Wearing the F-Scan mobile in-shoe pressure measurement system alters gait characteristics during running

被引:22
作者
Kong, Pui W. [1 ]
De Heer, Hendrik [2 ]
机构
[1] Univ Texas El Paso, Dept Kinesiol, El Paso, TX 79902 USA
[2] Univ Texas El Paso, Dept Psychol, El Paso, TX 79968 USA
关键词
Stride length; Stride frequency; Stance time; Biomechanics; PLANTAR PRESSURE; WALKING; FOOT; RESPONSES;
D O I
10.1016/j.gaitpost.2008.05.018
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This study investigated the influence of wearing an F-Scan mobile in-shoe pressure measurement system on running characteristics. Six subjects ran on a treadmill at three speeds (3.5 m s(-1), 4.5 m s(-1) and 5.4 m s(-1)) with and without wearing the F-Scan system while kinematic data were collected at 240 Hz using a motion capture system. Six gait cycles were selected for analysis, with touchdown and toe-off Visually identified based on foot markets displacement. Spatio-temporal gait parameters including stride frequency, stride length, stride length relative to height, and stance time were determined. A 2 x 3 ANOVA with repeated measures (alpha = 0.05) was performed to identify differences in each gait parameter between running with and without the F-Scan system at different speeds. Wearing the F-Scan system did not affect the stance time but lead to an increase in stride frequency (P < 0.05) and a decrease in stride length (P < 0.05) and relative stride length (P < 0.05). As speed increased, stance time decreased while stride frequency, stride length and relative stride length increased (all P < 0.001). These results imply that wearing the F-Scan system alters gait characteristics and therefore data obtained may not represent those in a real life setting, at least in the case of running. One should take into account the potential risk of the movement of interest being altered when interpreting data obtained while subjects were wearing the F-Scan system. Future instrumentation should minimize the potential influence a measurement device may have on natural movement. Published by Elsevier B.V.
引用
收藏
页码:143 / 145
页数:3
相关论文
共 18 条
[1]   A comparison of vertical force and temporal parameters produced by an in-shoe pressure measuring system and a force platform (vol 15, pg 781, 2000) [J].
Barnett, S ;
Cunningham, JL ;
West, SE .
CLINICAL BIOMECHANICS, 2001, 16 (04) :351-+
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BURKETT LN, 1985, MED SCI SPORT EXER, V17, P158
[4]   Effect of sock on biomechanical responses of foot during walking [J].
Dai, XQ ;
Li, Y ;
Zhang, M ;
Cheung, JTM .
CLINICAL BIOMECHANICS, 2006, 21 (03) :314-321
[5]   Barefoot-shod running differences: Shoe or mass effect? [J].
Divert, C. ;
Mornieux, G. ;
Freychat, P. ;
Baly, L. ;
Mayer, F. ;
Belli, A. .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2008, 29 (06) :512-518
[6]   Walking and running plantar pressure analysis before and after resection of tarsal coalition [J].
Hetsroni, Iftach ;
Ayalon, Moshe ;
Mann, Gideon ;
Meyer, Ganit ;
Nyska, Meir .
FOOT & ANKLE INTERNATIONAL, 2007, 28 (05) :575-580
[7]   Gait and posture responses to backpack load during level walking in children [J].
Hong, YL ;
Cheung, CK .
GAIT & POSTURE, 2003, 17 (01) :28-33
[8]   Accuracy and precision of two in-shoe pressure measurement systems [J].
Hsiao, HW ;
Guan, JH ;
Weatherly, M .
ERGONOMICS, 2002, 45 (08) :537-555
[9]   THE ENERGY-COST OF WOMEN WALKING AND RUNNING IN SHOES AND BOOTS [J].
JONES, BH ;
KNAPIK, JJ ;
DANIELS, WL ;
TONER, MM .
ERGONOMICS, 1986, 29 (03) :439-443
[10]   Reliability and running speed effects of in-shoe loading measurements during slow treadmill running [J].
Kernozek, TW ;
Zimmer, KA .
FOOT & ANKLE INTERNATIONAL, 2000, 21 (09) :749-752