Dual-Channel Electrospray Microchip

被引:8
作者
Lu, Yu [1 ]
Liu, Fang [1 ]
Lion, Niels [2 ]
Girault, Hubert H. [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Stn 6, Lab Electrochim Phys & Analyt, CH-1015 Lausanne, Switzerland
[2] Serv Reg Vaudois Transfus Sanguine, Epalinges, Switzerland
基金
瑞士国家科学基金会;
关键词
Dual-channel emitter; Microchip; Micro-electrospray ionization; Mass spectrometry; MASS-SPECTROMETRY; IONIZATION;
D O I
10.1007/s13361-012-0547-z
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A dual-channel electrospray microchip has been developed for electrospray ionization mass spectrometry (ESI-MS) where aqueous samples are mixed at the Taylor cone with an organic buffer. Due to the fast and effective mixing in the Taylor cone, the aqueous sample can be well ionized with a high ion intensity. The influence of geometric parameters such as the distance between the two microchannels at their junction at the tip of the emitter has been investigated together with chemical parameters such as the organic buffer composition.
引用
收藏
页码:454 / 457
页数:4
相关论文
共 13 条
[1]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[2]   MICRO-ELECTROSPRAY MASS-SPECTROMETRY - ULTRA-HIGH-SENSITIVITY ANALYSIS OF PEPTIDES AND PROTEINS [J].
EMMETT, MR ;
CAPRIOLI, RM .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (07) :605-613
[3]   NANOELECTROSPRAY EMITTERS: TRENDS AND PERSPECTIVE [J].
Gibson, Graham T. T. ;
Mugo, Samuel M. ;
Oleschuk, Richard D. .
MASS SPECTROMETRY REVIEWS, 2009, 28 (06) :918-936
[4]  
Gobry V, 2002, PROTEOMICS, V2, P405, DOI 10.1002/1615-9861(200204)2:4<405::AID-PROT405>3.0.CO
[5]  
2-Y
[6]   On-chip protein sample desalting and preparation for direct coupling with electrospray ionization mass spectrometry [J].
Lion, N ;
Gellon, JO ;
Jensen, H ;
Girault, HH .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1003 (1-2) :11-19
[7]   Peptide-Phospholipid Complex Formation at Liquid-Liquid Interfaces [J].
Mendez, Manuel A. ;
Prudent, Michel ;
Su, Bin ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2008, 80 (24) :9499-9507
[8]   In-Spray Supercharging of Peptides and Proteins in Electrospray Ionization Mass Spectrometry [J].
Miladinovic, Sasa M. ;
Fornelli, Luca ;
Lu, Yu ;
Piech, Krzysztof M. ;
Girault, Hubert H. ;
Tsybin, Yury O. .
ANALYTICAL CHEMISTRY, 2012, 84 (11) :4647-4651
[9]   Biphasic Electrospray Ionization for the Study of Interfacial Complexes [J].
Prudent, Michel ;
Mendez, Manuel A. ;
Girault, Hubert H. .
ANALYTICAL SCIENCES, 2008, 24 (11) :1399-1404
[10]   Microfabricated dual sprayer for on-line mass tagging of phosphopeptides [J].
Prudent, Michel ;
Rossier, Joel S. ;
Lion, Niels ;
Girault, Hubert H. .
ANALYTICAL CHEMISTRY, 2008, 80 (07) :2531-2538