Quench protection design of a 9.4 T whole-body MRI superconducting magnet

被引:5
作者
Chen, Shunzhong [1 ]
Li, Yi [1 ]
Dai, Yinming [1 ]
Lei, Yuanzhong [1 ]
Yan, Luguang [1 ]
机构
[1] Chinese Acad Sci, Inst Elect Engn, Key Lab Appl Superconduct, Beijing 100190, Peoples R China
来源
PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS | 2014年 / 497卷
关键词
MRI; Quench; Protection; Heater;
D O I
10.1016/j.physc.2013.11.001
中图分类号
O59 [应用物理学];
学科分类号
摘要
A 9.4 T MRI superconducting magnet with a 800 mm clear warm bore in diameter is designed and fabricated for bioscience research. The superconducting magnet consisting of five coaxial solenoid coils is fabricated with NbTi Wire-in-Channel (WIC) conductor where the ratios of copper to non-copper are from 5 to 10. The four compensation solenoid coils are with rectangular NbTi/Cu strand wires. The magnet will be operated in a relative low nominal current of 224.5 A with a high level of stored energy, about 138 MJ. A protection method with the cold diodes and resistors in series across the subdivided sections and active trigger heater to accelerate quench is adopted to avoid the damage of the magnet. In the paper, the quench simulation results of currents, voltages and hot-spot temperatures based on the protection scheme are analyzed in details. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 53
页数:5
相关论文
共 50 条
[41]   Emerging techniques: Whole-body screening and staging with MRI [J].
Lauenstein, Thomas C. ;
Semelka, Richard C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (03) :489-498
[42]   Cognitive effects of head-movements in stray fields generated by a 7 Tesla whole-body MRI magnet [J].
de Vocht, F. ;
Stevens, T. ;
Glover, P. ;
Sunderland, A. ;
Gowland, P. ;
Kromhout, H. .
BIOELECTROMAGNETICS, 2007, 28 (04) :247-255
[43]   Design, Fabrication and Measurement of a 3 T Cryogen-Free Animal MRI Superconducting Magnet [J].
Wang, Yaohui ;
Liu, Hui ;
Chen, Shunzhong ;
Wang, Weimin ;
Liu, Feng ;
Wang, Qiuliang .
IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2024, 34 (05) :1-4
[44]   Whole-body T2* mapping at 1.5 T [J].
Rossi, Cristina ;
Boss, Andreas ;
Haap, Michael ;
Martirosian, Petros ;
Claussen, Claus D. ;
Schick, Fritz .
MAGNETIC RESONANCE IMAGING, 2009, 27 (04) :489-496
[45]   Principles of whole-body continuously-moving-table MRI [J].
Boernert, Peter ;
Aldefeld, Bernd .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :1-12
[46]   Morris, Peter: Whole-body MRI in Nottingham: The First Steps [J].
Morris, Peter .
EMAGRES, 2012, 1 (01) :5-10
[47]   Sensitivity and Specificity of Whole-body MRI for the Detection of Pediatric Malignancy [J].
Cochran, Thomas ;
Patel, Sachit ;
Kruse, Travis ;
Lyden, Elizabeth ;
Comer, Susan ;
Ford, James .
JOURNAL OF PEDIATRIC HEMATOLOGY ONCOLOGY, 2023, 45 (01) :E26-E30
[48]   Whole-body MRI in children: Current status and future applications [J].
Darge, Kassa ;
Jaramillo, Diego ;
Siegel, Marilyn J. .
EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (02) :289-298
[49]   Ultra-high field magnets for whole-body MRI [J].
Warner, Rory .
SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2016, 29 (09)
[50]   Optimal Design for Open MRI Superconducting Magnet with Active Shielding [J].
王春忠 ;
王秋良 ;
李兰凯 ;
荣明 ;
周又元 .
Journal of Measurement Science and Instrumentation, 2010, (02) :178-182