Synthesis and application of a peroxidase-like molecularly imprinted polymer based on hemin for selective determination of serotonin in blood serum

被引:47
作者
Rodrigues Santos, Wilney de Jesus [1 ]
Lima, Phabyanno Rodrigues [1 ]
Teixeira Tarley, Cesar Ricardo [2 ]
Hoehr, Nelci Fenalti [3 ]
Kubota, Lauro Tatsuo [1 ]
机构
[1] Univ Estadual Campinas, Inst Quim, Dept Quim Analit, BR-13084971 Campinas, SP, Brazil
[2] Univ Fed Alfenas, Dept Ciencias Exatas, BR-37130000 Alfenas, Brazil
[3] Univ Estadual Campinas, Fac Ciencias Med, Dept Patol Clin, BR-13081970 Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Serotonin; Hemin; Molecularly imprinted polymers; Amperometric detection; ANALYTICAL-CHEMISTRY; BIOMIMETIC POLYMERS; EXTRACTION; PRECONCENTRATION;
D O I
10.1016/j.aca.2008.10.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work reports the preparation of a molecularly imprinted polymer (MIP) for selective catalytic detection of serotonin (5-hydroxytryptamine, 5-HT). The process is based on the synthesis of polymers with hemin introduced as the catalytic center to mimic the active site of peroxidase. The copolymer MIP, containing artificial recognition sites for 5-HT, has been prepared by bulk polymerization using methacryl' acid (MAA) and hemin as the functional monomers, and ethylene glycol climethacrylate (EGDMA) as the cross-linker. For the determination of 5-HT, a flow injection analysis system coupled to an amperometric detector was optimized using multivariate analysis. The effects of different parameters, such as pH, buffer flow rate, buffer nature, peroxide concentration and sample volume were evaluated. After optimizing the experimental conditions, a linear response range from 1.0 up to 1000.0 mu mol L-1 was obtained with a sensitivity of 0.4 nA/mu mol L-1. The detection limit was found to be 0.30 mu mol L-1, while the precision value (n = 6) evaluated by relative standard deviation (R.S.D.) were, respectively, 1.3 and 1.7% for solutions of 50 and 750 mu mol L-1 of 5-HT. No interference was observed by structurally similar compounds (including epinephrine, cloparnine and norepinephrine), thus validating the good performance of the imprinted polymer. The method was applied for the determination of 5-HT in spiked blood serum samples. (C) 2008 Elsevier B.V. All rights reserve.
引用
收藏
页码:170 / 176
页数:7
相关论文
共 28 条
[1]  
Bergmeyer H.U., 1983, METHOD ENZYMAT AN, V1
[2]  
Bornscheurer U., 1999, HYDROLASES ORGANIC S
[3]   What makes a good biocatalyst? [J].
Cheetham, PSJ .
JOURNAL OF BIOTECHNOLOGY, 1998, 66 (01) :3-10
[4]   Electrochemical detection in bioanalysis [J].
Kissinger, PT .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :871-880
[5]   The development of biochemical engineering science in Europe [J].
Lilly, MD .
JOURNAL OF BIOTECHNOLOGY, 1997, 59 (1-2) :11-18
[6]   Concentration and extraction of sinomenine from herb and plasma using a molecularly imprinted polymer as the stationary phase [J].
Lin, LQ ;
Zhang, J ;
Fu, Q ;
He, LC ;
Li, YC .
ANALYTICA CHIMICA ACTA, 2006, 561 (1-2) :178-182
[7]   Amperometric detection of phenols using peroxidase-modified graphite electrodes [J].
Lindgren, A ;
Emneus, J ;
Ruzgas, T ;
Gorton, L ;
MarkoVarga, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :51-62
[8]   LIMIT OF DETECTION [J].
LONG, GL ;
WINEFORDNER, JD .
ANALYTICAL CHEMISTRY, 1983, 55 (07) :A712-+
[9]   Drug interactions of clinical significance with selective serotonin reuptake inhibitors [J].
Mitchell, PB .
DRUG SAFETY, 1997, 17 (06) :390-406
[10]  
Nozaki O, 1996, J BIOLUM CHEMILUM, V11, P309, DOI 10.1002/(SICI)1099-1271(199611)11:6<309::AID-BIO424>3.0.CO