Inverse plan optimization accounting for random geometric uncertainties with a multiple instance geometry approximation (MIGA)

被引:44
作者
McShan, D. L. [1 ]
Kessler, M. L. [1 ]
Vineberg, K. [1 ]
Fraass, B. A. [1 ]
机构
[1] Univ Michigan, Dept Radiat Oncol, Ann Arbor, MI 48109 USA
关键词
treatment planning; optimization; geometrical uncertainty;
D O I
10.1118/1.2191016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Radiotherapy treatment plans that are optimized to be highly conformal based on a static patient geometry can be degraded by setup errors and/or intratreatment motion, particularly for IMRT plans. To achieve improved plans in the face of geometrical uncertainties, direct simulation of multiple instances of the patient anatomy (to account for setup and/or motion uncertainties) is used within the inverse planning process. This multiple instance geometry approximation (MIGA) method uses two or more instances of the patient anatomy and optimizes a single beam arrangement for all instances concurrently. Each anatomical instance can represent expected extremes or a weighted distribution of geometries. The current implementation supports mapping between instances that include distortions, but this report is limited to the use of rigid body translations/rotations. For inverse planning, the method uses beamlet dose calculations for each instance, with the resulting doses combined using a weighted sum of the results for the multiple instances. Beamlet intensities are then optimized using the inverse planning system based on the cost for the composite dose distribution. MIGA can simulate various types of geometrical uncertainties, including random setup error and intratreatment motion. A limited number of instances are necessary to simulate Gaussian-distributed errors. IMRT plans optimized using MIGA show significantly less degradation in the face of geometrical errors, and are robust to the expected (simulated) motions. Results for a complex head/neck plan involving multiple target volumes and numerous normal structures are significantly improved when the MIGA method of inverse planning is used. Inverse planning using MIGA can lead to significant improvements over the use of simple PTV volume expansions for inclusion of geometrical uncertainties into inverse planning, since it can account for the correlated motions of the entire anatomical representation. The optimized plan results reflect the differing patient geometry situations which can be important near the surface or heterogeneities. For certain clinical situations, the MIGA optimization approach can correct for a significant part of the degradation of the plan caused by the setup uncertainties. (c) 2006 American Association of Physicists in Medicine.
引用
收藏
页码:1510 / 1521
页数:12
相关论文
共 58 条
[11]   A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study [J].
Chetty, IJ ;
Rosu, M ;
Tyagi, N ;
Marsh, LH ;
McShan, DL ;
Balter, JM ;
Fraass, BA ;
Ten Haken, RK .
MEDICAL PHYSICS, 2003, 30 (07) :1776-1780
[12]   The effects of intra-fraction organ motion on the delivery of intensity-modulated field with a multileaf collimator [J].
Chui, CS ;
Yorke, E ;
Hong, L .
MEDICAL PHYSICS, 2003, 30 (07) :1736-1746
[13]   SPINAL-CORD PROTECTION DURING RADIATION-THERAPY [J].
COIA, L ;
CHU, J ;
LARSEN, R ;
MYERSON, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (09) :1697-1705
[14]   The impact of geometric uncertainty on hypofractionated external beam radiation therapy of prostate cancer [J].
Craig, T ;
Moiseenko, V ;
Battista, J ;
Van Dyk, J .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03) :833-842
[15]   Limitations of a convolution method for modeling geometric uncertainties in radiation therapy. II. The effect of a finite number of fractions [J].
Craig, T ;
Battista, J ;
Van Dyk, J .
MEDICAL PHYSICS, 2003, 30 (08) :2012-2020
[16]  
DOSS LL, 1979, P WORKSHOP QUALITY C, P57
[17]   PRESCRIPTION, PRECISION, AND DECISION IN TREATMENT PLANNING - KEYNOTE ADDRESS [J].
DUTREIX, A .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1987, 13 (09) :1291-1296
[18]   Salivary gland sparing and improved target irradiation by conformal and intensity modulated irradiation of head and neck cancer [J].
Eisbruch, A ;
Ship, JA ;
Dawson, LA ;
Kim, HM ;
Bradford, CR ;
Terrell, JE ;
Chepeha, DB ;
Teknos, TN ;
Hogikyan, ND ;
Anzai, Y ;
Marsh, LH ;
Ten Haken, RK ;
Wolf, GT .
WORLD JOURNAL OF SURGERY, 2003, 27 (07) :832-837
[19]  
Eisbruch Avraham, 2002, Med Dosim, V27, P99, DOI 10.1016/S0958-3947(02)00091-2
[20]  
Fraass B, 2000, USE OF COMPUTERS IN RADIATION THERAPY, P32