARTHRITIS; ALIGNMENT; JOINT; VARUS; WALKING; FLEXION; STRESS; LOAD;
D O I
10.1007/s00167-017-4788-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee adduction moment (KAM) has been recognized as a good clinical surrogate for medial tibiofemoral joint loading and is associated with implant durability after total knee arthroplasty (TKA). This study aimed to examine the effects of joint line obliquity in kinematically aligned TKA (KA-TKA) on KAM during gait. The study enrolled 21 knees from 18 patients who underwent cylindrical axis reference KA-TKA and a matched group of 21 knees from 18 patients who underwent mechanically aligned (MA)-TKA as controls. Gait analyses were performed the day before TKA and at an overall mean of 2.6 years postoperatively. First peak KAM and variables associated with frontal knee kinetics were determined and compared between groups. In KA-TKA, the proximal tibia was resected with 3.4A degrees +/- 1.5A degrees of varus in relation to the mechanical axis, and the final femorotibial shaft axis was 176.7A degrees +/- 3.8A degrees with KA-TKA and 174.4A degrees +/- 3.0A degrees with MA-TKA. KAM was significantly smaller with KA-TKA than with MA-TKA (p < 0.032). Regarding variables affecting KAM, significant differences were evident between the two TKAs for knee adduction angle (p = 0.0021), lever arm (p = 0.028), and Delta lever arm (p = 0.0001). In KA-TKA, joint line obliquity reduced peak KAM during gait, despite slight varus limb alignment, and this reduced KAM in KA-TKA can tolerate constitutional varus alignment. In clinical settings, KA-TKA thus represents a promising technical option for patients with large coronal bowing of the shaft carrying a risk of increased KAM after TKA. III.
引用
收藏
页码:1629 / 1635
页数:7
相关论文
共 50 条
  • [1] Kinematically aligned total knee arthroplasty reduces knee adduction moment more than mechanically aligned total knee arthroplasty
    Yasuo Niki
    Takeo Nagura
    Katsuya Nagai
    Shu Kobayashi
    Kengo Harato
    Knee Surgery, Sports Traumatology, Arthroscopy, 2018, 26 : 1629 - 1635
  • [2] Kinematically aligned total knee arthroplasty restores more native medial collateral ligament strain than mechanically aligned total knee arthroplasty
    Lim, Dohyung
    Kwak, Dai-Soon
    Kim, Minji
    Kim, Seoyeong
    Cho, Ho-Jung
    Choi, Jae Hyuk
    Koh, In Jun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2022, 30 (08) : 2815 - 2823
  • [3] Kinematically Versus Mechanically Aligned Total Knee Arthroplasty
    Dossett, H. Gene
    Swartz, George J.
    Estrada, Nicolette A.
    LeFevre, George W.
    Kwasman, Bertram G.
    ORTHOPEDICS, 2012, 35 (02) : E160 - E169
  • [4] Kinematically aligned total knee arthroplasty reproduces more native rollback and laxity than mechanically aligned total knee arthroplasty: A matched pair cadaveric study
    Koh, In Jun
    Lin, Charles C.
    Patel, Nilay A.
    Chalmers, Christen E.
    Maniglio, Mauro
    Bin Han, Sung
    McGarry, Michelle H.
    Lee, Thay Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2019, 105 (04) : 605 - 611
  • [5] Radiological and clinical comparison of kinematically versus mechanically aligned total knee arthroplasty
    Matsumoto, T.
    Takayama, K.
    Ishida, K.
    Hayashi, S.
    Hashimoto, S.
    Kuroda, R.
    BONE & JOINT JOURNAL, 2017, 99-B (05) : 640 - 646
  • [6] Kinematically Aligned Total Knee Arthroplasty Using Medial Pivot Knee Prosthesis Enhances Medial Pivot Motion: A Comparative Kinematic Study With Mechanically Aligned Total Knee Arthroplasty
    Kaneda, Kazuya
    Niki, Yasuo
    Kuroyanagi, Yuji
    Kobayashi, Shu
    Harato, Kengo
    Iwama, Yu
    Nagura, Takeo
    ARTHROPLASTY TODAY, 2022, 13 : 24 - 28
  • [7] Limitations of the knee society score in kinematically aligned total knee arthroplasty
    Leica, Alexandra
    Sava, Manuel-Paul
    Khan, Zainab-Aqeel
    Hugli, Rolf W.
    Hirschmann, Michael T.
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [8] Restricted Kinematically Aligned Total Knee Arthroplasty Following Failed Oxford Unicompartmental Knee Arthroplasty
    Hayashi, Takuma
    Hiranaka, Takafumi
    Fujishiro, Takaaki
    Okamoto, Koji
    Koide, Motoki
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (09)
  • [9] Kinematically aligned total knee arthroplasty: alternative standardized technique?
    Matsumoto, Tomoyuki
    Takayama, Koji
    Ishida, Kazunari
    Hayashi, Shinya
    Hashimoto, Shingo
    Kuroda, Ryosuke
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5
  • [10] A randomized controlled trial comparing functional outcomes for navigated kinematically aligned total knee arthroplasty versus navigated mechanically aligned total knee arthroplasty THE MAKKRO TRIAL
    Sadekar, V. N.
    Datir, S.
    Allgar, V
    Sharma, H.
    BONE & JOINT OPEN, 2021, 2 (11): : 945 - 950