18F-FDG production procedures as a source of eye lens exposure to radiation

被引:7
作者
Wrzesien, Malgorzata [1 ]
机构
[1] Univ Lodz, Fac Phys & Appl Informat, Dept Nucl Phys & Radiat Safety, Pomorska 149-153, PL-90236 Lodz, Poland
关键词
F-18-FDG; eye lens; exposure; production procedures; nuclear medicine; quality control; DOSE CONVERSION COEFFICIENTS; NUCLEAR-MEDICINE; WHOLE-BODY; PROTECTION; RADIOLOGY; DOSIMETRY; WORKERS; STAFF;
D O I
10.1088/1361-6498/aaa287
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Decreasing the individual dose limit of exposure to ionizing radiation to the eye lenses means verifying the need for routine monitoring of the eye lenses of workers exposed to ionizing radiation, including those employed in facilities producing radiopharmaceuticals based on short-lived isotopes. This work analyzes the exposure of the eye lenses of employees of centers that produce the isotopes for positron emission tomography, in particular fluorine-18. It takes into account the employment structure and work system of the discussed centers, including in terms of changing the dose limit of exposure to the eye lenses. This work complements the paper by Wrzesien (2018 Australas. Phys. Eng. Sci. Med. submitted), which focused on the exposure of workers' hands to ionizing radiation in radiopharmaceutical production centers. Measurements were carried out using high-sensitivity thermoluminescence detectors (LiF: Mg, Cu, P-MCP-N). The measurements covered 17 employees. Our results show that the highest values of personal dose equivalent Hp(3) were recorded for the F-18-FDG quality control personnel and nurses who injected the radiopharmaceutical in the patients. In the group of nurses, the maximum daily does Hp(3) reached a value close to 200 mu Sv. For staff who performed the quality control of the F-18-FDG, the maximum daily dose of Hp(3) exceeded 200 mu Sv. The estimated annual exposure of the eye lenses of workers in these two occupational groups may exceed the new dose limit (20 mSv/year). Results of this study indicate the need for optimization of the procedures related to quality control of radiopharmaceuticals and the injection of F-18-FDG in patients.
引用
收藏
页码:382 / 393
页数:12
相关论文
共 21 条
  • [1] [Anonymous], 2019, ISO ISO 4037-3
  • [2] Dose conversion coefficients for photon exposure of the human eye lens
    Behrens, R.
    Dietze, G.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (02) : 415 - 437
  • [3] Dose conversion coefficients for electron exposure of the human eye lens (vol 54, pg 4069, 2009)
    Behrens, R.
    Dietze, G.
    Zankl, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13) : 3937 - 3945
  • [4] Dose conversion coefficients for electron exposure of the human eye lens
    Behrens, R.
    Dietze, G.
    Zankl, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (13) : 4069 - 4087
  • [5] Lithium fluoride:: From LiF:Mg,Ti to LiF:Mg,Cu,P
    Bilski, P
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 100 (1-4) : 199 - 206
  • [6] Proposals for the type tests criteria and calibration conditions of passive eye lens dosemeters to be used in interventional cardiology and radiology workplaces
    Bordy, J. M.
    Daures, J.
    Denoziere, M.
    Gualdrini, G.
    Ginjaume, M.
    Carinou, E.
    Vanhavere, F.
    [J]. RADIATION MEASUREMENTS, 2011, 46 (11) : 1235 - 1238
  • [7] Reliability of eye lens dosimetry in workers of a positron emission tomography radiopharmaceutical production facility
    da Silva, Teogenes A.
    Guimaraes, Margarete C.
    Meireles, Leonardo S.
    Teles, Luciana L. D.
    Lacerda, Marco Aurelio S.
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 117 : 70 - 73
  • [8] Daures J., 2009, CEA SACLAY
  • [9] ICRU, 1992, ICRU Report 47
  • [10] International Organization for Standardization, 2000, NUCL EN RAD PROT IND