High Resolution Ultrasonic Attenuation Measurement in Pulse-echo Setup

被引:0
|
作者
Dubey, P. K. [1 ]
Rajagopalan, S. [2 ]
Vyaghra, V. R. [2 ]
Pendsey, V. M. [3 ]
Sharma, S. J. [4 ]
机构
[1] Natl Phys Lab, Radio & Atmospher Sci Div, New Delhi 110012, India
[2] RSTM Nagpur Univ Campus, Dept Elect, Nagpur 440033, Maharashtra, India
[3] Sindhu Mahavidyalaya, Dept Elect, Nagpur 440017, Maharashtra, India
[4] SK Porwal Coll, Dept Elect, Nagpur 441002, Maharashtra, India
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the present work, a new technique for ultrasonic attenuation measurement in pulse echo setup is designed using off the shelf components. The technique is based on the comparison of echo amplitudes with a programmable reference voltage generated by the personal computer. The designed circuit can measure the echo amplitudes up to seven echoes with a resolution of 4mV, which is sufficient for estimation of ultrasonic attenuation. It does not require the fast analog to digital converters. A program has been developed in "C" to record echo amplitudes and display ultrasonic attenuation on screen. The instrument developed is a stand alone system and does not require any other instrument except PC. The developed technique has been tested for its functionality on some standard liquids.
引用
收藏
页码:245 / 252
页数:8
相关论文
共 50 条
  • [21] Real-time implementation of Kalman filter to improve accuracy in the measurement of time of flight in an ultrasonic pulse-echo setup
    Dubey, S. U.
    Dubey, P. K.
    Rajagopalan, S.
    Sharma, S. J.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (02):
  • [22] Improvement of axial resolution of pulse-echo ultrasonic image using the wavelet transform
    Hamamoto, K
    Nishimura, T
    Saito, M
    SIMULATIONS IN BIOMEDICINE IV, 1997, : 331 - 336
  • [23] ULTRASONIC PULSE-ECHO TECHNIQUE FOR VHF RANGE
    HEMPHILL, RB
    PENN, TC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1967, 38 (12): : 1809 - &
  • [24] A NEW FREQUENCY-SHIFT TECHNIQUE FOR INSTANTANEOUS PULSE-ECHO ATTENUATION MEASUREMENT
    HO, JSC
    SMITH, KC
    HUNT, JW
    ULTRASONIC IMAGING, 1986, 8 (01) : 52 - 53
  • [25] The use of the wavelet transform for improvement of axial resolution of pulse-echo ultrasonic image
    Hamamoto, K
    Nishimura, T
    PROCEEDINGS OF THE 1996 IEEE IECON - 22ND INTERNATIONAL CONFERENCE ON INDUSTRIAL ELECTRONICS, CONTROL, AND INSTRUMENTATION, VOLS 1-3, 1996, : 536 - 539
  • [26] PULSE-ECHO ULTRASONIC FINGERPRINT SENSOR ON A CHIP
    Tang, H.
    Lu, Y.
    Fung, S.
    Tsai, J. M.
    Daneman, M.
    Horsley, D. A.
    Boser, B. E.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 674 - 677
  • [27] HIGH-SENSITIVITY, HIGH-RESOLUTION ULTRASOUND PULSE-ECHO MEASUREMENT USING DECONVOLUTION FILTERING
    YAMADA, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1989, 28 : 257 - 259
  • [28] Investigation of frequency-dependent attenuation coefficients for multiple solids using a reliable pulse-echo ultrasonic measurement technique
    Zhang, Guangdong
    Li, Xiongbing
    Zhang, Shuzeng
    Kundu, Tribikram
    MEASUREMENT, 2021, 177
  • [29] PREDICTED ULTRASONIC RESPONSES FOR PULSE-ECHO INSPECTIONS
    TEMPLE, JAG
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1986, 28 (03): : 145 - 154
  • [30] Measurement of frequency-dependent shear wave attenuation coefficients using an oblique incidence pulse-echo ultrasonic method
    Hou, Hongyang
    Zhang, Guangdong
    Song, Yongfeng
    Li, Xiongbing
    Zhang, Shuzeng
    Kundu, Tribikram
    MEASUREMENT, 2024, 228