Carbon nanotubes modified with antimony nanoparticles in a paraffin composite electrode: Simultaneous determination of sulfamethoxazole and trimethoprim

被引:77
作者
Cesarino, Ivana [1 ]
Cesarino, Vivian [2 ]
Lanza, Marcos R. V. [1 ]
机构
[1] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
[2] Univ Sao Paulo, Escola Engn Sao Carlos, BR-13560970 Sao Carlos, SP, Brazil
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2013年 / 188卷
基金
巴西圣保罗研究基金会;
关键词
Antimony nanoparticles; Carbon nanotubes; Paraffin composite electrode; Antibiotics; PULSE VOLTAMMETRIC DETERMINATION; FILM ELECTRODE; ELECTROCHEMICAL DETECTION; ELECTROANALYTICAL DETERMINATION; MICROFLUIDIC DEVICE; OXIDATION;
D O I
10.1016/j.snb.2013.08.047
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new sensor has been developed for the simultaneous detection of sulfamethoxazole (SMX) and trimethoprim (TMP) using differential pulse voltammetry at a paraffin composite electrode based on multi-walled carbon nanotubes (MWCNT) modified with antimony nanoparticles (SbNPs). The morphology of the MWCNT-SbNPs nanocomposite and the electrochemical performance of the compositeelectrode were characterised by field emission gun scanning electron microscopy and cyclic voltammetry, respectively. The synergistic effect of the carbon nanotubes and the SbNPs yielded LOD of 24 nmol L-1 (6.1 mu g L-1) for SMX and 31 nmol L-1(9.0 mu g L-1) for TMP. Additionally, the simultaneous determination of SMX and TMP in natural water was achieved. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:1293 / 1299
页数:7
相关论文
共 27 条
  • [1] Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: Application to sulfamethoxazole and trimethoprim
    Almeida, S. A. A.
    Arasa, E.
    Puyol, M.
    Martinez-Cisneros, C. S.
    Alonso-Chamarro, J.
    Montenegro, M. C. B. S. M.
    Sales, M. G. F.
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 30 (01) : 197 - 203
  • [2] Simultaneous Differential Pulse Voltammetric Determination of Sulfamethoxazole and Trimethoprim on a Boron-Doped Diamond Electrode
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Cass, Quezia B.
    Fatibello-Filho, Orlando
    [J]. ELECTROANALYSIS, 2009, 21 (13) : 1475 - 1480
  • [3] [Anonymous], 1987, ANALYST, V112, P199
  • [4] Electrocatalytic oxidation and differential pulse voltammetric determination of sulfamethoxazole using carbon nanotube paste electrode
    Arvand, Majid
    Ansari, Reza
    Heydari, Lida
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2011, 31 (08): : 1819 - 1825
  • [5] Biosensor Based on Electrocodeposition of Carbon Nanotubes/Polypyrrole/Laccase for Neurotransmitter Detection
    Cesarino, Ivana
    Galesco, Heloisa V.
    Moraes, Fernando C.
    Lanza, Marcos R. V.
    Machado, Sergio A. S.
    [J]. ELECTROANALYSIS, 2013, 25 (02) : 394 - 400
  • [6] Electrochemical detection of carbamate pesticides in fruit and vegetables with a biosensor based on acetylcholinesterase immobilised on a composite of polyaniline-carbon nanotubes
    Cesarino, Ivana
    Moraes, Fernando C.
    Lanza, Marcos R. V.
    Machado, Sergio A. S.
    [J]. FOOD CHEMISTRY, 2012, 135 (03) : 873 - 879
  • [7] Real-time electrochemical determination of phenolic compounds after benzene oxidation
    Cesarino, Ivana
    Moraes, Fernando C.
    Ferreira, Tanare C. R.
    Lanza, Marcos R. V.
    Machado, Sergio A. S.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 672 : 34 - 39
  • [8] A Biosensor Based on Polyaniline-Carbon Nanotube Core-Shell for Electrochemical Detection of Pesticides
    Cesarino, Ivana
    Moraes, Fernando C.
    Machado, Sergio A. S.
    [J]. ELECTROANALYSIS, 2011, 23 (11) : 2586 - 2593
  • [9] A New Indirect Electrochemical Method for Determination of Ozone in Water Using Multiwalled Carbon Nanotubes
    Cesarino, Ivana
    Moraes, Fernando C.
    Machado, Sergio A. S.
    PassarettiFilho, Juliano
    Cardoso, Arnaldo A.
    [J]. ELECTROANALYSIS, 2011, 23 (06) : 1512 - 1517
  • [10] Antimony film electrode for stripping voltammetric measurement of Hg(II) in the presence of Cu(II)
    Dal Borgo, Sebastiano
    Jovanovski, Vasko
    Hocevar, Samo B.
    [J]. ELECTROCHIMICA ACTA, 2013, 88 : 713 - 717