Patellofemoral crepitus in high flexion rotating platform knee arthroplasty

被引:5
作者
Shillington, Mark P. [1 ]
Cashman, Kara [2 ]
Farmer, Greg [1 ]
机构
[1] Redcliffe Hosp, Dept Orthopaed Surg, Brisbane, Qld 4020, Australia
[2] Univ Adelaide, Discipline Publ Hlth, Data Management & Anal Ctr, Adelaide, SA, Australia
关键词
high flexion; patellofemoral; registry; rotating platform; TKA; total knee arthroplasty; REPLACEMENTS; BEARING; COMPLICATION; SYSTEM;
D O I
10.1111/ans.12173
中图分类号
R61 [外科手术学];
学科分类号
摘要
IntroductionRecently, implant manufacturers have made modifications to currently available implants in an attempt to improve postoperative flexion. The Low Contact Stress (LCS) RPS (DePuy Orthopaedics Inc., Warsaw, IN, USA) is one such prosthesis which is a modification of the established LCS RP design. Satisfactory results have been obtained without patella resurfacing in the original LCS RP design. MethodsWe report on a single surgeon series showing an alarmingly high incidence of patellofemoral crepitus when this new prosthesis, LCS RPS, is used without patella resurfacing. In addition, the outcomes for this prosthesis from the Australian National Joint Replacement registry will be reported. These results show a high revision rate with most revisions being patella resurfacing for patellofemoral pain. ResultsAffected patients who elected to have a revision procedure underwent either an arthroscopic patellaplasty procedure or revision to resurface the patella. Both of these procedures resulted in satisfactory resolution of symptoms in the majority of patients. DiscussionPotential causes for this complication are discussed. It is the recommendation of the authors that when using this prosthesis the patella is resurfaced.
引用
收藏
页码:779 / 783
页数:5
相关论文
共 17 条
  • [1] [Anonymous], 2012, ANN REPORT
  • [2] Indications for lateral retinacular release in total knee replacement
    Archibeck, MJ
    Camarata, D
    Trauger, J
    Allman, J
    White, RE
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) : 157 - 161
  • [3] A new patellofemoral scoring system for total knee arthroplasty
    Baldini, Andrea
    Anderson, John A.
    Zampetti, Piergiuseppe
    Pavlov, Helene
    Sculco, Thomas P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 150 - 154
  • [4] Buechel FF, 2001, CLIN ORTHOP RELAT R, P41
  • [5] Cemented rotating-platform total knee replacement - A concise follow-up, at a minimum of fifteen years, of a previous report
    Callaghan, JJ
    O'Rourke, MR
    Iossi, MF
    Liu, SS
    Goetz, DD
    Vittetoe, DA
    Sullivan, PM
    Johnston, RC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (09) : 1995 - 1998
  • [6] Prospective Randomized Comparison of High-Flex and Standard Rotating Platform Total Knee Arthroplasty
    Hamilton, William G.
    Sritulanondha, Supatra
    Engh, C. Anderson, Jr.
    [J]. JOURNAL OF ARTHROPLASTY, 2011, 26 (06) : 28 - 34
  • [7] HOZACK WJ, 1989, CLIN ORTHOP RELAT R, P203
  • [8] Long-term results of low contact stress mobile-bearing total knee replacements
    Huang, CH
    Ma, HM
    Lee, YM
    Ho, FY
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (416) : 265 - 270
  • [9] Comparison of patellar retention versus resurfacing in LCS mobile-bearing total knee arthroplasty
    Hwang, Bo-Hyun
    Yang, Ick-Hwan
    Han, Chang-Dong
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (03) : 524 - 531
  • [10] THE POSTERIOR STABILIZED CONDYLAR PROSTHESIS - A MODIFICATION OF THE TOTAL CONDYLAR DESIGN - 2-YEAR TO 4-YEAR CLINICAL-EXPERIENCE
    INSALL, JN
    LACHIEWICZ, PF
    BURSTEIN, AH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) : 1317 - 1323