A High-Repetition-Rate Bounded-Wave EMP Simulator Based on Hydrogen Thyratron and Transmission Line Transformer

被引:2
作者
Feng, Deren [1 ]
Xu, Xiaojuan [1 ]
Luo, Jin [1 ]
Lee, Xiaolong [1 ]
Yao, Zhaohu [1 ]
Yu, Chengda [2 ]
机构
[1] Anhui Univ Technol, Maanshan 243032, Peoples R China
[2] Chinese Peoples Liberat Army 63961 Troops, Beijing 100012, Peoples R China
关键词
Bounded-wave simulator; hydrogen thyratron; impedance match; repetition rate; transmission line transformers (TLTs); VOLTAGE; DESIGN; POWER;
D O I
10.1109/TPS.2012.2222030
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
Transmission line transformers (TLTs) are usually used for impedance match and pulse transformers, which have received gradual attention due to their excellent frequency response characteristics over conventional wire-wound transformers. This transformer basically consists of equal lengths of transmission line normally used by coaxial cables connected in parallel at the input side of the transformer and in series at the output side so that the output voltage can be boosted in proportion. For high-voltage and high-current pulsed system, a gas spark switch is usually used because of its large state current and high hold-off voltage. However, it is hard to get high repetition rate with gas spark switch, because of recombination of the ionized gas. Owing to the high working voltage, high pulse current, quick and steady fire lighting, low trigger voltage, reliable triggering, long life, light weight, small size, and ease of use, hydrogen thyratron, which selected hydrogen or deuterium as arc discharge dielectric, is widely used in the fields of scientific research, military, medical treatment, industry, etc. In this paper, we propose a high-power pulsed system based on TLT and hydrogen thyratron. The system is likely to work at higher voltage as well as higher repetition rate than what are for a conventional system made of wire-wound transfer and gas spark switch.
引用
收藏
页码:3499 / 3507
页数:9
相关论文
共 20 条
[1]  
Allen R. J., 2005, 15th IEEE International Pulsed Power Conference, P318
[2]   Analysis and design procedure of transmission-line transformers [J].
Gomez-Jimenez, Pablo ;
Otero, Pablo ;
Marquez-Segura, Enrique .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (01) :163-171
[3]   A high-voltage transmission-line pulse transformer with very low droop [J].
Graneau, PN ;
Rossi, JO ;
Brown, MP ;
Smith, PW .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (07) :2630-2635
[4]  
Grossner N, 1983, TRANSFORMERS ELECT C, P467
[5]  
Guanella G, 1944, REV BROWN BOVERI, V31, P327
[6]   Fast-rise-time pulse transformers built from rotated stacked 1: 1 transformers [J].
Jain, K. K. ;
Smith, Paul W. .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2006, 34 (05) :1853-1857
[7]  
Luo C., 1994, HIGH VOLT ENG, V20, P77, DOI [10.13336/j.1003-6520.hve.1994.02.020, DOI 10.13336/J.1003-6520.HVE.1994.02.020]
[8]  
Malinen A, 2004, 2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 4, PROCEEDINGS, P413
[9]   A pulsed power supply based on power semiconductor switches and transmission line transformer [J].
Qiu, Jian ;
Liu, Kefu ;
Wu, Yifan .
IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2007, 14 (04) :927-930
[10]   HIGH-POWER, SHORT-PULSE GENERATORS BASED ON INDUCTION VOLTAGE ADDERS [J].
RAMIREZ, JJ ;
PRESTWICH, KR ;
SMITH, ID .
PROCEEDINGS OF THE IEEE, 1992, 80 (06) :946-957