Sensitive colorimetric sensor for point-of-care detection of acetylcholinesterase using cobalt oxyhydroxide nanoflakes

被引:57
作者
Jin, Rui [1 ]
Xing, Zihao [2 ]
Kong, Deshuai [1 ]
Yan, Xu [1 ]
Liu, Fangmeng [1 ]
Gao, Yuan [1 ]
Sun, Peng [1 ]
Liang, Xishuang [1 ]
Lu, Geyu [1 ]
机构
[1] Jilin Univ, Coll Elect Sci & Engn, Jilin Key Lab Adv Gas Sensor, State Key Lab Integrated Optoelect, Changchun 130012, Jilin, Peoples R China
[2] Jilin Univ, Coll Chem, State Key Lab Inorgan Synth & Preparat Chem, Changchun 130012, Jilin, Peoples R China
关键词
PEROXIDASE CATALYTIC-ACTIVITY; ENZYME; BIOSENSOR; NANOSHEETS; MIMICKING; PESTICIDE; NANOTUBES; DESIGN; ASSAY;
D O I
10.1039/c8tb02987c
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Point-of-care monitoring of acetylcholinesterase (AChE) is of significant importance for pesticide poisoning and disease diagnosis because it plays a pivotal role in biological nerve conduction systems. Herein, we designed a colorimetric strategy for the facile and accurate detection of AChE based on tandem catalysis with a multi-enzyme system, which is constituted by cobalt oxyhydroxide nanoflakes (CoOOH NFs) and choline oxidase (CHO). In this sensor, AChE catalytically hydrolyzed acetylcholine (ACh) to produce choline, which was further efficiently oxidized by CHO to yield H2O2. CoOOH NFs, as a nanozyme, efficiently catalyzed 3,3',5,5'-tetramethylbenzidine (TMB) into blue oxTMB with the help of H2O2, accompanied by an enhancement of absorbance intensity. The resulting intensity could be employed as the signal output of the CHO/CoOOH/ACh system in monitoring AChE. Under optimal conditions, the developed sensor possessed a sensitive response to AChE with a detection limit of 33 mu U mL(-1). Interestingly, the proposed platform was applied to fabricate a paper-based sensor for rapidly recognizing AChE by direct observation with the naked eyes. Combined with a smartphone and ImageJ software, we further developed an image-processing algorithm for the quantitative detection of AChE with highly promising results, which validated the outstanding potential of on-site application in clinical diagnostics and pesticide poisoning.
引用
收藏
页码:1230 / 1237
页数:8
相关论文
共 50 条
  • [41] A Rapid Label-Free Disposable Electrochemical Salivary Point-of-Care Sensor for SARS-CoV-2 Detection and Quantification
    Farsaeivahid, Nadia
    Grenier, Christian
    Nazarian, Sheyda
    Wang, Ming L. L.
    SENSORS, 2023, 23 (01)
  • [42] Enzymatic Behavior Regulation-Based Colorimetric and Electrochemiluminescence Sensing of Phosphate Using the Cobalt Oxyhydroxide Nanosheet
    Cheng, Hong
    Hui, Pansen
    Peng, Jiaxin
    Li, Wei
    Ma, Wenjie
    Wang, Huizhen
    Huang, Jin
    He, Xiaoxiao
    Wang, Kemin
    ANALYTICAL CHEMISTRY, 2021, 93 (17) : 6770 - 6778
  • [43] Smartphone-assisted point-of-care colorimetric biosensor for the detection of urea via pH-mediated AgNPs growth
    Choi, Cheol-Kyun
    Shaban, Samy M.
    Moon, Byeong-Seok
    Pyun, Do-Gi
    Kim, Dong-Hwan
    ANALYTICA CHIMICA ACTA, 2021, 1170
  • [44] Creation of a point-of-care therapeutics sensor using protein engineering, electrochemical sensing and electronic integration
    Cai, Rong
    Ngwadom, Chiagoziem
    Saxena, Ravindra
    Soman, Jayashree
    Bruggeman, Chase
    Hickey, David P.
    Verduzco, Rafael
    Ajo-Franklin, Caroline M.
    NATURE COMMUNICATIONS, 2024, 15 (01)
  • [45] Detection of mpox and other orthopoxviruses using a lateral flow device as a point-of-care diagnostic
    Laidlaw, Stephen M.
    Ulaeto, David
    Lonsdale, Steve
    Clark, Graeme
    Sumner, Rebecca
    Edwards, Thomas
    Adams, Emily
    Logist, Anne-Sophie
    Van Holm, Bram
    de Motes, Carlos Maluquer
    Horby, Peter
    Maes, Piet
    Carroll, Miles W.
    MICROBIOLOGY SPECTRUM, 2025,
  • [46] A cobalt oxyhydroxide nanoflake-based nanoprobe for the sensitive fluorescence detection of T4 polynucleotide kinase activity and inhibition
    Cen, Yao
    Yang, Yuan
    Yu, Ru-Qin
    Chen, Ting-Ting
    Chu, Xia
    NANOSCALE, 2016, 8 (15) : 8202 - 8209
  • [47] On-site sensing of pesticides using point-of-care biosensors: a review
    Kalyani, Neeti
    Goel, Surbhi
    Jaiswal, Swati
    ENVIRONMENTAL CHEMISTRY LETTERS, 2021, 19 (01) : 345 - 354
  • [48] Advances in Paper-based Colorimetric Sensors Based on Nanozymes for Point-of-Care Testing
    Zhou, Shuang
    Mei, Xuena
    Wang, Shaowe
    Yang, Hongmei
    Yu, Jinghua
    Zhang, Yan
    ACTA CHIMICA SINICA, 2025, 83 (02) : 170 - 183
  • [49] A Colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) Detection Platform for a Point-of-Care Dengue Detection System on a Lab-on-Compact-Disc
    Thiha, Aung
    Ibrahim, Fatimah
    SENSORS, 2015, 15 (05) : 11431 - 11441
  • [50] Acetylcholinesterase Inhibitors Assay Using Colorimetric pH Sensitive Strips and Image Analysis by a Smartphone
    Kostelnik, Adam
    Cegan, Alexander
    Pohanka, Miroslav
    INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 2017