Predicting metabolic rate during level and uphill outdoor walking using a low-cost GPS receiver

被引:5
作者
de Mullenheim, Pierre-Yves [1 ]
Dumond, Remy [1 ]
Gernigon, Marie [2 ,3 ]
Mahe, Guillaume [4 ,5 ,9 ]
Lavenu, Audrey [4 ,6 ]
Bickert, Sandrine [2 ]
Prioux, Jacques [1 ,7 ]
Noury-Desvaux, Benedicte [2 ,3 ,8 ]
Le Faucheur, Alexis [1 ,4 ,7 ]
机构
[1] Univ Rennes 2, Fac Sport Sci, EA 1274, Movement Sport & Hlth Lab, Rennes, France
[2] Univ Hosp, Lab Vasc Invest & Sports Med, Angers, France
[3] Univ Angers, INSERM, CNRS, UMR 1083,Med Sch,Lab Physiol, Angers, France
[4] INSERM, CIC 1414, Clin Invest Ctr, Rennes, France
[5] Univ Hosp, Heart Vessels Imaging Team, Rennes, France
[6] Univ Rennes 1, Sch Med, Lab Expt & Clin Pharmacol, Rennes, France
[7] Ecole Normale Super Rennes, Dept Sport Sci & Phys Educ, Campus Ker Lann, F-35170 Bruz, France
[8] Univ Catholique Ouest, Inst Phys Educ & Sports Sci IFEPSA, Les Ponts De Ce, France
[9] Univ Rennes 1, Rennes, France
关键词
wearable activity monitors; energy expenditure; equations; global positioning system; grade; GLOBAL POSITIONING SYSTEM; ENERGY-EXPENDITURE; PHYSICAL-ACTIVITY; HEART-RATE; ACCELEROMETRY; MORTALITY; EXERCISE; ADULTS; SPEED; EPIDEMIOLOGY;
D O I
10.1152/japplphysiol.00224.2016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The objective of this study was to assess the accuracy of using speed and grade data obtained from a low-cost global positioning system (GPS) receiver to estimate metabolic rate (MR) during level and uphill outdoor walking. Thirty young, healthy adults performed randomized outdoor walking for 6-min periods at 2.0, 3.5, and 5.0 km/h and on three different grades: 1) level walking, 2) uphill walking on a 3.7% mean grade, and 3) uphill walking on a 10.8% mean grade. The reference MR [metabolic equivalents (METs) and oxygen uptake (VO2)]values were obtained using a portable metabolic system. The speed and grade were obtained using a low-cost GPS receiver (1-Hz recording). The GPS grade (Delta altitude/distance walked) was calculated using both uncorrected GPS altitude data and GPS altitude data corrected with map projection software. The accuracy of predictions using reference speed and grade (actual([SPEED/GRADE])) data was high [R-2 = 0.85, root-mean-square error (RMSE) = 0.68 MET]. The accuracy decreased when GPS speed and uncorrected grade (GPS([UNCORRECTED])) data were used, although it remained substantial (R-2 = 0.66, RMSE = 1.00 MET). The accuracy was greatly improved when the GPS speed and corrected grade (GPS([CORRECTED])) data were used (R-2 = 0.82, RMSE = 0.79 MET). Published predictive equations for walking MR were also cross-validated using actual or GPS speed and grade data when appropriate. The prediction accuracy was very close when either actual([SPEED/GRADE]) values or GPS([CORRECTED]) values (for level and uphill combined) or GPS speed values (for level walking only) were used. These results offer promising research and clinical applications related to the assessment of energy expenditure during free-living walking.
引用
收藏
页码:577 / 588
页数:12
相关论文
共 53 条
  • [21] PREDICTING METABOLIC ENERGY COST
    GIVONI, B
    GOLDMAN, RF
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1971, 30 (03) : 429 - &
  • [22] Effects of walking on mortality among nonsmoking retired men
    Hakim, AA
    Petrovitch, H
    Burchfiel, CM
    Ross, GW
    Rodriguez, BL
    White, LR
    Yano, K
    Curb, JD
    Abbott, RD
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 338 (02) : 94 - 99
  • [23] METs and Accelerometry of Walking in Older Adults: Standard versus Measured Energy Cost
    Hall, Katherine S.
    Howe, Cheryl A.
    Rana, Sharon R.
    Martin, Clara L.
    Morey, Miriam C.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (03) : 574 - 582
  • [24] Haskell WL, 2007, MED SCI SPORT EXER, V39, P1423, DOI [10.1249/mss.0b013e3180616b27, 10.1161/CIRCULATIONAHA.107.185649]
  • [25] GLOBAL POSITIONING SYSTEM WATCHES FOR ESTIMATING ENERGY EXPENDITURE
    Hongu, Nobuko
    Orr, Barron J.
    Roe, Denise J.
    Reed, Rebecca G.
    Going, Scott B.
    [J]. JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2013, 27 (11) : 3216 - 3220
  • [26] Hopkins W., 2006, A new view of statistics
  • [27] Stability of the K4b2 portable metabolic analyser during rest, walking and running
    Howe, Christopher C. F.
    Matzko, Richard O.
    Piaser, Fabio
    Pitsiladis, Yannis P.
    Easton, Chris
    [J]. JOURNAL OF SPORTS SCIENCES, 2014, 32 (02) : 157 - 163
  • [28] A Framework for Using GPS Data in Physical Activity and Sedentary Behavior Studies
    Jankowska, Marta M.
    Schipperijn, Jasper
    Kerr, Jacqueline
    [J]. EXERCISE AND SPORT SCIENCES REVIEWS, 2015, 43 (01): : 48 - 56
  • [29] Study of human outdoor walking with a low-cost GPS and simple spreadsheet analysis
    Le Faucheur, Alexis
    Abraham, Pierre
    Jaquinandi, Vincent
    Bouye, Philippe
    Saumet, Jean Louis
    Noury-Desvaux, Benedicte
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (09) : 1570 - 1578
  • [30] Leger L, 1980, Can J Appl Sport Sci, V5, P77