Long-term effects of different humidification systems on endotracheal tube patency - Evaluation by the acoustic reflection method

被引:56
作者
Jaber, S [1 ]
Pigeot, J [1 ]
Fodil, R [1 ]
Maggiore, S [1 ]
Harf, A [1 ]
Isabey, D [1 ]
Brochard, L [1 ]
Louis, B [1 ]
机构
[1] Univ Paris 12, Serv Reanimat Med, Hop Henri Mondor, Assistance Publ Hop Paris, F-94000 Creteil, France
关键词
D O I
10.1097/00000542-200404000-00006
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Accumulation of mucous secretions in an endotracheal tube (ETT) increases its resistance, and the amount of deposit may be affected by the quality of humidification and heating of the inspired gas. Methods: The authors assessed the impact of two humidification systems, a heated humidifier (HH) and a hygroscopic-hydrophobic heat and moisture exchanger (HME), on the ETT patency in patients selected to require mechanical ventilation for more than 48 h. This comparison was performed over two consecutive periods and used the acoustic reflection method, which characterizes the amount and site of ETT obstruction and allows estimating ETT inner volume and resistance. Measurements were performed three times a week over the period of mechanical ventilation. Comparisons were performed at mid duration and at the end of the mechanical ventilation period. Results: The HH was used in 34 patients, and the HME was used in 26 patients. The two groups had similar severity and duration of mechanical ventilation. At mid duration of mechanical ventilation (5.5 +/- 3.3 vs. 4.8 +/- 3.3 days; P = 0.4), no difference was observed in ETT volume and resistance between the two groups. At the end of the study period (10.5 +/- 5.8 vs. 9.6 +/- 6.3 days of mechanical ventilation; P = 0.4), ETT volume was reduced to a greater extent with HME than with HH (-3.3 +/- 2.9 vs. -5.1 +/- 2.5%; P = 0.008), and ETT resistance increased significantly more with the HME than with the HH (8.4 +/- 12.2 vs. 19.4 +/- 17.7%; P = 0.001). Conclusion: Prolonged use of humidification systems results in progressive reduction of ETT patency, and to a greater extent with HMEs than with Hills.
引用
收藏
页码:782 / 788
页数:7
相关论文
共 36 条
[1]   A comparison of observational studies and randomized, controlled trials. [J].
Benson, K ;
Hartz, AJ .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 342 (25) :1878-1886
[2]  
Campbell R S, 2000, Respir Care, V45, P306
[3]   HUMIDITY AND THE ANESTHETIZED PATIENT [J].
CHALON, J ;
PATEL, C ;
ALI, M ;
RAMANATHAN, S ;
CAPAN, L ;
TANG, CK ;
TURNDORF, H .
ANESTHESIOLOGY, 1979, 50 (03) :195-198
[4]   ENDOTRACHEAL-TUBE OCCLUSION ASSOCIATED WITH THE USE OF HEAT AND MOISTURE EXCHANGERS IN THE INTENSIVE-CARE UNIT [J].
COHEN, IL ;
WEINBERG, PF ;
FEIN, IA ;
ROWINSKI, GS .
CRITICAL CARE MEDICINE, 1988, 16 (03) :277-279
[5]   Prolonged use of heat and moisture exchangers does not affect device efficiency or frequency rate of nosocomial pneumonia [J].
Davis, K ;
Evans, SL ;
Campbell, RS ;
Johannigman, JA ;
Luchette, FA ;
Porembka, DT ;
Branson, RD .
CRITICAL CARE MEDICINE, 2000, 28 (05) :1412-1418
[6]   Changes in the work of breathing induced by tracheotomy in ventilator-dependent patients [J].
Diehl, JL ;
El Atrous, S ;
Touchard, D ;
Lemaire, F ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (02) :383-388
[7]  
DREYFUSS D, 1995, AM J RESP CRIT CARE, V151, P986
[8]   TEMPERATURE, HUMIDITY AND MUCUS FLOW IN INTUBATED TRACHEA [J].
FORBES, AR .
BRITISH JOURNAL OF ANAESTHESIA, 1974, 46 (01) :29-34
[9]   Detection of endotracheal tube obstruction by analysis of the expiratory flow signal [J].
Guttmann, J ;
Eberhard, L ;
Haberthür, C ;
Mols, G ;
Kessler, V ;
Lichtwarck-Aschoff, M ;
Geiger, K .
INTENSIVE CARE MEDICINE, 1998, 24 (11) :1163-1172
[10]   Noninvasive estimate of work of breathing due to the endotracheal tube [J].
Heyer, L ;
Louis, B ;
Isabey, D ;
Lofaso, F ;
Brochard, L ;
Fredberg, JJ ;
Harf, A .
ANESTHESIOLOGY, 1996, 85 (06) :1324-1333