Combined quartz crystal microbalance with dissipation (QCM-D) and generalized ellipsometry (GE) to characterize the deposition of titanium dioxide nanoparticles on model rough surfaces

被引:20
作者
Kananizadeh, Negin [1 ,3 ]
Rice, Charles [2 ,3 ]
Lee, Jaewoong [1 ,3 ]
Rodenhausen, Keith B. [2 ,3 ,4 ]
Sekora, Derek [2 ,3 ]
Schubert, Mathias [2 ,3 ]
Schubert, Eva [2 ,3 ]
Bartelt-Hunt, Shannon [1 ,3 ]
Li, Yusong [1 ,3 ]
机构
[1] Univ Nebraska, Dept Civil Engn, Lincoln, NE 68588 USA
[2] Univ Nebraska, Dept Elect & Comp Engn, Lincoln, NE 68588 USA
[3] Univ Nebraska, Ctr Nanohybrid Funct Mat, Lincoln, NE 68588 USA
[4] Biolin Sci Inc, Paramus, NJ 07652 USA
基金
美国国家科学基金会;
关键词
Quartz crystal microbalance; Rough surfaces; Engineered nanoparticles; Nanoparticle deposition; Generalized ellipsometry; MULTIWALLED CARBON NANOTUBES; NANOSTRUCTURED SURFACES; TIO2; NANOPARTICLES; POLYMER-FILMS; HUMIC-ACID; ADSORPTION; QUANTIFICATION; RETENTION; CHEMISTRY; KINETICS;
D O I
10.1016/j.jhazmat.2016.03.048
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Measuring the interactions between engineered nanoparticles and natural substrates (e.g. soils and sediments) has been very challenging due to highly heterogeneous and rough natural surfaces. In this study, three-dimensional nanostructured slanted columnar thin films (SCTFs), with well-defined roughness height and spacing, have been used to mimic surface roughness. Interactions between titanium dioxide nanoparticles (TiO2NP), the most extensively manufactured engineered nanomaterials, and SCTF coated surfaces were measured using a quartz crystal microbalance with dissipation monitoring (QCM-D). In parallel, in-situ generalized ellipsometry (GE) was coupled with QCM-D to simultaneously measure the amount of TiO2NP deposited on the surface of SCTF. While GE is insensitive to effects of mechanical water entrapment variations in roughness spaces, we found that the viscoelastic model, a typical QCM-D model analysis approach, overestimates the mass of deposited TiO2NP. This overestimation arises from overlaid frequency changes caused by particle deposition as well as additional water entrapment and partial water displacement upon nanoparticle adsorption. Here, we demonstrate a new approach to model QCM-D data, accounting for both viscoelastic effects and the effects of roughness-retained water. Finally, the porosity of attached TiO2NP layer was determined by coupling the areal, mass density determined by QCM-D and independent GE measurements. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:118 / 128
页数:11
相关论文
共 34 条
  • [21] Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces
    Andersson, M
    Andersson, J
    Sellborn, A
    Berglin, M
    Nilsson, B
    Elwing, H
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) : 79 - 86
  • [22] Investigation of Bovine Serum Albumin (BSA) Attachment onto Self-Assembled Monolayers (SAMs) Using Combinatorial Quartz Crystal Microbalance with Dissipation (QCM-D) and Spectroscopic Ellipsometry (SE)
    Phan, Hanh T. M.
    Bartelt-Hunt, Shannon
    Rodenhausen, Keith B.
    Schubert, Mathias
    Bartz, Jason C.
    PLOS ONE, 2015, 10 (10):
  • [23] Watching cellulose grow - Kinetic investigations on cellulose thin film formation at the gas-solid interface using a quartz crystal microbalance with dissipation (QCM-D)
    Mohan, Tamilselvan
    Spirk, Stefan
    Kargl, Rupert
    Doliska, Ales
    Ehmann, Heike M. A.
    Koestler, Stefan
    Ribitsch, Volker
    Stana-Kleinschek, Karin
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2012, 400 : 67 - 72
  • [24] Quartz Crystal Microbalance with Dissipation (QCM-D) as a tool to study the interaction between whey protein isolate and low methoxyl pectin
    Setiowati, Arima Diah
    De Neve, Lorenz
    A'yun, Qurrotul
    Van der Meeren, Paul
    FOOD HYDROCOLLOIDS, 2021, 110
  • [25] Utilisation of Quartz Crystal Microbalance Sensors with Dissipation (QCM-D) for a Clauss Fibrinogen Assay in Comparison with Common Coagulation Reference Methods
    Oberfrank, Stephanie
    Drechsel, Hartmut
    Sinn, Stefan
    Northoff, Hinnak
    Gehring, Frank K.
    SENSORS, 2016, 16 (03):
  • [26] Quartz crystal microbalance with dissipation (QCM-D) as tool to exploit antigen-antibody interactions in pancreatic ductal adenocarcinoma detection
    Bianco, Monica
    Aloisi, Alessandra
    Arima, Valentina
    Capello, Michela
    Ferri-Borgogno, Sammy
    Novelli, Francesco
    Leporatti, Stefano
    Rinaldi, Rosaria
    BIOSENSORS & BIOELECTRONICS, 2013, 42 : 646 - 652
  • [27] In situ kinetics and conformation studies of dodecylamine adsorption onto zinc sulfide using a quartz crystal microbalance with dissipation (QCM-D)
    Kou, Jue
    Xu, Shihong
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2016, 490 : 110 - 120
  • [28] Meaning of xylan acetylation on xylan-cellulose interactions: A quartz crystal microbalance with dissipation (QCM-D) and molecular dynamic study
    Jaafar, Zahraa
    Mazeau, Karim
    Boissiere, Alexandre
    Le Gall, Sophie
    Villares, Ana
    Vigouroux, Jacqueline
    Beury, Nadege
    Moreau, Celine
    Lahaye, Marc
    Cathala, Bernard
    CARBOHYDRATE POLYMERS, 2019, 226
  • [29] Protein interactions and conformations on graphene-based materials mapped using a quartz-crystal microbalance with dissipation monitoring (QCM-D)
    Hampitak, Piramon
    Melendrez, Daniel
    Iliut, Maria
    Fresquet, Maryline
    Parsons, Natalie
    Spencer, Ben
    Jowitt, Thomas A.
    Vijayaraghavan, Aravind
    CARBON, 2020, 165 : 317 - 327
  • [30] A comparative study of protein adsorption on titanium oxide surfaces using in situ ellipsometry, optical waveguide lightmode spectroscopy, and quartz crystal microbalance/dissipation
    Höök, F
    Vörös, J
    Rodahl, M
    Kurrat, R
    Böni, P
    Ramsden, JJ
    Textor, M
    Spencer, ND
    Tengvall, P
    Gold, J
    Kasemo, B
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2002, 24 (02) : 155 - 170