Spot-scanning beam proton therapy vs intensity-modulated radiation therapy for ipsilateral head and neck malignancies: A treatment planning comparison

被引:70
作者
Kandula, Shravan [1 ]
Zhu, Xiaorong [2 ]
Garden, Adam S. [1 ]
Gillin, Michael [2 ]
Rosenthal, David I. [1 ]
Ang, Kie-Kian [1 ]
Mohan, Radhe [2 ]
Amin, Mayankkumar V. [1 ]
Garcia, John A. [1 ]
Wu, Richard [2 ]
Sahoo, Narayah [2 ]
Frank, Steven J. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
关键词
Proton therapy; Spot scanning; Single field uniform dose optimization; Radiation therapy; Head and neck malignancies; PARANASAL SINUS; CANCER; RADIOTHERAPY; CARCINOMA; PHOTON; STRATEGIES; TOLERANCE; TUMORS; IMRT;
D O I
10.1016/j.meddos.2013.05.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiation therapy for head and neck malignancies can have side effects that impede quality of life. Theoretically, proton therapy can reduce treatment-related morbidity by minimizing the dose to critical normal tissues. We evaluated the feasibility of spot-scanning proton therapy for head and neck malignancies and compared dosimetry between those plans and intensity-modulated radiation therapy (IMRT) plans. Plans from 5 patients who had undergone IMRT for primary tumors of the head and neck were used for planning proton therapy. Both sets of plans were prepared using computed tomography (Cl') scans with the goals of achieving 100% of the prescribed dose to the clinical target volume (CTV) and 95% to the planning TV (PTV) while maximizing cohformity to the PTV. Dose-volume histograms were generated and compared, as were conformity indexes (Cls) to the PTVs and mean doses to the organs at risk (OARs). Both modalities in all cases achieved 100% of the dose to the CTV and 95% to the PTV. Medd PTV CIs were coMparable (0.371 WIRT, 0.374 proton; p = 0.953). Mean doses were significantly lower In the proton plans to the contralateral submandibular (638.7 cGy IMRT, 4.3 cGy protons, /3 = 0.002) and parotid (533.3 cGy IMRT, 48.5 cGy protons, p = 0.003) glands; oral cavity (1760.4 cGy IMRT, 458.9 cGy protons, p = 0.003); spinal cord (2112.4 cGy IMRT, 249.2 cGy Protons, p = 0.002); and brainStem (1553.5/ cGy IMRT, 166.2 cGy protons, p = 0.005). Proton plans also produced lower maximum doses to the spinal cdrd (3692.1 cGy IMRT, 2014.8 cGy protons, p = 0.034) and brainstem (3412.1 cGy IMRT, 1387.6 cGy protons, p -= 0.00). Normal tissue V-10, V-30, and V-50 values were also significantly lower in the proton plans. We conclude that spot-scanning proton therapy can significantly reduce the integral dose to head and neck critical structures. Prospective studies are underway to determine if this reduced dose translates to improved quality of life. (C) 2013 American Association of Medical Dosimetrists.
引用
收藏
页码:390 / 394
页数:5
相关论文
共 50 条
  • [21] Comparison of intensity-modulated radiotherapy, adaptive radiotherapy proton radiotherapy, and adaptive proton radiotherapy for treatment of locally advanced head and neck cancer
    Simone, Charles B., II
    Ly, David
    Dan, Tu D.
    Ondos, John
    Ning, Holly
    Belard, Arnaud
    O'Connell, John
    Miller, Robert W.
    Simone, Nicole L.
    RADIOTHERAPY AND ONCOLOGY, 2011, 101 (03) : 376 - 382
  • [22] Intensity-modulated radiation therapy (IMRT): Toward a new standard for radiation therapy of head and neck cancer?
    Daly-Schveitzer, N.
    Julieron, M.
    Tao, Y. Gan
    Moussier, A.
    Bourhis, J.
    EUROPEAN ANNALS OF OTORHINOLARYNGOLOGY-HEAD AND NECK DISEASES, 2011, 128 (05) : 241 - 247
  • [23] An comparison of acute toxicities and patient-reported outcomes between intensity-modulated proton therapy and volumetric-modulated arc therapy after ipsilateral radiation for head and neck cancers
    Jeans, Elizabeth B.
    Shiraishi, Satomi
    Manzar, Gohar
    Morris, Lindsay K.
    Amundson, Adam
    McGee, Lisa A.
    Rwigema, Jean-Claude
    Neben-Wittich, Michelle
    Routman, David M.
    Ma, Daniel J.
    Patel, Samir H.
    Foote, Robert L.
    Lester, Scott C.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2022, 44 (02): : 359 - 371
  • [24] Effects of full-neck volumetric-modulated arc therapy vs split-field intensity-modulated head and neck radiation therapy on low neck targets and structures
    Anamalayil, Shibu J.
    Teo, Boon-Keng K.
    Lin, Alexander
    Lustig, Robert A.
    Ahn, Peter H.
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1062)
  • [25] Dental management in head and neck cancers: from intensity-modulated radiotherapy with photons to proton therapy
    Falek, Sabah
    Regmi, Rajesh
    Herault, Joel
    Dore, Melanie
    Vela, Anthony
    Dutheil, Pauline
    Moignier, Cyril
    Marcy, Pierre-Yves
    Drouet, Julien
    Beddok, Arnaud
    Letwin, Noah E.
    Epstein, Joel
    Parvathaneni, Upendra
    Thariat, Juliette
    SUPPORTIVE CARE IN CANCER, 2022, 30 (10) : 8377 - 8389
  • [26] Vestibular disorders and nausea during head and neck intensity-modulated radiation therapy
    Berta, E.
    Righini, C. A.
    Chamorey, E.
    Villa, J.
    Atallah, I.
    Reyt, E.
    Coffre, A.
    Schmerber, S.
    CANCER RADIOTHERAPIE, 2016, 20 (04): : 255 - 260
  • [27] Treatment Planning Comparison for Carbon Ion Radiotherapy, Proton Therapy and Intensity-modulated Radiotherapy for Spinal Sarcoma
    Matsumoto, Keiji
    Nakamura, Katsumasa
    Shioyama, Yoshiyuki
    Sasaki, Tomonari
    Ohga, Saiji
    Yamaguchi, Toshihiro
    Yoshitake, Tadamasa
    Asai, Kaori
    Kakiuchi, Genyu
    Honda, Hiroshi
    ANTICANCER RESEARCH, 2015, 35 (07) : 4083 - 4089
  • [28] Comparison of intensity-modulated radiation therapy (IMRT), 3D conformal proton therapy and intensity-modulated proton therapy (IMPT) for the treatment of metastatic brain cancer
    Sullivan, Matthew
    Jin, Hosang
    Ahmad, Salahuddin
    MEDICAL DOSIMETRY, 2023, 48 (02) : 73 - 76
  • [29] Effectiveness of robust optimization in intensity-modulated proton therapy planning for head and neck cancers
    Liu, Wei
    Frank, Steven J.
    Li, Xiaoqiang
    Li, Yupeng
    Park, Peter C.
    Dong, Lei
    Zhu, X. Ronald
    Mohan, Radhe
    MEDICAL PHYSICS, 2013, 40 (05)
  • [30] Quality assurance of intensity modulated radiation therapy treatment planning using head and neck phantom
    Zahra
    Rehman, Jalil ur
    Asghar, H. M. Noor ul Huda Khan
    Ahmad, Nisar
    Gilani, Zaheer Abbas
    Nasar, Gulfam
    Akhter, Malik M.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 239 - 245