Bioartificial liver support for acute liver failure.: First case treated in Spain

被引:0
作者
Salmerón, JM
Lozano, M
Agustí, E
Mas, A
Mazzara, R
Marín, P
Ordinas, A
Rodés, J
机构
[1] Univ Barcelona, Inst Invest Biomed August Pi Sunyer, Hosp Clin Barcelona, Serv Hemoterapia & Hemostasia,Area Aferesis, E-08007 Barcelona, Spain
[2] Univ Barcelona, Inst Invest Biomed August Pi Sunyer, Hosp Clin Barcelona, Serv Hemoterapia & Hemostasia,Lab Criopreservac, E-08007 Barcelona, Spain
来源
MEDICINA CLINICA | 2001年 / 117卷 / 20期
关键词
bioartificial liver; hepatic failure; acute hepatitis;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Research aimed at developing artificial liver support systems has experienced a notable increase in the last decade. Hybrid systems including bioreactors containing hepatocytes which are perfused by liver failure patients blood or plasma have been deviced for the first time. The purpose of such a strategy is to substitute, at least in part, the impaired hepatic function thus improving the prognosis of patients with severe acute or chronic liver diseases. CASE REPORT: In the present paper, we report the first such a case treated in Spain in the context of a controlled, randomized, multicenter international study aimed at investigating the usefulness and safety of a bioartificial liver support system based on cryopreserved porcine hepatocytes in patients with acute liver failure or having a non-functioning primary graft after liver transplantation. RESULTS: In this first experience, two sessions of treatment could be completed before a patient with acute liver failure underwent a successful emergency liver transplantation. After more than or or two years of follow-up, the patient is in her normal life activities and she has not presented any adverse event related to the bioartificial liver support therapy so far. CONCLUSION: Bioartificial liver support systems are starting to be available for use in clinical practice. Yet it is mandatory to establish their safety and efficacy before a widespread recommendation.
引用
收藏
页码:781 / 784
页数:4
相关论文
共 29 条
[1]   Xenoantibody response of patients with severe acute liver failure exposed to porcine antigens following treatment with a bioartificial liver [J].
Baquerizo, A ;
Mhoyan, A ;
Shirwan, H ;
Swensson, J ;
Busuttil, RW ;
Demetriou, AA ;
Cramer, DV .
TRANSPLANTATION PROCEEDINGS, 1997, 29 (1-2) :964-965
[2]   CLASSIFYING ACUTE LIVER-FAILURE [J].
BERNUAU, J ;
BENHAMOU, JP .
LANCET, 1993, 342 (8866) :252-253
[3]   ORTHOTOPIC LIVER-TRANSPLANTATION IN FULMINANT AND SUBFULMINANT HEPATITIS - THE PAUL-BROUSSE EXPERIENCE [J].
BISMUTH, H ;
SAMUEL, D ;
CASTAING, D ;
ADAM, R ;
SALIBA, F ;
JOHANN, M ;
AZOULAY, D ;
DUCOT, B ;
CHICHE, L .
ANNALS OF SURGERY, 1995, 222 (02) :109-119
[4]   EMERGENCY LIVER-TRANSPLANTATION FOR FULMINANT-HEPATITIS [J].
BISMUTH, H ;
SAMUEL, D ;
GUGENHEIM, J ;
CASTAING, D ;
BERNUAU, J ;
RUEFF, B ;
BENHAMOU, JP .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (03) :337-341
[5]   Consideration of potential immunological problems in the application of xenogenic hybrid liver support [J].
Bornemann, R ;
Smith, MD ;
Gerlach, JC .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (11) :655-663
[6]   LIVER-TRANSPLANTATION FOR ACUTE LIVER-FAILURE - ANALYSIS OF APPLICABILITY [J].
CASTELLS, A ;
SALMERON, JM ;
NAVASA, M ;
RIMOLA, A ;
SALO, J ;
ANDREU, H ;
MAS, A ;
RODES, J .
GASTROENTEROLOGY, 1993, 105 (02) :532-538
[7]   Pilot-controlled trial of the extracorporeal liver assist device in acute liver failure [J].
Ellis, AJ ;
Hughes, RD ;
Wendon, JA ;
Dunne, J ;
Langley, PG ;
Kelly, JH ;
Gislason, GT ;
Sussman, NL ;
Williams, R .
HEPATOLOGY, 1996, 24 (06) :1446-1451
[8]  
GAZZARD BG, 1975, Q J MED, V44, P615
[9]   Development of a hybrid liver support system: A review [J].
Gerlach, JC .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1996, 19 (11) :645-654
[10]   LIVER-TRANSPLANTATION ACROSS ABO BLOOD-GROUP BARRIERS [J].
GUGENHEIM, J ;
SAMUEL, D ;
REYNES, M ;
BISMUTH, H .
LANCET, 1990, 336 (8714) :519-523